Welcome Customer !

Membership

Help

Shanghai Guiyong Electronics Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Price of laboratory triple steam distillation device GY-FSZLY

NegotiableUpdate on 01/23
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The Shanghai Guiyong GY-FSZLY-6 steam distillation apparatus is one of the important methods for separating and extracting active ingredients from samples. Its operation involves introducing water vapor into the sample system, and the active ingredients are evaporated along with the water vapor to achieve the purpose of separating and purifying the active ingredients. It is widely used in various industries such as tobacco, food, pharmaceuticals, and chemical engineering. The existing traditional steam distillation equipment is a relatively cumbersome glass device, which is difficult to install, time-consuming to operate, consumes a lot of energy, and has technical problems such as safety hazards. Price of laboratory triple steam distillation device GY-FSZLY

Product Details

Zhengzhou Trace Sample Distiller, Steam Distiller,Six way multifunctional distiller GY-FSZLY

Product Introduction
Steam distillation is the last step in our entire distillation series and a commonly used method for separating and purifying organic compounds. When the mixture contains a large amount of resin like or tar like impurities, or when a certain component in the mixture has a high boiling point, decomposition occurs during ordinary distillation. It is difficult to separate them using ordinary distillation, recrystallization, and other methods. In addition, when separating adsorbed liquids from a large number of solids, steam distillation can be used for separation. Shanghai Guiyong GY-FSZLY-6Steam distillation apparatus, is one of the important methods for separating and extracting active ingredients from samples. Its operation involves introducing water vapor into the sample system, and the active ingredients are evaporated along with the water vapor, thereby achieving the purpose of separating and purifying the active ingredients. It is widely used in various industries such as tobacco, food, pharmaceuticals, and chemical engineering. The existing traditional steam distillation equipment is a relatively cumbersome glass device, which is difficult to install, time-consuming to operate, consumes a lot of energy, and has technical problems such as safety hazards.Price of laboratory triple steam distillation device GY-FSZLY

Technical Specifications
Model: GY-FSZLY-6
Display mode: LCD color screen
Heating method: Far infrared ceramic heating (no open flame heating, waterproof)
Anti backflow suction: Yes
Water vapor output: Continuous and stable automatic output of six channels of water vapor, with automatic water replenishment design for water shortage to prevent dry burning
Distillation endpoint control: Single well quantitative distillation can be set, automatic locking of distillation endpoint, control accuracy ± 2ml
Temperature control: Single hole independent adjustment of heating power (knob type)
Number of distillation units: 6 individual far-infrared ceramic heating holes
Distillation flask specifications: standard: 500ml x 6; 250ml x 6 (optional)
Distilled liquid receiving bottle: standard configuration: 250ml x 6; 100ml x 6 (optional)
Rated power: 3500W
Rated voltage: 220V/50HZ
Dimensions (mm): 960 * 575 * 410
Leakage protection device: Yes
Cooling method: The host has a built-in compressor cooling circulation system, which does not require external tap water or an external cooling water circulation machine;
Scope of application: Pre distillation treatment projects for residual sulfur dioxide in traditional Chinese medicine (ion chromatography), sodium acetate, sodium propionate, calcium propionate, etc

Main features
The intelligent steam generator is matched with the intelligent integrated distillation apparatus to perfectly solve various operational drawbacks of current steam distillation;
The collection of distillate can achieve automatic quantitative design, with a range of 0-1000ml, and automatic locking at the end of distillation;Price of laboratory triple steam distillation device GY-FSZLY
The cooling system adopts a built-in compressor self circulation system, which can start automatic internal circulation with one click;
Paired with an intelligent integrated distillation apparatus, it can achieve work linkage, and automatically stop steam heating after distillation is completed;
Large screen LCD touch screen design, easy and convenient operation.
The intelligent steam generator is equipped with six channels and a high-efficiency steam production device that can be controlled by a single hole, ensuring continuous and stable output;
The intelligent steam generator is equipped with a pure water tank, which can automatically replenish water in case of water shortage to prevent dry burning;
Intelligent steam generatorEquipped with ultra-high temperature alarm design;

Steam Distillation Device | Intelligent Steam Distillation Device | Fluoride Distillation Device | Manufacturer's Price for Fluoride Distillation Device


② Clean the thermometer promptly after use. Newly used high-temperature thermometers should not be immediately rinsed with cold water. Attention: A thermometer suitable for the measurement range should be selected. It is strictly prohibited to use thermometers beyond the range. ② When measuring the temperature of a liquid, the glass bulb of the thermometer should be immersed in the liquid but not in contact with the container wall. When measuring the temperature of steam, the glass bulb should be above the liquid level. When measuring the temperature of distilled fractions, the glass bulb should be slightly lower than the branch pipe of the distillation flask. ③ When reading, the line of sight should be level with the liquid column meniscus point (mercury thermometer) or point (alcohol thermometer). ④ Do not use a thermometer instead of a glass rod for mixing. After use, it should be wiped clean and placed in a paper sleeve. Store the medicine spoon away from heat sources for using powder or small granular solid drugs. After each use, wipe the medicine spoon clean with a clean filter paper. Precautions: Depending on the amount of reagent used, the medicine spoon should be of appropriate size. ② Do not use a medicine spoon to take hot drugs, and do not come into contact with acidic or alkaline solutions. ③ After taking the medicine, the spoon should be wiped clean with paper in a timely manner. ④ The medicine spoon specialized spoon, made of a glass rod, can be stored in small wide mouthed bottles containing solid reagents without the need for each wash. The use of powdered drugs can be done with a spoon (or paper slot), and the operating procedures are: "one slope, two feeds, three upright"; The specific operation is: first tilt the test tube, carefully insert the medicine spoon (or paper slot) containing the medicine into the bottom of the test tube, and then make the test tube stand upright. The principle of use: the "three no's" principle, namely "not smell, not touch, and not taste"; Specifically, do not smell the smell of the medicine, do not touch the medicine with your hands, and do not try the smell of the medicine ② The principle of conservation, which means strictly following the prescribed dosage of drugs in the experiment; When the dosage is not specified, it is generally taken in small amounts, and the solid only needs to cover the bottom of the test tube The principle of "three noes and one requirement" refers to the handling method of surplus drugs Specifically, it cannot be returned to the original bottle, discarded at will, or taken out of the laboratory or placed in a container.
(6) The homogenizer and homogenizer bag should be placed in a cool and dry place, especially the homogenizer bag should be kept away from acid, alkali, and sunlight to prevent premature brittleness and aging. (7) After using the homogenizer, turn off the power and clean its inside and outside first. (8) For some samples that are prone to clogging the pipette or pipette tip after tapping and homogenization, it is recommended to use sterile homogenization bags with filter screens. Common glassware: ① Culture dish (petri dish): Used to hold solid culture medium, it is the main vessel for cultivating and observing microorganisms. The general diameter is 9 centimeters. Several can be prepared according to the scale of the event. ② Test tube: Used to hold inclined culture medium (solid), it is the main vessel for inoculating microorganisms. There are two commonly used types. The larger one measures 220 millimeters in length and 20 millimeters in diameter; The smaller one is 150 millimeters long and 15 millimeters in diameter. You can choose one of them as needed and prepare several. ③ Cone flask: used to hold liquid culture medium. It is the main vessel for cultivating microorganisms using liquid culture medium. The general capacity is 50, 100, 250, 300, 500, 1000 milliliters. You can choose and prepare according to the needs of the activity. ④ Measuring cylinder and cup: used for quantitatively measuring various liquids. ⑤ Pipette (pipette): generally with capacities of 0.5, 1, 5, 10 milliliters, etc., can be selected and prepared according to needs. ⑥ Others: beakers, funnels, etc. Attention: The above introduces the basic instrument configuration of the microbiology laboratory. When setting up the laboratory, other consumables such as test tube racks, sterile sampling and weighing bags, inoculation rings, triangular bottles, measuring cylinders, defatted cotton, gauze, test tube baskets, glass test tubes, sterilization straws, drying racks, scissors, tweezers, filters, etc. are also required.
Distillation explosion boiling? Is the distillation efficiency too slow? Vacuum pump outlet leakage, laboratory odor? Is the heating pot heating up too slowly? I believe many of our friends have encountered these headache problems during our actual distillation process. So how can we avoid these problems? Today, I would like to share my experience with you. We can start by avoiding the source of purchasing a rotary evaporator. Before choosing a rotary evaporator, ask yourself the following question: What is the amount of distillation per cycle? How many samples need to be distilled per day? What are the expected solvents for distillation? What is the approximate boiling point range of solvents? Are these solvents flammable, explosive, or toxic and harmful? Once the experimental requirements and solvent type for distillation are determined, we can start purchasing a rotary evaporator! Clarify the specifications of rotary evaporators. The specifications of rotary evaporators are usually distinguished by the volume of the evaporation bottle, and the size of the required evaporation bottle depends on the amount of evaporated material. Generally speaking, 2L, 3L, and 5L rotary evaporators are suitable for small-scale laboratory experiments; 5L, 10L, and 20L are suitable for pilot testing; 20L and 50L are suitable for pilot testing and production. Of course, in special circumstances, we can also use a continuous feed tube to expand the volume of the evaporator bottle, thereby increasing the continuous distillation volume to a certain extent. The distillation efficiency of the rotary evaporator is crucial in determining the required distillation tasks. The distillation efficiency of the rotary evaporator determines the number of samples that can be distilled per day. Under the same solvent conditions, the higher the distillation efficiency, the more samples can be distilled. If the sample size is large, we need to put more effort into considering the distillation efficiency. Distiller is a device that uses electricity to heat tap water to produce pure water. By heating distilled water to produce steam and condensing it into distilled water, it can be used in pharmaceutical, formulation, laboratory, laboratory and other departments. This article introduces the working principle and usage method of a distilled water purifier. Various distilled water purifiers use the principle of liquid liquefying when it encounters heat and cold to prepare distilled water. The user should open the water inlet and ensure that the water in the evaporator reaches the standard level before closing it. After powering on, turn on the waterproof to allow distilled water to flow into the container. The distilled water dispenser should be connected to the external circuit with different power connection methods. The correct wiring method in various situations: the fuse is blown. This type of malfunction occurs frequently, and there must be a short circuit. After a power outage, the resistance range of a multimeter can be used to measure whether the heating wires of each electric heating tube are grounded. If they are grounded, their two ends can be removed as an emergency measure. The distiller is still usable, but the power is reduced,