Trace oxygen analyzer

NegotiableUpdate on 01/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The HT-LA432 trace oxygen analyzer adopts a * protective gas path to effectively protect the sensor and avoid the sensor's lifespan being affected by prolonged exposure to air; Built in sensor protection device and temperature compensation sensor ensure the service life of the sensor while reducing the impact of changes in sample gas temperature and environment on measurement accuracy; Calibration at any point within the entire range is sufficient, without the need for multi-point calibration, making calibration simple and convenient;

Product Details

HT-LA432 traceoxygen analyzer

Technical Specifications:

  • Measurement principle:fuel cell
  • Display mode320×240dot matrixcolorfulLCD
  • measurementscope0~10/100/1000PPm O2(Trace)

010%/25%O2(Constant)

  • measurement accuracy0~1000PPm/10%/25%±1%FS

0~100PPm±2% FS

0~10PPm±5%FS

  • smallResolution:0.1PPm
  • heavyRestoration:±1.0%FS
  • Response time:T9060S(Trace)

T9040S(Constant)

  • outputinterface4-20mA.DC (non isolated output, load resistance)1KΩ

0-10V.DC (non isolated output, load resistance>10K)Ω

2Programmable dry contact type passive alarm outputContact large capacity AC220V/2A

1-channel instrument status signal output

  • contact methodRS232 (default) or RS485
  • workpower supplyAC100~240V 50/60Hzpower consumption25VA
  • environmenttemperature-10~+50
  • storeambient humidity:90%RH, non condensing
  • workambient humidity:100%RH, non condensing
  • Sample gas temperature: 0~40
  • Sampling method: through type
  • Sample airflowQuantity:400~600mL/min
  • intakepressure:0.05Mpaentrancegauge pressure0.35Mpa, Stable pressure airAtmosphere
  • Exhaust pressure: Free emptying (under safe conditions)
  • Background gasN2inertiaAcidity, reducibility, etcgas
  • Overall dimensions145mm×175mm×233mm(H×W×D)
  • cutout size135mm×135mm(H×W)
  • sensorlifespan24 months(Under normal usage conditions)
  • air circuit interfaceNPT 1/8 internal thread
  • instrument weightNet weight 3.2Kg
  • Installation methodembedded

Instrument features:

  • Chinese English menu switching function, intuitive and convenient operation
  • 320×240 graphic dot matrix color LCD display, with delicate and clear display;
  • Adopting imported fuel cell sensors, it has the characteristics of fast response speed, high measurement accuracy, long calibration cycle, and strong resistance;
  • Adopting a protective air path of * effectively protects the sensor and avoids the sensor's lifespan being affected by prolonged exposure to air;
  • Built in sensor protection device and temperature compensation sensor ensure the service life of the sensor while reducing the impact of changes in sample gas temperature and environment on measurement accuracy;
  • Calibration at any point within the entire range is sufficient, without the need for multi-point calibration, making calibration simple and convenient;
  • 40000 piecesAutomatic data storage function, users can view historical data locally at any time;
  • According to user needs, RS232 (default) or RS485 data communication interfaces can be optionally configuredCan be used with computersOr other digital communication devices directlyPerform one-way or two-way communication.

Application scenarios:

Widely used in online oxygen analysis industries such as petrochemicals, air separation, semiconductor industry protective gas detection, food production process gas detection, and oxygen concentration detection in hydrocarbon gases.

Ordering Instructions(Please specify when placing an order)

lmeasurement range

lTested gas pressure

lBackground gas composition

HT-LA432 traceoxygen analyzer