E-mail
jykeyuan@126.com
-
Phone
13901422765
-
Address
No. 998 Tianmu West Road, Jiangyan Economic Development Zone, Jiangsu Province
Jiangsu Keyuan Electronic Instrument Co., Ltd
jykeyuan@126.com
13901422765
No. 998 Tianmu West Road, Jiangyan Economic Development Zone, Jiangsu Province
KY-100 standard COD digesterBy using microelectronics technology for timed control of heating electric furnaces, it is possible to12aColumn typeThe bottle burr reflux tube replaces the ball reflux tube, and the air cooling technology replaces the tap water cooling method, which can save water and standardize the instrument. They can maintain the necessary high temperature for the reaction within the set time to ensure digestion. It can be widely applied in fields such as environmental protection, scientific research monitoring, and production monitoring.
Main features of the instrument:
1.Adhered to the basic principles of ISO and GB standards, ensuring a digestion operation with reflux heating and micro boiling for 2 hours
2.The preparation and dosage of the reagent solution are consistent with the GB method * to ensure reliable and accurate analysis results
3.Simple, accurate analysis results, water conservation, automatic shutdown after completion
4.The standard COD digester follows the basic principles of the ISO standard GB11914-89, ensuring a 2-hour digestion operation with reflux heating and slight boiling. The preparation and addition of reagent solutions are in accordance with the national standard.
5.The instrument adopts a glass burr reflux tube instead of a spherical reflux tube, and uses cold air technology instead of tap water reflux cooling method.
Instrument execution standard:
HJ828-2017 Determination of Chemical Oxygen Demand in Water Quality - Dichromate Method(Alternative)GB11914-89)
Main technical parameters:
1.Sample type: Liquid
2.Measurement range: 10-700mg/L (measured after dilution of water samples greater than 700mg/L)
3.Measurement time: 10 minutes -2 hours and 30 minutes (user adjustable)
4.Measurement error: The relative standard deviation of potassium hydrogen phthalate standard solution (500mg/L) is not more than 5.0%
Industrial organic wastewater (500mg/L) Relative standard deviation not exceeding 8.0%
5.Heating plate: Ceramic heating plate
6.Constant temperature accuracy: ± 1 ℃ 7.Heating time: (180 ℃)<20min
8.Heating power:1000W (AC220V, 50HZ, users can choose their own heating power)
9.Number of Dissolved Samples:12A (using 24 # grinding mouth)pillarShaped bottle)
10. Environmental temperature: ≤ 35 ℃