vortex flow meter

NegotiableUpdate on 01/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Application characteristics: LUDC series vortex flow transmitter, mainly used for flow measurement of industrial pipeline fluid media, such as gas, liquid, steam and other media

Product Details

Usage characteristics

The LUDC series vortex flow transmitter is mainly used for measuring the flow of fluid media in industrial pipelines, such as gases, liquids, steam, and other media.Its characteristics are small pressure loss, large measurement range, high accuracy, and almost no dependence on fluid density, pressure, temperature, viscosity and other parameters when measuring volumetric flow rate under working conditionsThe impact. No movable mechanical parts, therefore high reliability and maintenance requiredSmall. The instrument constant can remain stable for a long time. The plug-in instrument is installed at the insertion port of the pipeline,Ball valves can be continuously loaded and unloaded.To facilitate regular cleaning and maintenance when operating in dirty media. This instrument adopts a piezoelectric stress sensor with high reliability and can operate within a temperature range of -20 ℃ to+300 ℃. There are simulations availableStandard signals, as well as digital pulse signal outputs, are easily compatible with digital systems such as computers, making them a relatively advanced choiceIdeal flow meter.

working principle

When a cylindrical resistance body is vertically inserted into a fluid, vortices are alternately generated on both sides, and as the fluid moves downstream,

The formation of a vortex column is called a Karman vortex street, as shown in Figure 1. The resistance body that generates vortex streets is called a vortex generator. Experimental results have shown that the frequency of vortices is directly proportional to the flow velocity,

It can be expressed as follows:

Experimental evidence shows that when the distance h between two columns of vortices and the distance L between two vortices in the same column satisfy the formula h/L=0.281, asymmetric vortices

The vortex column can maintain a stable state. When the Reynolds number Re of the fluid is in the range of 5000-150000, Sr remains basically unchanged, so when vortices occur

When the cylinder width d and Strouhal number Sr are constant, the frequency f of the vortex generator is proportional to the average flow velocity of the fluid, that is, proportional to the flow Q and proportional to

Pressure, temperature, density and other parameters are irrelevant.

When vortices are generated on both sides of the cylinder, the sensor is subjected to alternating lift perpendicular to the flow direction, generating a signal. The frequency of the change in lift is

Vortex frequency, the sensor amplifies and shapes the signal to obtain a pulse signal that is linearly proportional to the flow velocity, which is directly output or converted into

The relationship between the flow rate Q and frequency f for the 4-20mA standard signal output is as follows:

Technical parameters of LUDC series vortex flowmeter

instrument model

LUDC

measuring medium

Gas, liquid, steam

Caliber specifications

Flange card mounted caliber specification

15, (20),25,32,40,50,65,80,100,125,150

Flange connected caliber specification

125, 150, 200, 250 (350)

Insertion caliber specification

200-2000

Flow measurement range

Normal measurement flow rate range

Reynolds number 1.5 × 104-4 × 106; Gas 5-50m/s; Liquid 0.5-7m/s.

Normal measurement flow range

The measurement range of liquid and gas flow rates is shown in Table 2; The steam flow range is shown in Table 3; The range of plug-in flow is shown in Table 4

measurement accuracy

Flange card type and flange type are liquid level 1 and gas level 1.5

The accuracy of the plug-in measuring head is level 1, and the accuracy of inserting it into industrial pipelines is ≥ level 2.5

Temperature of the measured medium

Normal temperature -25 ℃ -80 ℃ High temperature -25 ℃ -250 ℃ or -25 ℃ -300 ℃

work pressure

1.6MPa; 2.5MPa; 4.0MPa (can be produced according to ordering requirements)

output signal

(Signal line interface H20 × 1.5 internal thread)

Pulse voltage output signal

High level 8-10V, low level 0.7-1.3V (explosion-proof model: high level 4-5V, low level 0.7-1.3V)

The pulse duty cycle is about 50%, and the transmission distance is 100 meters.

Standard current output signal

DC4-20Ma allows external load resistance less than 600 Ω (power supply DC24V), with a transmission distance of 3000 meters.

Instrument usage environment

Temperature: -25 ℃ -+55 ℃ Humidity: 5-90% RH50 ℃

material

The body is made of stainless steel 304, and the converter housing is made of aluminum alloy.

power supply

DC12V±10% DC24V±10%; Lithium battery 3.6V

Explosion-proof rating

Intrinsically safe explosion-proof Exia Ⅱ CT1-T5, explosion-proof Exd Ⅱ BT4

Protection level

IP65

Requirements for front and rear straight pipe sections

Refer to Tables 7 and 8

Flow range of liquid and working gas

path

mm

15

20

25

32

40

50

65

80

100

125

150

200

250

300

liquid

m3/h

0.3-3

0.5-5

1.2-12

1.5-15

2.2-22

4-40

6-60

9-90

14-140

22-220

35-350

65-650

120-1200

180-1800

gas

m3/h

5-30

5.5-56

10.2-80

15-150

22-220

35-350

60-600

90-900

140-1400

220-2200

300-3000

550-5500

1100-11000

1500-15000

Saturated steam flow range

Table 3

Path diameter 25mm 32mm 40mm 50mm 65mm 80mm 100mm 125mm 150mm 200mm

temperature

Density kg/m ³
pressure minimum minimum minimum minimum minimum minimum minimum minimum minimum minimum
0.1 20 101 22.5 150 36 229 59 358 93 600 129 917 220 1.43 348 2.25 479 3.22 840 5.73 120.1 1.126
0.2 21 136 29.5 210 47 333 77 520 124 880 168 1.33 288 2.08 463 3.30 628 4.68 1.10 8.34 133.3 1.638
0.3 24 151 36 280 56 436 92 680 152 1.15 201 1.74 345 2.78 567 4.30 750 6.13 1.32 11.0 143.2 2.140
0.4 27 186 42 340 65 536 105 836 171 1.40 231 2.14 396 3.39 640 5.24 862 7.54 1.51 13.6 151.4 2.635
0.5 30 248 46 410 72 636 118 994 188 1.69 259 2.55 444 3.98 691 6.23 966 8.95 1.70 15.9 158.3 3.127
0.6 34 256 50 470 80 733 130 1.15 206 1.95 285 2.94 489 4.66 766 7.20 1.07 10.3 1.87 18.6 164.4 3.615
0.7 37 325 54 530 87 833 142 1.30 225 2.20 310 3.34 531 5.22 832 8.15 1.16 11.7 2.03 20.9 169.8 4.099
0.8 39 325 58 600 93 931 152 1.45 243 2.47 334 3.73 572 5.91 888 9.10 1.25 13.1 2.19 23.6 174.7 4.581
0.9 42 394 62 650 100 1.03 163 1.61 253 2.73 357 4.12 612 6.44 936 10.0 1.34 14.5 2.34 25.8 179.2 5.064
1.0 45 441 66 720 106 1.13 173 1.76 272 3.00 379 4.51 650 7.16 1.00 11.0 1.42 15.8 2.49 28.6 183.3 5.553
1.1 47 479 70 780 112 1.23 183 1.92 289 3.26 401 4.91 687 7.67 1.07 12.0 1.50 17.3 2.63 30.7 187.2 6.033
1.2 50 463 73 850 118 1.32 193 2.05 306 3.50 422 5.29 723 8.40 1.12 13.0 1.58 18.5 2.76 33.6 190.8 6.509
1.3 52 555 77 910 123 1.42 202 2.22 314 3.77 422 5.68 757 8.88 1.17 13.9 1.65 20.0 2.89 35.5 194.2 6.980
1.4 54 593 79 970 129 1.51 211 2.37 328 4.00 461 6.07 792 9.49 1.22 14.8 1.73 21.3 3.02 37.6 197.5 7.456
1.5 57 630 82 1.00 135 1.60 219 2.52 341 4.30 481 6.47 825 10.3 1.26 15.8 1.80 22.6 3.15 41.4 200.5 7.934
1.6 59 669 86 1.10 140 1.71 229 2.68 353 4.55 501 6.86 858 10.7 1.31 16.8 1.87 24.1 3.28 42.9 203.5 8.419
1.7 61 707 89 1.15 146 1.81 237 2.83 365 4.80 519 7.24 890 11.3 1.36 17.7 1.94 25.9 3.40 45.3 206.2 8.897
1.8 63 746 93 1.22 151 1.91 246 2.98 385 5.07 538 7.64 922 11.9 1.41 18.7 2.01 26.9 3.53 47.8 208.9 9.388
1.9 66 784 96 1.28 155 2.01 254 3.14 395 5.33 556 8.03 954 12.6 1.46 19.6 2.08 28.3 3.65 50.0 211.5 9.868
2.0 68 822 98 1.35 161 2.10 262 3.27 404 5.60 574 8.43 985 13.2 1.50 20.6 2.15 29.6 3.76 53.5 213.9 10.35
3.0 87 1.21 128 1.98 207 3.10 338 4.84 532 8.21 743 12.4 1.27 19.3 1.95 30.3 2.78 43.5 4.86 77.4 234.6 15.21
4.0 106 1.61 158 2.60 251 4.11 409 6.43 647 11.0 898 16.5 1.53 25.7 2.40 40.2 2.35 57.8 5.87 102.8 250.7 20.21
4.3 111 1.73 161 2.80 264 4.43 429 6.91 666 11.6 942 17.7 1.61 27.7 2.47 43.0 3.52 62.2 6.17 110.6 254.9 21.74

Note: 1. The units of gray shaded data in the table above are t/h, while the units of other data are kg/h. The unit of pressure is MPa.
2. If the diameter is greater than 200mm, the range of steam flow can be measured by multiplying the gas flow rate of the corresponding diameter by the steam density at the corresponding pressure and temperature.

Flow Range Table 4 of Liquid (Gas, Steam) Insertion Vortex Flow Meter

Diameter (mm)
DN

Liquid (m ³/h)

Gas (m ³/h)

Diameter (mm)
DN

Liquid (m ³/h)

Gas (m ³/h)

minimum

minimum

minimum

minimum

200

55

570

560

4530

900

1145

11450

11450

91605

250

88

885

880

7070

1000

1410

14140

14135

113095

300

125

1275

1270

10180

1100

1710

17110

17100

136840

350

170

1735

1730

13860

1200

2035

20360

20230

162850

400

225

2265

2260

18100

1300

2385

23895

23890

191125

450

286

2870

2860

22905

1400

2770

27710

27705

221660

500

350

3540

3530

28275

1500

3170

31800

31700

254455

600

505

5090

5085

40715

1600

3610

36200

36105

289510

700

690

6930

6925

55420

1800

4580

45850

45750

366410

800

900

9050

9045

72380

2000

5650

56550

56545

452365

Structure and dimensions

This series of vortex street transmitters has three connection methods and external dimensions
Flange card installation type
Mainly used for full tube vortex street meters with diameters ranging from 15 to 100. Refer to Figure 3 and Table 5
Flange connection type
Mainly used for full tube vortex street meters with diameters ranging from 125 to 350. Refer to Figure 3 and Table 5
plug-in
Mainly used for large-diameter pipelines with diameters ranging from 200 to 2000. Refer to Figure 4 on the right
Ball valves are mainly used for continuous flow loading and unloading, and are convenient for regular operation in dirty media
Cleaning and maintenance. Provided by users as needed)

Dimensions of flange mounted and flange connected vortex street transmitters

Surface type

Nominal Diameter

mm

pressure rating

MPa

L

mm

G

D

mm

D1

mm

N-d2

d

mm

b

mm

weight

Kg

room temperature

high temperature

Flange card installation type

15(20)

4.0

66

280

500

65

15

7.5

25

4.0

66

280

500

65

25

7

32

4.0

66

285

505

72

32

10

40

4.0

70

290

510

80

40

11

50

4.0

85

295

515

90

50

12.5

65

2.5

98

310

530

105

65

17

80

2.5

110

320

540

120

80

20

100

2.5

110

330

550

150

100

27

125

1.6

115

340

560

164

125

30

150

1.6

130

350

570

188

150

35

Flange connection type

125

1.6

250

323

545

245

210

8-φ18

125

26

22

150

1.6

300

335

555

280

240

8-φ23

150

28

24

200

1.6

320

370

590

335

295

12-φ23

200

30

31

250

1.6

320

400

620

405

355

12-φ25

250

32

40

300

1.6

320

420

640

460

410

12-φ25

300

32

48

Special pressure levels require customization

Model selection and description

model Basic code Explanation
LUDC Basic model of stress type vortex street transmitter
connection method -1 flanged
-2 Flange card installation type
-3 plug-in
Tested medium 2 liquid
3 gas
4 saturated steam
4G superheated steam
5 hot water
Path marking -xxx Please refer to the nominal diameter table for details
output signal -0 No signal output
-3 Three line to pulse
-4 2-line system 4-20mA
Header indication
N No indicator header
B Double row LCD display intelligent meter head (instantaneous, accumulated flow)
Connect power supply
x 12V DC (only equipped with three wire pulse output)
y 24V DC
z Battery (only equipped with intelligent digital display meter B)
Table body material
-C OCr18Ni12Mo2Ti (316)
-D 1Cr18Ni9Ti (304)
pressure 1 1.6MPa (DN65-200)
2 2.5MPa (DN15-50)
3 4.0MPa (DN15-50)
explosion-proof performance
-N none
-Bi Intrinsic safety explosion-proof type
-Bd flameproof type

Diameter (mm)

15

20

25

32

40

50

65

80

100

125

150

200

250

300

350

400

450

500

logo

001

0012

002

003

004

005

006

008

010

012

015

020

025

030

035

040

045

050

path
(mm)

600

700

800

900

1000

1100

1200

1300

1400

1500

1600

……

2000

logo

060

070

080

090

100

110

120

130

140

150

160

……

200