E-mail
2524300166@qq.com
-
Phone
18015580277
-
Address
No. 55 Dongfu Road, Suzhou Industrial Park
Suzhou Yucheng Instrument Co., Ltd
2524300166@qq.com
18015580277
No. 55 Dongfu Road, Suzhou Industrial Park
AWA6291 Real time Signal AnalyzerIt is a pocket sized real-time analyzer for digital signal processing technology, which can perform spectrum and amplitude analysis on noise, vibration, or other electrical signals. Modular design allows users to choose different software to achieve different functions and obtain different measurement indicators. This instrument can be applied in industrial enterprises, environmental protection, labor hygiene, scientific research and teaching, measurement and testing, and other fields to complete the measurement and analysis of machine and equipment noise, environmental noise measurement, sound power level measurement, building acoustics measurement, and measurement and analysis of machine vibration.
AWA6291 Real time Signal Analyzertechnical parameters
| signal input | Socket: X9-6z, optional LEMO socket; Input impedance: 150k Ω//100pF; large input voltage: 10V (effective value) |
| frequency range | 10Hz~20kHz(±0.2dB); 1Hz~23kHz(±1.0dB) |
| Range gain | -10dB、0dB、10dB、20dB、30dB、40dB |
| Self generated noise voltage | Less than 4 μ V (1Hz~23kHz) |
| Voltage measurement range | 15 μ V~10V (effective value) |
| signal output | Socket: Φ 3.5 stereo headphone socket; Output impedance: 1k Ω; large output signal voltage: 3.2V |
| Linear range | Greater than 90dB |
| A/D bits | 24 digits |
| sampling frequency | 48kHz |
| monitor | 240 × 160 dot matrix LCD with EL backlight |
| output interface | RS232 interface, can be connected to a micro printer to print measurement results, and can also be connected to a PC to send measurement results and real-time analysis results. USB interface, mini B type, compliant with USB1.1, compatible with USB2.0, can be connected to a PC |
| data store | The measurement results are saved in 48Mbit FLASH or the data can be transferred to a USB drive |
| Internal calendar clock | Error less than 1 minute/month |
| working power supply | 6 LR6 alkaline batteries or rechargeable batteries, can also be powered by an 8V external power source |
| Overall dimensions | 210×90×38(mm) |
| quality | 0.5kg |
| Electromagnetic Compatibility | Meet the requirements of IEC 61672.1:2002 standard for Class X sound level meters |
| working environment | Working temperature: -10 ℃ to+50 ℃; Relative humidity: 25% to 90%; Atmospheric pressure: 65kPa~108kPa |
Performance indicators of noise statistical analysis module:
| Main functions | Noise statistical analysis, 24-hour automatic monitoring, and integrated measurement |
| Main measurement indicators | Statistical Analysis Menu: LAFp、LAfmax、LAF5、LAF10、LAF50、LAF90、LAF95、LAFmin、SD、LAeq1s、LAeq,T、LAE、LAFeqT24-hour measurement menu: In addition to all measurement indicators in the statistical analysis menu, there is also Ld、Ln、Ldn |
| display resolution | 0.1dB |
| data store | Can store statistical analysis results, 24-hour measurement results, integration measurement results, up to 12288 sets, and can also transfer measurement results to a USB flash drive |
Noise 1/1 OCT analysis module performance indicators:
| Main functions | Real time octave frequency spectrum analysis and integral measurement of noise |
| Filter type | Parallel (real-time) octave band digital filter |
| Filter center frequency | 16Hz~16kHz |
| The filter meets the standard | GB/T3241 and IEC61260 Level 1 |
| Main measurement interface | List interface, graphical interface. It can display the sound pressure levels of 11 center frequencies and the weighted sound pressure levels of A, C, and Z simultaneously |
| Main measurement indicators | Instantaneous sound pressure level in frequency band (Lfmi)Frequency band 1-second equivalent sound level (L)fmeq,1s)Frequency band equivalent continuous sound level (L)fmeq,T)High weighted sound level within 1 second (L)xyp)Instantaneous weighted sound level (Lxyi)1 second equivalent weighted sound level (L)xeq,1s)Equivalent continuous weighted sound level (L)xeq,T)Sound Exposure Level (LAE), Sound Exposure Level (E), Peak C-Level (C)peak)Measure the time elapsed (Tm). (fm is determined by the center frequency, X is the frequency weighting A, C, Z; Y represents time weighting F, S, I) |
| Real time analysis speed | Approximately 47 times per second, simultaneously completing all center frequency and A weighting, C weighting, Z weighting measurements |
| Recording function | The frequency spectrum of the octave band can be recorded over time at intervals of 31ms, 0.1s, 0.5s, and 1s |
| data store | It can store the instantaneous value, 1-second integral value, integral value, large value, and total value analysis of harmonic band analysis, with up to 12288 sets of integral measurement results. The measurement results can also be transferred to a USB flash drive |
Noise 1/3 OCT analysis module performance indicators:
| Main functions | Real time 1/3 octave frequency spectrum analysis and integral measurement of noise |
| Filter type | Parallel (real-time) 1/3 octave band digital filter |
| Filter center frequency | 12.5 Hz~20 kHz |
| meet the standard | GB/T3241 and IEC61260 Level 1 |
| Main measurement interface | List interface and graphical interface, capable of simultaneously displaying the frequency band sound pressure levels of 34 center frequencies, as well as the synthesized A, C, and Z weighted sound pressure levels |
| Main measurement indicators | Instantaneous sound pressure level in frequency band (Lfmi)Frequency band 1-second equivalent sound level (L)fmeq,1s)Frequency band equivalent continuous sound level (L)fmeq,T)High weighted sound level within 1 second (L)xyp)Instantaneous weighted sound level (Lxyi)1 second equivalent weighted sound level (L)xeq,1s)Equivalent continuous weighted sound level (L)xeq,T)Sound Exposure Level (LAE), Sound Exposure Level (E), Peak C-Level (L)Cpeak)Measurement of Time of Experience (Tm) (fm is determined by the center frequency, X is A, C, Z, W-U; Y is F, S, I) |
| Recording function | The frequency spectrum of 1/3 octave band can be recorded over time at intervals of 31ms, 0.1s, 0.5s, and 1s |
| data store | Can store 1 second integral value, integral value, and total value analysis integral measurement results for 1/3 octave band analysis, up to 12288 sets, and can also transfer measurement results to a USB flash drive |
Performance indicators of noise FFT analysis module:
| Main functions | Real time FFT spectrum analysis of noise |
| number of spectral lines | 512 lines, showing 200 spectral lines |
| sampling frequency | 48kHz、24kHz、12kHz、6kHz、3kHz、1.5kHz |
| Analyze the upper limit of frequency | 18.75kHz、9375Hz、4687Hz、2344Hz、1172Hz、586Hz |
| bandwidth | 93.75Hz、46.875Hz、23.438Hz、11.74Hz、5.8594Hz、2.9297Hz |
| overlap rate | 0%, 50%, 75%, 87.5%, 93.75%, 97% |
| Average method | Exponential average F (time constant 125ms) and S (time constant 1s), and linear average |
| Main measurement indicators | F-weighted instantaneous value, S-weighted instantaneous value, 1-second equivalent sound level, and equivalent continuous sound level under each spectral line; Large weighted sound level within 1 second (Lxyp)Instantaneous weighted sound level (Lxyi)1 second equivalent weighted sound level (L)xeq,1s)Equivalent continuous weighted sound level (L)xeq,T)Sound Exposure Level (LAE), Sound Exposure Level (E), Peak C-Level (C)peak)Measurement of Time of Experience (Tm) |
| data store | Capable of storing F-time weighted instantaneous values, S-time weighted instantaneous values, 1-second integral values, and integral values for FFT analysis; The instantaneous values and integral measurement results of the total value analysis have an additional 12288 sets, and the measurement results can also be saved to a USB flash drive |
Vibration 1/3 OCT analysis module performance indicators:
| Main functions | Real time 1/3 octave frequency spectrum analysis and integration measurement of vibration. |
| integrator | Parallel (simultaneous) first-order and second-order integration. Under the spectrum analysis interface, spectrum synthesis is performed; Implemented by digital filtering in the total value analysis interface |
| Detection characteristics | Parallel (simultaneous) effective value, peak value, peak to peak value |
| Effective Value Characteristics | Fast and slow exponential averaging, 1-second linear averaging. Fast gear time constant 1 second, slow gear time constant 8 seconds |
| Filter type | Parallel (real-time) 1/3 octave band, G=2, Digital filter. |
| Filter center frequency | 10Hz、12.5Hz、16Hz、20Hz、25Hz、31.5Hz、40Hz、50Hz、63Hz、80Hz、100Hz、125Hz、160Hz、200Hz、250Hz、315Hz、400Hz、500Hz、630Hz、800Hz、1kHz、1.25kHz、1.6kHz、2kHz、2.5kHz、3.15kHz、4kHz、5kHz、6.3kHz、8kHz、10kHz、12.5kHz、16kHz、20kHz |
| meet the standard | IEC 61260:1995 Class1 |
| Main menu | 1/3 OCT analysis, total value analysis, parameter settings, data management, calibration five submenus |
| Main measurement indicators | Main measurement indicators: 1-second linear average of frequency band (a)fmeq,1s、vfmeq,1s、sfmeq,1s)Linear average of frequency band (a)fmeq,T、vfmeq,T、sfmeq,T)The effective values, peak values, and peak to peak values of acceleration, velocity, and displacement, as well as the measurement experience time (Tm) |
| integration time | From 1 second to 24 hours, it can be set in stages or set arbitrarily |
data store |
It can store 1-second linear average, linear average integral, and integral measurement results of total value analysis for 1/3 octave band analysis, with an additional 12288 sets. The measurement results can also be stored on a USB flash drive |
Measurement range (15.92Hz as reference frequency, equipped with 2pC/m/s)2The accelerometer |
Acceleration: 0.05m/s2~5000m/s2 Speed: 0.5mm/s~50000mm/s Displacement: 0.005mm~500mm |
| frequency range |
Acceleration (low frequency range): 2 Hz~20 kHz Acceleration (high frequency range): 10 Hz~20 kHz Speed (low frequency range): 2 Hz~1.5 kHz Speed (high frequency range): 10 Hz~1.5 kHz Displacement (low frequency band): 2 Hz~200 Hz Displacement (high frequency band): 10 Hz~200 Hz
|
| Basic measurement error | 5% (15.92 Hz as reference frequency) |
Performance indicators of vibration FFT analysis module:
| Main functions | Real time FFT spectrum analysis and integral measurement of vibration |
| integrator | Implementing parallel (simultaneous) acceleration, velocity, and displacement through digital filtering in the total value analysis interface |
| Detection characteristics | Parallel (simultaneous) effective value, peak value, peak to peak value |
| Effective Value Characteristics | Fast and slow exponential averaging, 1-second linear averaging. Fast gear time constant 1 second, slow gear time constant 8 seconds |
| FFT analysis line count | 512 lines, showing 200 spectral lines |
| sampling frequency | 48kHz、24kHz、12kHz、6kHz、3kHz、1.5kHz |
| Analyze the upper limit of frequency | 18.75kHz、9375Hz、4687Hz、2344Hz、1172Hz、586Hz |
| Each line bandwidth | 93.75Hz、46.875Hz、23.438Hz、11.74Hz、5.8594Hz、2.9297Hz |
| overlap rate | 0%, 50%, 75%, 87.5%, 93.75%, 97% |
FFT result averaging method |
Exponential and linear. The exponential time constant is divided into two levels, F and S, with the F level having a time constant of 125ms and the S level having a time constant of 1000ms |
Linear range |
Above 90dB |
data store |
Fast time weighted instantaneous value, slow time weighted instantaneous value, 1-second integral value, and integral value that can be stored for FFT analysis; The instantaneous values and integral measurement results of the total value analysis have an additional 12288 sets, and the measurement results can also be saved to a USB flash drive |
Measurement range (15.92Hz as reference frequency, equipped with 2pC/m/s)2The accelerometer |
Acceleration: 0.05m/s2~5000m/s2 Speed: 0.5mm/s~50000mm/s Displacement: 0.005mm~500mm |
| frequency range |
Acceleration (low frequency range): 2 Hz~20 kHz Acceleration (high frequency range): 10 Hz~20 kHz Speed (low frequency range): 2 Hz~1.5 kHz Speed (high frequency range): 10 Hz~1.5 kHz Displacement (low frequency band): 2 Hz~200 Hz Displacement (high frequency band): 10 Hz~200 Hz
|
| Basic measurement error | 5% (15.92 Hz as reference frequency) |