Transmission fogging instrument i

NegotiableUpdate on 02/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The BYK transmission fogger i (haze gard i) can objectively quantify data and digitize visual observations. One instrument can measure all important data related to transmission: total transmittance, transmission haze, and perspective clarity;
Product Details

BYKTransmission fogging instrument i

Objective standards for perspective observation

When light scatters through transparent products, it can produce a cloudy or blurry appearance.Transmission fogging instrument iThis objective measure can quantify people's feelings:

■ Full transmittance

■ Transmission fog shadow

■ Perspective clarity

The transmission fog imager i only needs one measurement to obtain all the parameters that control transparency.

universal

The standard measurement method for haze and total transmittance quality control in one instrument:

ASTM D 1003-C Light Source and A Light Source Non Compensation Method

ISO 13468-D65 light source compensation method

The transmission fog imager i can display all measurement results simultaneously - including all preset custom specifications.

Reliable and precise

The transmission fog imager i with * optical and LED technology brings * high-performance performance:

Reference beam, self diagnosis, and closed optical path

LED light source ensures stable measurement results for several years: bulb life is guaranteed for ten years!

Automatic long-term calibration - easy to operate and reliable

Ensure measurement repeatability and measurement accuracy between instruments.

Intelligent and Swift

The new touch screen design allows for easy and intuitive completion of any task.

Large color touch screen display

Icon based menu function selection

■ Measurement button

The foot switch can be operated without the need for manual operation

Open and flexible

The open measurement chamber allows you to freely analyze samples of any size:

Open design suitable for small or large samples

Quickly replace and locate the sample

Not affected by the surrounding ambient light

Multi functional sample holder suitable for measuring films and sheets

Taber Wear Test Stand and Test Tube for Liquid Measurement

Customized brackets for customers can be easily installed

Horizontal or vertical placement

Conveniently placing samples in any position brings * flexibility to your experiments.

Airborne analysis

For efficient work management, measurement data can be obtained throughDirectly analyze and save to the project file of the instrument:
■ Large memory capacity (can store 5000 readings)

■ It has complete statistical functions, including mean, minimum/maximum value, and standard deviation

■ Different tolerance values can be entered for different product requirements, and the qualified/unqualified analysis results can be displayed by color

Professional Connection

Data transmission can be carried out through various methods to support the daily work of your laboratory:

Directly transfer data to a personal computer through a USB port

■ Connect directly to your office network via LAN and conduct further analysis in your laboratory information management system (LIMS)

Save data to USB drive

Smart Lab Haze - Data Analysis Software:

The smart lab haze software is capable of performing any job you need, generating sample data tables for a single measurement series and trend analysis reports over a period of time - anything is possible.

Set user-defined product specifications in standard management and establish boundaries for product qualification/nonconformity assessment.

■ Measure your products online and display quality reports immediately: data tables with statistical results and line charts with colored indicators of qualified/unqualified

Manage your laboratory work in project documents: use trend reports to reflect the stability of production processes

■ Transfer product specifications and project files to the transmission fog imager i for daily work management

System requirements:

Operating System: Windows 7 SP1 or 8.1 Microsoft. NET Framework 4
Hardware: * Core2 Duo, 2.2GHz, i7, or equivalent configuration

Memory: 4GB RAM, * 8GM hard drive

Hard disk available space: least 300MB

Display: 1280x1024 resolution or higher

Disk drive: CD-ROM or DVD drive

Port: Available USB or LAN ports

standard

ASTM D 1003, D 1044

ISO 13468, 14782

Technical Indicators:

光源 CIE-C, CIE-A (ASTM D1003),CIE-D65 (ISO 13468, ISO 14782)
Spectral response CIE spectral function y
Optical path 0 °/scattering
Measurement area diameter 18 mm (0.7 in)
Sample mouth diameter 25.4 mm (1.0 in)
Measurement range 0-100%
Repeatability ± 0.1 units (standard deviation)

Reproducibility ± 0.4 units (standard deviation)
Memory capacity of 5000 numerical values
Interface LAN, USB2.0, Comes with a front USB port for connecting to a USB flash drive
Power supply 115V/230V, with built-in adapter
Working temperature+10-40 ° C (+50-104 ° F)
Storage temperature 0-50 ° C (+32-122 ° F)
Volume (width x height x depth) 62 x 33 x 22 cm (24 x 13 x9 in)
Weight 18 kg (40 lbs)


Multi purpose sample holder suitable for various special needs

Sample holder suitable for films and sheets, preciseThe track is easy to replace with various sample holders

Special film holder suitable for measuring ultra-thin films

The measurement of fog shadow is used to determine the wear resistance of transparent materials. The fog shadow bracket attachment can be used to place the wear area in the measurement beam

The optical cell and its bracket can be used to measure liquids

Order Information

Model name
4775

Basic configuration:

Host, carrying case, clarity calibration standard board, traceable certificate, foot switch and power cord, USB cable and LAN cable, smart lab haze software, CD with key disk (2 licenses), operation manual;


Optional components and spare parts:

Model name

4784 Thin film bracket, used for 4775Used for very thin films

4785 fog shadow bracket,Used for 4775Used to evaluate the wear resistance ability

4786 transmission cell bracket, used for 4775Used to measure liquids

4788 sample holder, used for 4775Used for films and sheets

4865 BYK Software Smart Lab HazeUsed for professional document analysis and processing

6180 Liquid optical cell, 2.5mm path length 2.5mm, cell width 50mm

6182 Optical cell for liquid, 5 mmPath length 5.0mm, pool width 50mm

6183 Liquid optical cell, 10mm path length 10mm, cell width 50mm

6189 Optical cell for liquid, 20mmPath length 20mm, pool width 50mm

4776 Clarity Calibration Standard Replacement Clarity Standard with Certificate

4777 Clarity Reference Standard Check Clarity Test Standard Pencil with Certificate

4790 Fog Shadow Test Standard 1 Fog Shadow is approximately 1%, for testing purposes, with a certificate

4791 Fog Shadow Test Standard 5 Fog Shadow is approximately 5%, for testing purposes, with certificate

4792 Fog Shadow Test Standard 10 Fog Shadow is approximately 10%, for testing purposes, with certificate

4793 Fog Shadow Test Standard 20 Fog Shadow Approximately 20%, for testing purposes, with certificate

4794 Fog Shadow Test Standard 30 Fog Shadow Approximately 30%, for testing purposes, with certificate

4795 Fog Shadow Test Standard: One set of 5 fog shadows should be placed in a hard box with a certificate

4778 Transmission Standard 10 Full Transmittance Approximately 10%, for testing purposes, with certificate

4779 Transmission Standard 30 Full Transmittance Approximately 30%, for testing purposes, with certificate

4780 transmission standard, 50% full transmittance, approximately 50%, for testing purposes, with certificate

4781 Transmission Standard 70 Full Transmittance Approximately 70%, for testing purposes, with certificate

4782 Transmission Standard 90 Full Transmittance Approximately 90%, for testing purposes, with certificate

A set of 5 transmission standards, including 4783 transmission standards, are placed in a hard box with certificates