Transformer oil dedicated chromatograph

NegotiableUpdate on 02/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

This product is specifically designed for analyzing the content of dissolved gas components. The instrument adopts a three detector process and can complete the full analysis of the content of 9 gas components dissolved in insulating oil within 7 minutes of a single injection

Product Details

GC-9560-HDSpecialized for transformer oilThe chromatograph is a gas chromatograph used for determining the content of dissolved gas components in insulating oil for power use. The instrument adopts a three detector process and is equipped withTCDDetector and twoFIDDetector, one injection7Dissolve in insulating oil within minutes7Full analysis of gas component content, and detection if necessaryO2TheN2The content. among whichH2TheO2TheN2passTCDtesting;COTheCO2passFID1Detection, hydrocarbon gases(CH4TheC2H4TheC2H6TheC2H2)ByFID2Testing has overcome a lot of challengesCOTheCO2The impact on hydrocarbon gases, especially onC2H2The impact has greatly improved the detection sensitivity while shortening the detection time.

1、 Technical parameters:

1. Detection range and detection limit (unit µ L/L):

component Testing Scope
H2 2-10000
CO 2-50000
CO2 2-50000
CH4 0.1-2000
C2H4 0.1-2000
C2H6 0.1-2000
C2H2 0.1-2000

2. Technical specifications of detector:

Thermal conductivity detector(TCD Hydrogen flame ionization detector(FID
Adopting a semi diffusive structure Cylindrical collection electrode structure design, quartz nozzle, responsive
The power supply adopts constant current control mode Automatic ignition; Stable time: Ten minutes
Sensitivity: ≥2500mV·mlmg(Hexadecane)/Isooctane) Detection limit: ≤8×10-12gs(Hexadecane)/Isooctane)
Baseline noise: ≤20μV Baseline noise: ≤2×10-13A
Baseline drift: ≤100μV/30min Baseline drift: ≤2×10-12A/30min
line Sex: ≥104 Linear: ≥106

3. Temperature control indicators:

Temperature control location Temperature control range temperature control accuracy
pillar box At room temperature8~400 ±0.1
Hydrogen flame(FID)Detector At room temperature8~400 ±0.1
hot Guide(TCD)Detector At room temperature8~400 ±0.1
NiCatalytic converter At room temperature8~400 ±0.1

2、 Execution standards:
GB/T 17623-1998 "Determination of dissolved gas components in insulating oil by gas chromatography"
GB/T 7252-2001 "Guidelines for Analysis and Determination of Dissolved Gases in Transformer Oil"



threeComputer anti control function:

After the analysis is completed, multiple fault diagnosis methods are provided, including automatic over limit prompts, three ratio diagnostics that comply with national standards, TD diagrams, component concentration diagrams, David triangles, etc.