The GCA1100 online chromatographic analyzer is equipped with an ETC temperature control unit, which adopts electronic closed-loop control and is responsible for constant temperature control of the column box, sampler, detector, etc. The temperature control accuracy can be better than that of the #177; 0.1℃;
GCA1100Online chromatographic analyzer

Technical Specifications:
-
measurementPrinciple:gas phasechromatography
-
Testing method:Hydrogen flame ionization detector(FID)
- Detection types: methane, total hydrocarbons, acetylene, etc. (other components can be customized)
-
measurement range:C2H2:0~10PPm
CXHX:0~100PPm
-
measurement accuracy:C2H2:≤3%FS
CXHX:≤3%FS
-
outputinterface:2road4-20mA. DC(Non isolated output, load resistance)<1KΩ)
acetylene:2Programmable dry contact type passive alarm output,Contact large capacity AC220V/2A
Total hydrocarbons:2Programmable dry contact type passive alarm output,Contact large capacity AC220V/2A
4Road backup port
lother interfaces:RS485serial interfaceThe10/100MetherNetwork portUSB HOSTinterface
-
workpower supply:AC88~264V 50/60HzPower consumption<500VA
-
environmenttemperature:5℃~35℃
-
ambient humidity:<85%RH, non condensing
lAir source requirements:High purity nitrogen gas (concentration)≥99.999%)High purity hydrogen gas(≥99.999%)Zero level air (hydrocarbons<20PPb)
-
intake pressure:(0.4~0.8)Mpa
-
Sample gas conditions:Dew point temperature<-30 ℃ and dust-free
-
Overall dimensions:310mm×483mm×600mm(H×W×D)
-
cutout size:305mm×442mm(H×W)
-
pipe路接口:φ3mmConnectors, optional materials:Polyethylene pipe, polytetrafluoroethylene pipe, stainless steel pipe, copper pipe
-
instrument weight:Net weight28.4Kg
-
Installation method: Embedded/Taiwanese style
Instrument features:
-
Configure ETC temperature control unit, * using electronic closed-loop control, responsible for constant temperature control of column box, sampler, detector, etc., with temperature control accuracy ofsuperior to±0.1℃;
-
OptionalEPC pressure control unit, * using electronic closed-loop control, responsible for carrier gas 1 (acetylene column)backblow)Carrier Gas 2 (Ethyne Column)Sampling+Pre columnbackblow)Carrier gas 3 (total hydrocarbons)Column sampling+total hydrocarbon column blowback)Constant pressure control of gas paths such as hydrogen and air, with precision in pressure controlsuperior to±0.1kPa;
-
Before leaving the factory, the soap film flowmeter was used to calibrate the flow rate in each gas path. The flow rate in each gas path can be set, and the EPC unit will automatically calculate and control the pressure in the gas path to maintain a constant flow rate;
-
Using quantitative methodspipePerform volumetric sampling
High degree, low maintenance, long service life;
-
The use of imported fourteen way automatic switching pneumatic valve for sample injection enables automated control of injection, sampling, and blowback without the need for manual intervention;
-
The stainless steel pipes and quantitative pipes inside the instrument are treated with high-temperature passivation to prevent sample adsorption and improve the repeatability and accuracy of detection;
-
Gas injection adopts a three-way solenoid valve balance connection. At the moment of injection, the quantitative tube is connected to the atmosphere, so that the pressure of the sample gas in the quantitative tube is the same as that of the atmosphere, to ensure the accuracy and stability of the injection volume;
-
Using a hydrogen flame ionization FID detector to detect total hydrocarbons and acetylene has the characteristics of low detection limit, high detection accuracy, and stable performance;
-
When the analyzer is turned on and the analysis software is started,Equipped with automatic pressure control, temperature control, automatic ignition and other functions.Before shutting down, analyze the software when it is closed,It has functions such as automatic heating stop,And these functions can be flexibly configured in the analysis software;
-
The instrument can customize the configuration system according to the user's analysis needs, including temperature, chromatographic column, detector, etc;
-
Automatic calibration function, capable of flexible automatic calibration and quality control points;
-
Built in industrial computer, capable of WIFI wireless networking, and equipped with a 12.1-inch large capacitive touch screen design, the screen is beautiful, simple, and easy to operate;
-
Supports network and serial communication, based on standard protocols such as MODBUS RTU/UDP/TCP, facilitating user integration;
-
Equipped with relay alarm output and 4-20mA signal remote transmission function, easy to interface with user DCS system;
- Test components can be customized according to customer needs.
Application scenarios:
Deep cold air separation industry.
Ordering Notice:
- test object
- Range and detection limit of the tested component
-
Background gas composition
GCA1100Online chromatographic analyzer