Overview

The LSQ ultrasonic open channel flowmeter is mainly used for measuring flow in dry rivers with free flow conditions, irrigation channels, factories, urban sewage drainage ditches, and non full pipe pipelines

Product Details

Instrument usage


The LSQ ultrasonic open channel flowmeter is mainly used for measuring the flow in dry rivers with free flow conditions, irrigation channels, factories, urban sewage drainage ditches, and non full pipe pipelines. When the instrument is working, the sensor does not come into contact with the measured fluid, avoiding contamination and corrosion by sewage in the channel. Used for measuring sewage flow, it has higher reliability compared to other forms of instruments.
This flowmeter adopts ultrasonic measurement, microcomputer processing, and large screen digital display, and can be installed and automatically measured in harsh environments. The adoption of oscilloscope technology enables instruments to have high reliability and strong anti-interference ability. Easy installation and maintenance, easy to read. Widely used for measuring sewage discharge from industries such as dry petroleum, chemical, textile, and pharmaceutical, it is one of the main instruments for urban pollution prevention and environmental protection departments to monitor sewage discharge from enterprises and institutions. It is also an instrument for measuring agricultural irrigation water discharge.

Main Features
1、 Large screen LCD backlight display with large information capacity, capable of displaying instantaneous flow rate, cumulative flow rate, liquid level, time, and instantaneous flow bar on the same screen.
2、 This instrument has data storage functions for hourly, daily, monthly, annual flow and power outage information. The stored data is not lost in case of power failure, and can be viewed through the buttons on the instrument panel. It has automatic temperature compensation and environmental temperature display functions.
3、 The oscilloscope technology, also known as signal environment display, can clearly display the waveforms of the emitted waves, reflected waves, and interference waves of ultrasonic waves. The application of oscilloscope technology makes this process clear and visible, enhancing the usability of the instrument.
4、 When applied to narrow channels, the interference echo generated by the channel sidewall has no effect on this instrument. It is currently an instrument that uses wave difference level and oscilloscope technology to achieve suppression and anti-interference ability against the interference echo.

Main technical indicators and parameters

flow range

0-10 m3/s (determined by the type and specifications of the measuring weir used)

Liquid resolution

1mm

cumulative flow

A 12 digit decimal number that automatically returns to zero when fully accumulated

Working environment temperature

-20℃~55℃

traffic accuracy

1%

Instrument protection level

IP65

measuring range

3 meters

power supply

AC power supply 220V ± 10% 6W

Ranging accuracy

0.25%

Overall dimensions

Length x Width x Height: 270 x 192 x 80mm

performance parameters

project

performance parameters

host

Backlit LCD can simultaneously display data such as instantaneous flow and cumulative flow, instantaneous heat and cumulative heat, flow rate, time, etc

signal output

Current output: 4~20mA or 0~20mA, impedance 0~1K, accuracy 0.1%, etc

CCT output: frequency signal of positive, negative, net current or heat accumulation pulse signal or instantaneous flow rate (optional between 0~9999Hz)

Relay: capable of outputting nearly 20 types of source signals

signal input

Sound alarm: The buzzer can emit an alarm sound according to the settings (such as too high or too low current)

It can input five current signals (such as temperature, pressure, liquid level, etc.) to achieve heat measurement or dual-use of one machine

Data interface: The factory configuration is RS-232 mode, and after selecting an RS-232/RS-485 converter, it can be changed to RS-485 mode

Pipeline condition

pipe material

Steel, stainless steel, cast iron, cement pipe, copper PVC、 All dense pipelines such as aluminum and fiberglass are allowed to have lining

inner diameter of pipe

15mm~6000mm

straight pipe section

The installation point of the sensor meets the following requirements: upstream 10D, downstream 5D, and 30D from the pump outlet (D refers to the pipe diameter)

measuring medium

category

Water, seawater, industrial wastewater, acidic and alkaline liquids, alcohol, beer, various oils and other single and uniform liquids that can transmit ultrasonic waves

temperature

0℃~110℃

flow velocity

0~±30m/s

turbidity

≤ 10000ppm with low bubble content

flow direction

Positive and negative bidirectional measurement, and can measure net flow or heat

working environment

temperature

Host: -30 ℃~-18 ℃ Flow sensor: -40 ℃~110 ℃ Temperature sensor: selected according to customer needs

humidity

Host: 85% RH flow sensor: capable of working in water with a depth of ≤ 3m

power supply

Data interface: The factory configuration is RS-232 mode, and after selecting an RS-232/RS-485 converter, it can be changed to RS-485 mode

power consumption

2W (with the lowest power consumption among similar models in China)

weight

200F:2.5Kg 200BF:7.0Kg 200A:2.0kg 100F:2.5Kg