This is a universal device that can measure packed columns and capillary columns with one unit. This is a popular machine with excellent cost-effectiveness, which combines the performance and operability of GC-2010 while inheriting the scalability of GC-14 series.
*GC-2014 won the 2005 Design Award.

The GC-2014 series comes standard with an electronic flow controller (AFC), which can digitally control the flow rate of the carrier gas in capillary and packed columns. As a result, precise flow control can be achieved, and the impact of environmental temperature changes is as small as 1/10 of the GC-14 series and 1/3 of the GC-17 series, thus achieving good reproducibility and resettability even in capillary analysis. Possible fluctuations in area and retention time are approximately one-third of those in the GC-14 series.
In addition, according to the structure of GC-2010 with FID, FPD, and FTD detectors, the performance of capillary analysis (small detection sensitivity, etc.) is superior to GC-17A. In addition, FPD uses a new type of FPD that supports both capillary and packed columns.

A large display screen allows you to check the baseline and chromatogram on the LCD.
It has productivity enhancing features such as pop-up screens and help functions to prevent accidental operations.
You can also use the self diagnostic function to confirm that the device is functioning properly and prevent unexpected shutdowns by performing routine diagnostics.

The large oven can easily replace the chromatography column
According to the analysis purpose and target components, four types of injection units and five detectors can be selected, and three types of injection units and four detectors can be installed simultaneously.
In addition, Shimadzu GC series GC-7, 9, 12, 14, 15, 16 series glass packed columns can be used to effectively utilize chromatographic column assets.
Even if I try to update GC-14A/B to GC-2014, it cannot be installed due to the excessive depth of GC-2014. To address this situation, we have prepared a shorter depth model GC-2014S. The width of GC-2014S is 40 centimeters and the depth is 54 centimeters, which is very suitable for the installation space of GC-14A/B.

Shimadzu SHIMADZU gas chromatograph GC-2014 from Japan
Shimadzu SHIMADZU gas chromatograph GC-2014 from Japan