Welcome Customer !

Membership

Help

Shanghai Botuo Instrument Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

TN total nitrogen online automatic analyzer

NegotiableUpdate on 01/31
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
TN total nitrogen online automatic analyzer, method basis: * spectrophotometric method; Measurement range: 0.0-10mg/L, 0.5-100 mg/L, 5-500 mg/L
Product Details

TN total nitrogen online automatic analyzer

Model: TNG-3020, Brand: Shanghai Botuo

Technical Indicators:

Method basis: * spectrophotometric method

Measurement range: 0.010mg/L、0.5100 mg/L、5~500 mg/L

Indication error: ≤ 0.5mg/L ± 0.05mg/L;0.5mg/L not exceeding ± 10%;

Repeatability: not exceeding ± 5%;

Stability: not exceeding ± 10% within 24 hours;

Measurement cycle: The small measurement cycle is 30 minutes, and the digestion time can be arbitrarily modified between 5 minutes and 120 minutes;

Sampling period: time interval (adjustable from 10 min to 9999 min) and whole point measurement mode;

Calibration cycle: adjustable at any interval and time from 1 to 99 days;

Maintenance cycle: usually once a month, about 30 minutes each time;

Reagent consumption: less than 0.5 yuan/sample;

Output: 4~20mA (2 channels) RS232, RS485;

Environmental requirements: Indoor with adjustable temperature, recommended temperature range of+5-28 ℃; Humidity ≤ 90% (non condensing);

Power supply: AC220 ± 10% V, 50 ± 10% Hz, 5A;

Dimensions: Height 1570 x Width 500 x Depth 450 mm

Other: Abnormal alarms and power outages will not result in data loss; Touch screen display and command input;

After abnormal reset and power failure, the instrument will automatically discharge residual reactants and restore working status.

  • Building a monitoring station buildingThe area should not be less than 33.5m=10.5m2The specific size will be adjusted based on the number of devices. The monitoring station shouldapproachSampling point(Within 20 meters is preferred). The height of the room floor is 20cm higher than the ground level, and the distance from the pollution source isThe gap is4mwithinThe monitoring station building is not directly constructed above the pollution source (otherwise it will result in severe humidity exceeding the standard). On the side close to the pollution source, leave a diameter close to the ground10 centimetersThe through-hole facilitates the entry and exit of water pipes (each device has 3 water pipes in and out). The monitoring station building is now in a dedicated room, with dedicated personnel for safekeeping and maintenance.
  • This product is easy to measure,The sample to be tested does not require any pre-treatment. Simply insert the water sample lifting tube into the system water sample to measure the total nitrogen concentration. The device has a large measurement range of 0-500mg/L TN, and this method is mainly used for online automatic monitoring of total nitrogen concentration in waste (sewage) discharge point sources, surface water, etc.
  • TN total nitrogen online automatic analyzer