turbine flow meter

NegotiableUpdate on 01/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Overview: The LWY series turbine flowmeter has the characteristics of simple structure, lightweight, high accuracy, good repeatability, sensitive response, and easy installation, maintenance, and use

Product Details

Overview


The LWY series turbine flowmeter has the characteristics of simple structure, lightweight, high accuracy, good repeatability, sensitive response, and easy installation, maintenance, and use.
Typical applications include water, diesel, methanol, and other non impurity and non corrosive liquids. When paired with display instruments with special functions, it can also perform quantitative control and over limit alarm, making it an ideal instrument for flow measurement and energy conservation.


feature


1. The sensor is a hard alloy bearing thrust type, which not only ensures accuracy and improves wear resistance, but also has the characteristics of simple structure, firmness, and easy disassembly and assembly
2. Multiple transmitter modes: three wire pulse output; 2-wire system with 4~20mA current output; On site display and output 4~20mA; Battery powered, suitable for different usage scenarios
3. Intelligent processing: multi-point non-linear correction of instrument coefficients to ensure high precision across the entire range
4. Instrument coefficient and cumulative flow value are maintained in case of power failure for ten years without loss


working principle
The fluid flows through the sensor housing, and the blades of the dry impeller have a certain angle with the flow direction. The impulse of the fluid causes the blades to have a rotational torque. After overcoming the friction torque and fluid resistance, the blades rotate. After the torque is balanced, the speed is stable. Under certain conditions, the speed is proportional to the flow rate. Due to the magnetic conductivity of the blades, they are in the magnetic field of the signal detector (composed of magnetic steel and coils). The rotating blades cut the magnetic field lines and periodically change the magnetic flux of the coil, causing electrical pulse signals to be induced at both ends of the coil. This signal is amplified and shaped by an amplifier to form a continuous rectangular pulse wave with a certain amplitude, which can be transmitted to the display instrument remotely to display the instantaneous flow rate or total amount of the fluid.
Within a certain flow range, the pulse frequency f is proportional to the fluid flowing through the sensor (instantaneous flow rate Q), and the flow calculation formula is:

Basic performance parameters

measuring medium

Liquid (not corrosive to 304 or 316 stainless steel, 2Cr13 steel or nickel, and steel jade Al2O3)

Diameter mm

threaded connection

4. 6, 10, 15, 20, 25, 32, 40

flange connection

(25)、(32)、(40)、50、65、80、100、125、150、200

(DN25-40 is usually a threaded connection, flange connection requires special ordering)

accuracy class

Level 1, Level 0.5 (up to Level 0.2 for specific traffic segments)

repetitiveness

± 0.2% of the indicated value

medium temperature

-20℃~+120℃

Applicable Environment

Temperature: -20 ℃~+55 ℃, humidity: 5-95%

Protection level

IP67

Explosion-proof rating

ExmIICT6 ExdIIBT6

power supply

12VDC 24VDC or battery powered (3.2V 10AH)

output signal

pulse output

Voltage amplitude: High level ≥ 8V, low level ≤ 0.8V

Transmission distance ≤ 1000 meters

standard current

4-20mA DC

Straight pipe section requirements

Flow meter upstream ≥ 20DN downstream ≥ 5DV

Measurement range and nominal pressure

Diameter DN mm

Normal measurement range m ³/h

Expand flow range m ³/h

Conventional nominal pressure MPa

High pressure type pressure resistance MPa

4

0.04-0.25

0.04-0.4

6.3

25

6

0.1-0.6

0.06-0.6

6.3

25

10

0.2-1.2

0.15-1.5

6.3

25

15

0.6-6

0.4-8

6.3

25

20

0.8-8

0.45-9

6.3

25

25

1-10

0.5-10

6.3 (flange 4.0)

25

32

1.5-15

0.75-15

6.3 (flange 4.0)

25

40

2-20

1-20

6.3 (flange 4.0)

25

50

4-40

2-40

2.5

25

65

7-70

4-70

2.5

25

80

10-100

5-100

2.5

25

100

20-200

10-200

2.5

25

125

25-250

13-250

2.5

25

150

30-300

15-300

1.6

16

200

80-800

40-800

1.6

16

Outline structure and dimensions of conventional turbine flowmeter sensors

① LWY-4~10 sensor structure
Installation dimension diagram
② LWY-15~40 sensor structure
Installation dimension diagram
③ LWY-15~200 Sensor Structure
Installation dimension diagram

Size Chart

Nominal diameter mm

L(mm)

G

D(mm)

d(mm)

H (number of holes)

4

225

G1/2

 

 

 

6

225

G1/2

10

345

G1/2

15

75

G1

φ65

φ14

4

20

80

G1

φ75

φ14

4

25

100

G5/4

φ85

φ14

4

32

140

G2

φ100

φ14

4

40

140

G2

φ110

φ18

4

50

150

 

φ125

φ18

4

65

170

 

φ145

φ18

4

80

200

 

φ160

φ18

8

100

220

 

φ180

φ18

8

125

250

 

φ210

φ25

8

150

300

 

φ250

φ25

8

200

360

 

φ295

φ23

12

Selection instructions:

Model Number

Instructions

LWY

public

call, name, say, weigh

through

path

4

4mm, The flow range of a regular turbine is 0.04~0.25m3/h, while that of a wide range turbine is 0.04~0.4m3/h

6

6mm, The flow range of a regular turbine is 0.1~0.6m3/h, while that of a wide range turbine is 0.06~0.6m3/h

10

10mm, The flow rate range of ordinary turbines is 0.2~1.2m3/h, while that of wide range turbines is 0.15~1.5m3/h

15

15mm, The flow range of a regular turbine is 0.6~6m3/h, while that of a wide range turbine is 0.4~8m3/h

20

20mm, The flow range of a regular turbine is 0.8~8m3/h, while that of a wide range turbine is 0.45~9m3/h

25

25mm, The flow rate range of ordinary turbines is 1-10m3/h, while that of wide range turbines is 0.5-10m3/h

32

32mm, The flow range of a regular turbine is 1.5~15m3/h, while that of a wide range turbine is 0.75~15m3/h

40

40mm, The flow rate range of ordinary turbines is 2-20m3/h, while that of wide range turbines is 1-20m3/h

50

50mm, The flow rate range of ordinary turbines is 4~40m3/h, while that of wide range turbines is 2~40m3/h

65

65mm, The flow range of a regular turbine is 7-70m3/h, while that of a wide range turbine is 4-70m3/h

80

80mm, The flow range of a regular turbine is 10-100m3/h, while that of a wide range turbine is 5-100m3/h

100

100mm, The flow range of a regular turbine is 20~200m3/h, while that of a wide range turbine is 10~200m3/h

125

125mm, The flow range of a regular turbine is 25~250m3/h, while that of a wide range turbine is 13~250m3/h

150

150mm, The flow range of a regular turbine is 30~300m3/h, while that of a wide range turbine is 15~300m3/h

200

200mm, The flow range of a regular turbine is 80~800m3/h, while that of a wide range turbine is 40~800m3/h

type

N

Basic type, 12~24VDC power supply, three wire pulse output

A

4-20mA two-wire current output, remote transmission type

B

Battery powered on-site display type, no current output

C

On site display with 4-20mA two-wire current output type

accuracy class

05

Accuracy level 0.5

10

Grade 1 accuracy

Turbine type

W

Wide range turbine (accuracy can only be selected as 1.0 level)

S

Standard turbine

body material

S

304 stainless steel

L

316 stainless steel

explosion-proof

N

No explosion-proof

E

Explosion proof type (Exd Ⅱ BT6)

pressure rating

N

Conventional (refer to the measurement range and nominal pressure on page 2)

H

High pressure (refer to the measurement range and nominal pressure on page 2)

Note: DN4~10 are all threaded connections and come standard with front and rear straight pipe sections and filters;
② DN15~40 is also commonly connected by threads, but flange connection can also be selected for DN15~40. When selecting, it is necessary to add oil after the diameter
(FL) represents flange connection;
③ DN50~200 are all flange connections.

Overview


The LWQ series gas turbine flowmeter is a new generation of high-precision and high reliability gas precision measuring instrument that integrates temperature, pressure, flow sensors, and intelligent flow integrators. It has been independently developed by drawing on domestic and foreign flow instrument technology and optimizing design, and integrating theories of gas mechanics, fluid mechanics, electromagnetics, etc. It has excellent low-pressure and high-pressure metering performance, multiple signal output modes, and low sensitivity to fluid disturbances, and is widely used for metering gases such as natural gas, coal to gas, liquefied gas, and light hydrocarbon gas.

Product Features


Adopting a new type of sensor, it has low starting flow rate, small pressure loss, good anti vibration and anti pulsating flow performance, is not easy to corrode, has good reliability, and has a long service life.
Adopting a new type of microprocessor and high-performance integrated chips, it has high computational accuracy, powerful overall functions, and high performance.
The micro power consumption used has low overall power consumption. It can operate on both internal battery power for a long time and external power supply.
According to the flow frequency signal, the instrument coefficient can be automatically linearly corrected in eight segments, which can improve the calculation accuracy of the instrument according to user needs.
Adopting EEPROM data storage technology, it has the function of storing and querying historical data, and three historical data recording methods are available for users to choose from.
The flowmeter head can rotate 180 degrees, making installation and use simple and convenient.
High precision, generally up to ± 1.5% R and ± 1.0% R0.
Good repeatability, short-term repeatability can reach 0.05%~0.2%. It is precisely because of its good repeatability that flow meters are preferred for trade settlement

Basic Parameters

Instrument diameter (mm) and connection method

25, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300 are connected by flanges

25, 40, 50, can be connected with threads

accuracy class

±1.5%

Instrument material

Table body: 304 stainless steel or cast aluminum Converter: cast aluminum

Impeller: anti-corrosion ABS or high-quality aluminum alloy

Terms of Use

Medium temperature: -20 ℃~80 ℃, humidity: 5-95%

Environmental temperature: -30 ℃~60 ℃, atmospheric pressure: 80kpc-106kpc

working power supply

External power supply:+24VDC, suitable for 4-20mA output, pulse output, RS485, etc., with a total power consumption of less than 1W

Internal power supply: 1 set of 3.6V10AH lithium batteries, no signal output, average power consumption ≤ 1W, can be connected and used for more than 3 years.

Signal line connection

Internal thread M20 * 1.5 or other

Explosion-proof rating

Exia Ⅱ CT4 or Exd Ⅱ BT6

Protection level

IP65

size

Diameter mm

L

D

K

N

D

bolt specification

Conventional pressure resistance MPa

DN25

170

115

85

4

φ14

M12×50

4.0

DN40

200

150

110

4

φ18

M16×55

DN50

200

165

125

4

φ18

M16×60

DN65

240

185

145

4

φ18

M16×65

1.6

DN80

240

200

160

8

φ18

M16×70

DN100

300

220

180

8

φ18

M16×80

DN125

240

250

210

8

φ18

M16×80

DN150

450

285

240

8

φ22

M20×80

DN200

600

340

295

12

φ22

M20×90

DN250

500

403

355

12

φ26

M24×90

DN300

300

460

410

12

φ26

M24×100

measurement range

Nominal diameter (mm)

model

Range (m3/h)

Initial flow rate (m3/h)

pressure rating

Installation method

DN25

LWQ-25

2.5-25

1

1.6

Flange (thread)

DN40

LWQ-40

5-50

2.5

1.6

Flange (thread)

DN50

LWQ-50A

6-65

3.5

1.6

flange

LWQ-50B

10-100

DN65

LWQ-65

15-200

5

1.6

flange

DN80

LWQ-80A

13-250

5

1.6

flange

LWQ-80B

20-400

DN100

LWQ-100A

20-400

8

1.6

flange

LWQ-100B

35-650

DN125

LWQ-125

35-700

10

1.6

flange

DN150

LWQ-150A

35-700

10

1.6

flange

LWQ-150B

50-1000

DN200

LWQ-200A

80-1600

20

1.6

flange

LWQ-200B

130-2500

DN250

LWQ-250A

150-2500

30

1.6

flange

LWQ-250B

200-4000

DN300

LWQ-300

200-4000

40

1.6

flange

Selection and Explanation

Model Number

Instructions

LWQ

—□

—□

—□

ceremony

table

class

type

N

Basic type, pulse output, no display

A

Current output type, no display

B

On site display type (no signal output)

C

Display output type (on-site display+current output)

D

Temperature and pressure compensation type (on-site display+current output)

ceremony

table

path

25

25mm

40

40mm

50A/B

50mm

80A/B

80mm

100A/B

100mm

150A/B

150mm

200A/B

200mm

250A/B

250mm

300

300mm

sensor material

N

This material is aluminum alloy (pressure resistance: 1.0MPa), and the movement is made of anti-corrosion material

S

The body material is 304 stainless steel (high-pressure type), and the movement is made of anti-corrosion material