Welcome Customer !

Membership

Help

Shanghai Xuyue Intelligent Technology Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products
Product Categories

Shanghai Xuyue Intelligent Technology Co., Ltd

  • E-mail

    976009413@qq.com

  • Phone

    13817773545

  • Address

    Minhang District, Shanghai

Contact Now

Supply of Carl Humidifier Barrel BLCT1C00W2/BLCT1COOW2

NegotiableUpdate on 01/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Our company supplies a full range of products including Italian Carl air conditioners, humidifiers, and freezers, including BLCT1C00W2/BLCT1COOW2. Provide technical support such as selection, quotation, and after-sales service for *. $r $n Details: Our sales engineer, Mr. Sun

Product Details

Supply of Carl Humidifier Barrel BLCT1C00W2/BLCT1COOW2

Certified water droplet separator for AHU (UAKDS *, SPFR *), capable of intercepting water that has not yet evaporated

The purpose of droplets is to prevent them from running out of the humidification room. The water droplet separator is supplied with standard modules, and its assembly can be completed

Fully covering the cross-section of AHU. The width and length of the water droplet separator are multiples of 152mm. There are two types of water droplet separators: fiberglass or AISI304 steel filter material, the latter of which is necessary for devices that comply with VDI6022 certification. The pressure drop is very small, and when the wind speed reaches 3.5-4 m/s, it varies from 30 Pa (when dry) to 70 Pa (when wet). The frame of the water droplet separator is usually made of stainless steel and can ensure fast and effective drainage.

water quality requirements

To ensure proper operation, the humiFog multi zone system should use water that has been demineralized (conductivity range 0~50 µ S/cm). To meet water quality requirements, a reverse osmosis system is usually required for treating tap water. The working principle of this system is to transport water to a special filtration membrane, which can only permeate molecules of the same size as water molecules, thereby removing almost all minerals and salts present in the water. It can also serve as a physical bacterial barrier, and reverse osmosis water treatment can remove mineral salts, making the maintenance requirements inside the air duct only simple regular inspections!

System Composition

Water pump components with continuous adjustment (using frequency converter);

Glass fiber or stainless steel water droplet separators, mandatory hygiene certification requirements;

Regional controller (referring only to multi zone humidification)

High pressure connecting pipeline;

Water treatment system (reverse osmosis system).

controller

A simple and intuitive user interface with a large display screen can display easy to understand information, even if the user does not have a detailed understanding of the product. This user interface can display 5 languages (Italian, English, French, German, and Spanish),

And you only need to use buttons with icons to browse the menu.

Spray rack customized based on AHU

Supply of Carl Humidifier Barrel BLCT1C00W2/BLCT1COOW2

Room allocation system

(UAKC*FP*)

Composed of stainless steel manifolds with nozzles, installed in rooms that are humidified or cooled. There are multiple models of this nozzle, which can be installed on only one side or on opposite sides simultaneously. In the distribution system, multiple nozzles are connected in series to form a circuit. The stainless steel manifold is 2450mm long with an outer diameter of 16mm. Each distribution line can be directly connected to the pump station device or controlled by an electromagnetic switch valve. By controlling these solenoid valves, humifog can control the humidification of the distribution system

The quantity can be adjusted step by step to achieve humidification (up to 6 steps). Each distributor pipeline has a drainage valve, mainly used to quickly release water pressure when the distributor pipeline stops atomization: when the drainage valve is opened, the pressure will quickly drop from 70 bar to 0,

The distributor pipeline has been emptied to prevent nozzle dripping. In addition, the drain valve can also be used for regular automatic cleaning cycles

The environment is controlled and managed by Humifog. The on-off solenoid valve is made of stainless steel material and has a normally closed pressure

The maximum pressure is up to 100 bar, while the normally open valve automatically opens at a pressure of approximately 15 bar: both connections are 1/8 "F GAS.

Liquid Teflon

(5024612AXX) Liquid Teflon is used for sealing high-pressure water connectors, with 100ml per package.

It is used to seal the nozzle and all spray supports and the joints of the steam blowers pre installed by CAREL.

The solenoid valve junction box is used to install the solenoid valve on the atomization bracket inside the air duct. There are different models available for installing 4-8 solenoid valves.

The humidifier with a humidification capacity of 2-10kg/h is equipped with a cylindrical stainless steel humidification bucket, which is easy to disassemble and clean. Humidifiers with large humidification capacity, 20-60kg/h, have a stainless steel humidification bucket with a rectangular base and a large opening (front or top) for easy maintenance without removing the humidification bucket.

Product advantages:

Extremely precise, capable of achieving ± 1% rH;

The electric heating element is embedded in corrosion-resistant lightweight alloy castings to ensure good thermal conductivity and reliability. (CAREL method)

Inserting a temperature sensor into the electric heating element to prevent overheating can effectively detect any scale deposits that need to be cleaned in advance. (CAREL method)

The electric heating element covered with Niflon anti stick coating (advanced configuration type) is very easy to clean;

Humidifiers with H-type and T-type control modes, equipped with solid-state relays, allow continuous adjustment of steam production from 10% of rated steam production, with very precise control. The humidifier with C-type control mode can operate in an on/off mode;

The "anti foam" system detects foam to prevent any water drop from releasing together with steam;

H-type control supports a second restriction sensor to prevent the formation of any condensation water in the air duct (more hygienic);

Humidifiers with H-type and T-type control modes have preheating function and can respond quickly to steam production requirements;

Humidifiers with H-type control mode can also control dehumidification equipment.

For air supply steam distributors, a 7mm condensate drain hose must be used to remove condensate water from the steam distributor, while for "DP" linear steam distributors used in air ducts, a 10mm condensate drain hose is used to remove cold water from the steam distributor

Condensed water. All kinds of isothermal humidifiers use the same drainage pipe, which is made of rubber and can withstand high temperatures of up to 100 ° C.

The high-pressure micro mist humidifier utilizes the potential of water by delivering water at high pressure (usually 70 bar) through a specific volumetric pump, thereby obtaining very fine and uniform atomized water through a special nozzle. The most commonly used application of these humidifiers is in air treatment units, where pressurized water distribution systems are installed. In industrial environments where wood and paper products are processed, or in the textile industry, this humidification system is commonly used to directly introduce atomized water into the room. In terms of humidity control, high-pressure mist humidifiers are also a solution for industrial facilities and large public spaces, such as train stations and airports in big cities, inside air handling units or rooms. They can fully utilize the potential provided by evaporative cooling, either directly or indirectly. An important aspect is that high-pressure mist humidifiers must meet hygiene requirements in the applications they are used in. The management of the cleaning cycle, the materials used, and the setting of the atomized water distribution system are the main features to ensure that CAREL humidifiers comply with the strictest mandatory hygiene regulations (VDI6022).

Supply of Carl Humidifier Barrel BLCT1C00W1/BLCT1COOW1

Common humidification bucket models

BL0T1C00H0 380V 3KG/H

BL0T2C00H0 380V 8KG/H

BL0T2B00H0 380V 8KG/H

BL0T3C00H0 380V 15KG/H

BL0T4C00H0 380V 45KG/H

BLCT2B00W0 380V 8KG/H

BLCT2C00W0 380V 8KG/H

BLCT3B00W0 380V 15KG/H

BLCT3C00W0 380V 15KG/H

BLCT4D00W0 380V 45KG/H

BLCT4C00W0 380V 45KG/H

BLCT4B00W0 380V 45KG/H

BL0SRF00H1

BLOSRF00H1

BL0S1F00H1

BLOS1FOOH1

BLCT2C00W2

BLCT2COOW2

BLCT2B00W2

BLCT2BOOW2

BLCT2D00W0

BLCT2D00W2

BLCT2DOOW2

BLCT5C00W0

BLCT5COOWO

BLCS1E00W2

BLCS1EWPW2

BLCS1F00W2

BLCS1FWPW2

BLCT1A00W1

BLCT1AOOW1

BLCT1A00W2

BLCT1AWPW1

BLCT1B00W1

BLCT1BOOW1

BLCT1B00W2

BLCT1BOOW2

BLCT1C00W1

BLCT1COOW1

BLCT1C00W2

BLCT1COOW2

BLCT1CWPW1

BLCT1CWPW2

BLCT1D00W1

BLCT1DOOW1

98CT2BMPW0

98CT2DMPW0

9BCT2DMWO

BLCS2E00W2

BLCS2EWPW2

BLCSF00W0

BLCS2FWPW0

BLCT2A00W2

BLCT2AWPW2

BLCT2B00W0

BLCT2BOOWO

BLCT2B00W2

BLCT2BOOW2

BLCT2BWPW0

BLCT2BWPWO

BLCT2BWPW2

BLCT2C00W0

BLCT2COOWO

BLCT2COOW2

BLCT2C00W2

BLCT2CWPW0

BLCT2CWPWO

BLCT2CWPW2

BLCT2D00W0

BLCT2DOOWO

BLCT2D00W2

BLCT2DOOW2

BLCT2DWPW0

BLCT2DWPWO

BLCT2DWPW2

Abandoned humidifier bucket

BL0TAR00H1 BLOTRAOOH1 BL0T2A00H0 BLOT2AOOHO BL0T3A00H0 BLOT3AOOHO

BL0T4B00H0 BLOT4BOOHO

BL0TRC00H1 BLOTRCOOH1 BL0T1A00H1 BLOT1AOOH1 BL0T2B00H0 BLOT2BOOHO

BL0T4C00H0 BLOT4COOHO BL0T4B00H0 BLOT4BOOHO

BL0TRD00H1 BLOTRDOOH1 BL0T1C00H1 BLOT1COOH1 BL0T2C00H0 BLOT2COOHO

BL0T3C00H0 BLOT3COOHO BL0T4D00H0 BLOT4DOOHO BL0T4C00H0 BLOT4COOHO

BL0TRDL00H1 BLOTRDOOH1 BL0T1B00H0 BKOT1BOOH1 BL0TRMC0H1

BL0T1D00H1 BLOT1COOH1

Openable humidifier bucket

BLCTRA00W1 BLCTRAOOW1 BLCT1A00W1 BLCT1AOOW1 BLCT2A00W0 BLCT2AOOWO

BLCT3A00W0 BLCT3AOOWO BLCT4B00W0 BLCT4BOOWO BLCTRB00W1 BLCT2B00W0 BLCTRC00W1 BLCT1B00W1

BLCT2B00W0 BLCT2BOOWO BLCT2C00W0 BLCT2VOOWO

BLCT3B00W0 BLCT3BOOWO BLCT3C00W0 BLCT3COOWO

BLCT4D00W0 BLCT4DOOWO

BLCT2B00W2 BLCT2BOOW2 BLCT2C00W2 BLCT2COOW2

BLCT3B00W2 BLCY3BOOW2 BLCT4B00W2 BLCT4BOOW2

BLCT4C00W2 BLCT4COOW2 BLCT5C00W2 BLCT5COOW2