E-mail
2524300166@qq.com
-
Phone
18015580277
-
Address
No. 55 Dongfu Road, Suzhou Industrial Park
Suzhou Yucheng Instrument Co., Ltd
2524300166@qq.com
18015580277
No. 55 Dongfu Road, Suzhou Industrial Park
AWA6258 three-axis vibration measurement analyzerIt is a multi-channel handheld analyzer that uses digital signal processing technology and can simultaneously measure three-axis vibration. It has multiple frequency weights for evaluating vibrations. It can perform whole-body vibration measurement, hand transmitted vibration measurement, environmental vibration measurement, and also perform 1/3 OCT spectrum analysis on vibration.
AWA6258 three-axis vibration measurement analyzertechnical parameters
| execution standard |
GB/T 23716-2009 Instruments for measuring human response to vibration (ISO 8041:2005, IDT) GB/T 3241-2010 Acoustics - Octave and Fractional Octave Filters (IEC 61260:1995, MOD) |
|
| Applicable standard |
GB/T 10071-1988 Measurement Method for Environmental Vibration in Urban Areas; GB/T 13441.1-2007 Mechanical Vibration and Shock - Evaluation of Human Exposure to Whole Body Vibration - Part 1: General Requirements (ISO 2631-1:1997, IDT); GB/T 13441.2-2008 Mechanical Vibration and Shock - Evaluation of Human Exposure to Whole Body Vibration - Part 2: Vibration inside Buildings (1 Hz~80 Hz) (ISO 2631-2:2003, IDT); GB/T 14790.1-2009 Mechanical Vibration - Measurement and Evaluation of Human Exposure to Hand transmitted Vibration - Part 1: General Requirements (ISO 5349-1:2001, IDT); GB/T 14790.2-2014 Mechanical Vibration - Measurement and Evaluation of Human Exposure to Hand Transmitted Vibration - Part 1: Practical Guidelines for Workplace Measurements (ISO 5349-1:2001, IDT); GB/T 50355-2005 Standard for Indoor Vibration Limits and Measurement Methods of Residential Buildings; GB/T 50452-2008 Technical Specification for Industrial Vibration Prevention of Ancient Buildings; JGJ/T 170-2009 Standard for Limits and Measurement Methods of Building Vibration and Secondary Radiation Noise Caused by Urban Rail Transit; Other relevant standards, etc; |
|
|
Frequency weighting and its range (with 10-6 m/s2For reference) |
VLx-y (whole body level) 70-175 VLz (whole body vertical) 80-185 Wb (z-axis, seat surface) 81-185 Wc (x-axis, seat backrest) 78-183 Wd (x, y axis, seat surface) 73-184 We (rx, ry, rz axis, seat surface) 70-168 Wj (vertical, lying down (head)) 88-185 Wk (z-axis, seat surface) 80-185 Wm (building) 70-180 Wh (arm) 70-185 |
|
| frequency range | Whole body vibration measurement |
VLx-y/VLz : 1.25 Hz~63 Hz(±1 dB) 1 Hz~80 Hz(±2 dB) Wb/Wc/Wd/We/Wj/Wk: 0.63 Hz~63 Hz(±1 dB) 0.315 Hz~125 Hz(±2 dB) 0.315Hz~250Hz(+2dB~-∞) Wm: 1.25Hz~63Hz(±1dB) 0.63Hz~125Hz(±2 dB) 0.315Hz~250Hz(+2dB~-∞) |
| Hand transmitted vibration measurement |
Wh : 10 Hz~800 Hz(±1 dB) 5 Hz~1600 Hz(±2 dB) VBLe : 12.5 Hz~630 Hz(±1 dB) 8 Hz~1000 Hz(±2 dB) |
|
| Low frequency 1/3 OCT analysis | 0.315 Hz~250 Hz(±1 dB) | |
| Vibration 1/3 OCT analysis |
20 Hz~2000 Hz(±5%) 2.5 Hz~2000 Hz(±12%) |
|
| Online measurement of blasting vibration | 4 Hz~180 Hz(±1 dB) |
|
| Time averaged constant | 1s、8s | |
| Time averaged method | Exponential average, linear average | |
| Main measurement indicators |
Whole body vibration measurement: Max, Min, Leq, T, 5 Ln (n can be set between 1 and 99) SD、Peak、VDV、VLxyz、VLcdd、VLddk Hand transmitted vibration measurement: Max, Min, Leq, T, Leq, 4h, Leq, 8h Low frequency 1/3 OCT analysis: Max, Min, Leq, T, 5 Ln (n can be set between 1 and 99), 30 center frequency points AP、SD、 5 synthetic frequency weights (wz, wx, wm, wk, wu) Vibration 1/3 OCT analysis: Max, Min, Leq, T, 30 center frequency points acc、vel、disp Online measurement of blasting vibration: peak velocity and peak frequency in three directions |
|
| sampling frequency | 750 Hz or 12 kHz | |
| Statistical sampling interval | 0.1s | |
| storage capacity | Built in 32M bit Flash RAM, with an additional 1024 sets of data or 81920s to record results |
|
| output interface | DC, AC RS232、USB、 Bluetooth |
|
| working power supply | 6 LR 6 alkaline or rechargeable batteries, capable of continuous use for more than 12 hours; An external DC power supply of 4 V to 6 V can also be used | |
| working environment |
Working temperature: -10 ℃~50 ℃ Storage temperature: -20 ℃~70 ℃ Relative humidity: 25% RH to 90% RH |
|