Product Name: Power Consumption Monitoring System (PEMS) Product Model: TY-GK01 Product Overview A System Introduction TY-GK01 Power Consumption Monitoring System ..
Introduction to System A
TY-GK01 working condition electricity monitoring system (abbreviated as TY-GK01)PEMS)This is a comprehensive system independently developed by Tianjin Tongyang Technology Development Co., Ltd. for real-time monitoring and unified management of industrial enterprise emissions, pollution production, and production stoppage and restriction. This system relies on electricity monitoring technology, data analysis technology, and Internet of Things technology to achieve real-time detection of the operating conditions and electricity consumption of pollution generation, discharge, and treatment facilities of electricity consuming enterprises. Through data collection and analysis, early warning, production load analysis and other technologies, it assists government management departments in real-time grasping the operation status, pollution control and emission situation, pollution source shutdown and production restriction, and off peak production situation of production facilities and treatment facilities of various industrial enterprises, and enhances the government's execution of emergency plans for heavy pollution weather and off peak production plans.
Characteristics of System B
·Adopting an integrated design, the product circuit board and wiring terminals meet the protection level requirements of the installation site;
·Low power consumption, large storage design, historical data is not lost in case of power failure;
·Capable of power-off endurance, with a minimum endurance time of 24 hours;
·Equipment monitoring parameters include voltage, current, power, electrical energy, and other information, which can be expanded according to on-site needs;
·The device adopts technologies such as GPRS/4G wireless network for platform communication; Support uploading data from one host to multiple platforms simultaneously;
·The device runs automatically when turned on, and can automatically resume operation and support breakpoint resume when there is a power outage or the device restarts;
·The monitoring terminal can be calibrated according to the platform time to ensure clock synchronization with the system platform;
·The device host has active alarm functions such as box opening alarm, device fault alarm, and device operation status alarm;
·Support on-site data display, setting, and querying configuration parameters, limit parameters, communication parameters, etc
·Optional temperature and humidity sensors are available for precise monitoring of cable temperature and ambient temperature.
monitoring parameters
single/Three phase current, single/Three phase voltage, active power/Reactive power, power factor, electricity quantity, power quality, etc
Scope of application
This system is applied to the electrical energy monitoring of all pollution generating and pollution control equipment in pollution source emission enterprises.
·Pollution generating equipment: equipment that produces waste gas and sewage during the production process.
·Pollution control equipment: equipment required to remove pollutants from exhaust gas and sewage using physical, chemical, and/or biological methods
Technical Specifications
| module | function | parameter |
| Monitoring of electrical parameters | Operating Temperature | -20℃~80℃ |
| Operating Humidity | 5%~95% |
| measure voltage | 220V/380V single/three-phase |
| measure current | 5A - 2000A |
| data transmission | RS485、2G/4G、NB-I0T、LORA |
| Data collection and transmission | Product Model | TY-003 |
| serial port | 8-way RS-232, 1-way RS-485, with isolation |
| network communication | Wireless 4G full network, wired Ethernet 10M/100M adaptive |
| Working Voltage | 220V,50Hz |
| Operating Temperature | -20℃~80℃ |
| Operating Humidity | 5%~95% |
| Installation method | wall-mounted |