-
E-mail
ouyangchao@qh-ndt.com
-
Phone
15275259479
-
Address
No. 12, Lane 555 Tianzhu Road, Jiading District, Shanghai, 2004
Qianhu Testing (Shanghai) Co., Ltd
ouyangchao@qh-ndt.com
15275259479
No. 12, Lane 555 Tianzhu Road, Jiading District, Shanghai, 2004
OlympusUltrasonic flaw detectorPhased array probe 2.25L64-I4 5L64-I4
HydroFORM scanner
Advantages and Characteristics
●Localized water immersion technology.
●The coupling effect is optimized to detect rough surfaces.
●Large scale coverage.
●Avoiding wedge reflection.
●Convenient surface echo synchronization for monitoring corrosion on both outer and inner walls.
Typical Applications
I4probe
Corrosion imaging applications
●Manual or automatic corrosion detection can be performed on medium and large areas
Measurement of paired remaining wall thickness or internal corrosive materials
Dual Crystal Linear Array (DLA) Corrosion Probe
Advantages and Characteristics
●One send, one receive technology.
●Reduced surface echoes, thereby optimizing surface resolution.
●Detachable curved delay block.
●Built in irrigation.
●The adjustable ring components enhance stability and wear resistance.
●With twin crystalsUTCompared to technology,DLAHas higher detection rate and better imaging effect
Fruit, larger coverage area, and enhanced data point density.
Typical Applications
REX 1probe
●It can manually or automatically detect small and medium-sized areas to complete the task
Measurement of remaining wall thickness or internal corrosive materials.
ULT 1probe
●It is possible to manually detect small and medium-sized areas to achieve surface temperature measurement
Up to degree150 °C(300 °F)Remaining wall thickness or internal corrosion zone of the workpiece
Measurement of Domain Thickness
Introduction to phased array technology
The distinguishing feature of phased array ultrasonic testing from other technologies is that it can excite a single chip in a multi chip probe through computer control (amplitude and delay). By exciting multiple piezoelectric composite material chips through software, a focused ultrasonic beam can be generated by dynamically changing the parameters of the beam, such as angle, focal length, and focal size, during the emission process. To generate a sound beam through active interference in phase, multiple active chips of the probe need to be triggered with minimal time difference. Similarly, the echo reflected from the expected focal point will touch different chips of the probe with a computable time offset. Before summarizing the echo signals received by each chip, it is necessary to perform time offset calculations on these echo signals. The summary result is to generate an A-scan, which highlights the response signal from the desired focus and weakens the signal from other parts of the tested sample.
Use software to control the angle, focal length, and focal size of the sound beam
To generate an ultrasound beam, it is necessary to probe at very different times with minimal differences
Pulse excitation is performed on different chips of the head. By controlling the time delay between probe chips, sound beams with different angles, focal lengths, and focal sizes can be generated. The echo reflected from the expected focal point will touch different chips of the probe with a computable time offset. Before summarizing the echo signals received by each chip, it is necessary to perform time offset calculations on these echo signals. The result of signal aggregation is to generate an A-scan. This A-scan will highlight the response signal from the desired focus and weaken various echoes from other parts of the material.
Multi angle detection can be achieved using a single, compact polycrystalline probe controlled electronically
Conventional UT testing requires the use of multiple different probes. A single phased array (PA) probe can be configured according to application requirements to generate different angles and focal points in a sequential manner.
Complete high-speed scanning without moving parts
Although phased array technology processes many signals from multi chip probes, it is important to note that the resulting signal is a standard radio frequency (RF) signal (or A-scan) that is identical to any conventional system using a fixed angle probe. This signal, like any A-scan from a conventional UT system, can be evaluated, processed, filtered, and an image generated. The B-scan, C-scan, and D-scan created based on A-scan are also similar to the images generated by conventional systems. The difference between them is that phased array systems can use a single probe to complete multi angle detection. Multi channel transmission can also complete scanning without moving the probe: focusing the sound beam
Created from several chips of a long-range array probe containing many chips. Then the sound beam is moved (or multiplexed) to other chips to perform high-speed scanning of the workpiece along the scanning axis without moving the probe. This way, the probe can perform more than one scan at different detection angles. This principle can be applied to the detection of planar workpieces using linear phased array probes, as well as to the detection of pipes and bars using circular phased array probes.
OlympusUltrasonic flaw detectorPhased array probe 2.25L64-I4 5L64-I4



|
|||||||||