The application of online ammonia nitrogen analyzer is widely used in the inlet and outlet of sewage and water plants; Water quality monitoring stations for reservoirs, water sources, surface water, lakes, and rivers. The instrument monitoring data is stable, accurate, and durable.
Product Features:
Adopting the national standard salicylic acid method, it has high accuracy and good stability;
The structural design of * * has lower failure rates, lower maintenance requirements, lower reagent consumption, and higher cost-effectiveness;
The valve components of ● * and flexible switching of multiple channels make the equipment easy to maintain and have a long service life;
The precise optical system enables accurate measurement of reagents, overcoming quantitative errors caused by wear and tear of peristaltic pumps and pump tubes, and achieving precise quantification of trace reagents, greatly reducing the amount of reagents used;
Power off data protection ensures that instrument system data is not damaged and data records are not lost;
● Multiple signal output interfaces to meet various access requirements;
● It has an over limit alarm function and can be used in conjunction with a sampler to achieve over limit sample retention;
● With network functionality, data sharing and remote control can be achieved through a network platform;
Equipped with a micro printer for easy data storage.
Performance indicators:
1. Measurement range: 0-2mg/L; 0~10mg/L; 0~50mg/L; 0~125mg/L
2. Measurement accuracy: ± 0.03mg/L when ≤ 0.8mg/L; >± 4% at 0.8mg/L
3. Detection limit: 0.01mg/L
4. Zero drift: ± 0.02mg/L
5. Range drift: ± 3% FS
6. Measurement cycle: The small measurement cycle is 20 minutes
7. Calibration: Equipped with online automatic calibration function
8. Automatic cleaning: The instrument automatically cleans the pipeline after each measurement
9. Reagent consumption: 0.7 mL/time/reagent
10. Data storage: 500000 times of historical data storage (full data records for more than ten years)
11. Data protection: Abnormal alarms and power outages will not result in data loss
12. Display: Touch screen display and command input
Output:
Interface output: Standard configuration: RS232/RS485, two 4-20mA channels;
Optional: Wireless IoT interface, linkage control interface
Power supply:
AC power supply: 220 ± 22VAC, 50 ± 2.5Hz
Instrument power: 50W per day;<300W at peak hours
物理性能:
Size: 420 × 600 × 250mm
Environmental performance:
1. Environmental requirements: 5-40 ℃, relative humidity of 80%, no condensation or dew
2. External water sample: pressure: -10 to+2KPa;
3. Flow velocity: -1.0 to 0.5m/s;
4. Temperature: 5-40 ℃