Standard COD Dissolver (6 Cone Bottles)

NegotiableUpdate on 03/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The KY-100 standard COD digester adopts microelectronics technology for timed control of the heating electric furnace, which can replace the ball reflux tube with 6 conical bottle burr reflux tubes, and replace the tap water cooling method with air cooling technology. It can save water and standardize the instrument. They can maintain the necessary high temperature for the reaction within the set time to ensure * digestion. It can be widely applied in fields such as environmental protection, scientific research monitoring, and production monitoring.
Product Details

KY-100 standard COD digesterUsing microelectronics technology for timed control of the heating electric furnace, it can process 6 conical bottlesMaoThe use of a needle reflux tube instead of a ball reflux tube and air cooling technology instead of tap water cooling can save water and standardize the instrument. They can maintain the necessary high temperature for the reaction within the set time to ensure digestion. It can be widely applied in fields such as environmental protection, scientific research monitoring, and production monitoring.

Main features of the instrument:

1. Adhered to the basic principles of ISO and GB standards, ensuring a digestion operation with reflux heating and micro boiling for 2 hours.

2. The preparation and dosage of the reagent solution are consistent with the GB method * to ensure reliable and accurate analysis results.

3. Simple, accurate analysis results, water conservation, and automatic shutdown after completion.

Instrument execution standard:

HJ828-2017 Determination of Chemical Oxygen Demand in Water Quality - Dichromate Method(Alternative)GB11914-89

Main technical parameters:

1. Sample type: Liquid

2. Measurement range: 16-700mg/L (measured after dilution of water samples greater than 700mg/L)

3. Measurement time: ≤ 2h

4. Measurement error: The relative standard deviation of potassium hydrogen phthalate standard solution (500mg/L) is not more than 5.0% for industrial use

The relative standard deviation of organic wastewater (500mg/L) is not more than 8.0%

5. Environmental temperature: 5-40 ℃

6. Heating temperature: adjustable from 25 ℃ to 170 ℃ (± 1 ℃)

7. Heating time: can be set from 0 to 180 minutes

8. Heating power: 1500W (AC 220 ± 22V, 50HZ)

Instrument system configuration:

Normal configuration: KY-100 standard COD (cr) digester complete set and glass burr reflux tube