The pressure tapping ports of the boiler's air ducts, flues, furnaces, etc. are often blocked due to the presence of certain dust in the pipelines. After blockage, it is necessary to use a blower or other air source to blow them away, which increases a lot of maintenance workload. This device was developed under the strong demand to solve this headache problem through scientific analysis, careful design, and a pragmatic attitude of strictly controlling manufacturing quality. Through the experience of power plant use, it has been proven that it can achieve a permanent and unobstructed effect in the measurement of air pressure and differential pressure in the powder production and transportation (coal powder) system and furnace. Of course, it can also be used in the measurement of air pressure or differential pressure in cement, flour, metal powder, and other gases containing solid particles.
When you encounter blockages in the measurement of your high viscosity, low fluidity, and highly corrosive air powder mixture, please contact our factory. We can design and manufacture a satisfactory anti clogging sampler specifically for you.
Characteristics
Simple construction and low price.
No need for gas source, there is no problem of complex system or large installation workload.
No energy consumption, no maintenance required.
No additional measurement errors.
Installation requirements
The sampler must be installed vertically. Refer to Figure (1)
When it is difficult to install directly vertically on process pipelines or equipment, please extend the sampling pipe. The extension pipe should use a 11/2 "gas pipe, and the angle between the extension pipe and the horizontal plane should be greater than or equal to 60 °. The sampler itself must still be installed vertically, as shown in Figure (2)
When conditions permit, use a 11/2 "gas pipe to vertically extend the original outlet pipe by 300mm, and then use a seamless pipe with a diameter of 14 * 2 to lead it to the instrument.
Wind pressure measurement anti blocking sampler
Ordering Guide:
BRT-PFD-A □□-B□□-C□□
Anti blocking wind pressure sensor
A □□: Style type
01: Self cleaning and anti blocking sampling device
02: Vase type anti blocking sampling device
03: Furnace and flue pressure tube
04: Air blowing anti blocking device
05: Self cleaning and anti blocking sampling device (back-to-back)
06: Wind pressure sampling device (back-to-back)
07: Wind flow speed control tube (large and small tube type)
08: Wind flow speed control tube (large and small tube anti blocking type)
09: Wind flow speed control tube (S-shaped)
10: Wind speed uniform pipe (flute shaped pipe)
B □□: Material
01: Carbon steel*
02: Stainless steel
C □□: Installation method
01: Vertical*
02: Level