Renishaw's laser device has high-performance measurement capabilities based on the principle of laser interference, and is as easy to install as traditional steel grating and glass grating.
The RLE system is a zero difference laser interferometry measurement system designed specifically for position feedback applications. Each RLE system includes an RLU laser device and one or two RLD10 emission heads, depending on the specific application requirements.
The RLU laser device is available in two configurations: single axis or dual axis, including a HeNe (helium/neon) laser source, electronic devices for frequency stabilization, fiber optic conduction devices, and axis position feedback electronic devices.
With the help of Renishaw laser rulers, we are able to exceed the standards set by our customers and strive to provide them with the best possible experience; And the reason why we are able to continuously achieve success is partly attributed to the technological advancements brought by Renishaw.
Aerotech (USA)
00:22
Renishaw currently offers two models of laser devices, which differ in performance:
The laser frequency stabilization accuracy of RLU10 within any hour is ± 50 ppb, and its performance level is suitable for most non vacuum environment applications.
Combining RLU10 with a Renishaw launch head (RLD) suitable for the desired application has the following characteristics and advantages:
| fiber length | 3 meters or 6 meters* |
| axle count | Uniaxial or biaxial* |
| laser source | Type 2 helium neon (HeNe) laser |
| output | Analog/Digital Orthogonal |
| speed | Up to 2 m/s** |
*Factory configuration
**Depending on the model/resolution
Laser frequency stabilization accuracy (1 minute) |
‹±10 ppb |
Laser frequency stabilization accuracy (1 hour) |
‹±50 ppb |
Laser frequency stabilization accuracy (8 hours) |
‹±50 ppb |
Vacuum wavelength stability (over 3 years) |
±0.1 ppm |
Are you looking for a laser ruler suitable for XY platform applications in non vacuum environments? RLE10-DX-XG is an ideal choice for this type of application, which uses RLU10 laser device and two RLD10-A3-P9 (plane mirror interferometer 90 °) emission heads.
The laser frequency stabilization accuracy of RLU20 within any hour is ± 2 ppb, which can provide excellent measurement performance for most vacuum environment applications.
Combining RLU20 with a Renishaw launch head (RLD) suitable for the desired application has the following characteristics and advantages:
| fiber length | Only 3 meters* |
| axle count | Uniaxial or biaxial* |
| laser source | Type 2 helium neon (HeNe) laser |
| output | Analog/Digital |
| speed | Up to 2 m/s** |
*Factory configuration
**Depending on the model/resolution
| Laser frequency stabilization accuracy (1 minute) | ‹±1 ppb |
| Laser frequency stabilization accuracy (1 hour) | ‹±2 ppb |
| Laser frequency stabilization accuracy (8 hours) | ‹±20 ppb |
| Vacuum wavelength stability (over 3 years) | ±0.1 ppm |
Are you looking for a laser ruler suitable for relative measurement applications in a vacuum environment? The RLE20-DX-XP is an ideal choice for this type of application, which uses an RLU20 laser device and two RLD10-X3-DI (differential interferometer) emission heads.
To operate as a displacement interferometer, Renishaw's laser device needs to be connected to a suitable laser head. When defining an RLE system, the following options should be considered:
To determine the order number for the RLE laser ruler system required for your specific application, simply input your application requirements into the order number generator. It will automatically calculate the necessary system order number, which can be used for inquiries or placing orders.