Sewage pump: WQK/QG sewage pump with stainless steel blade cutting device

NegotiableUpdate on 03/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The WQK/belt cutting device sewage pump has a particularly strong sewage passing capacity and good cutting performance. It can chop up impurities such as long fibers, plastics, paper, belts, cloth strips, straw, ropes, etc. in the sewage and discharge them. The method used is designed with reasonable hydraulic characteristics, allowing the electric pump to operate at full head. The excellent combination of dry motor and water pump
Product Details
  • Sewage pump, sewage pump with cutting device, submersible sewage pump

    I. Overview
    WQKSewage pump with cutting deviceThe electric pump has a particularly strong ability to discharge pollutants, with good cutting performance. It can chop up impurities such as long fibers, plastics, paper, belts, cloth strips, straw, ropes, etc. in the sewage and discharge them. Using the best * method, it is designed with the most reasonable hydraulic characteristics, so that the electric pump can operate at full head. The best combination of excellent dry motor and water pump makes the total efficiency of the electric pump reach the same level as the ASS belt cutting device series products of West German ABS company. The electric pump adopts high-quality hard alloy, double end mechanical seal and skeleton oil seal assembly surface, which should not exceed 1/2 of the height of the motor, and the temperature of the pumped pollutants should not exceed 40 ℃.

    The WQX series submersible sewage pump is mainly used for discharging domestic wastewater, sewage, human feces and urine, as well as solid suspended solids and non corrosive media containing short fiber paper scraps, sawdust, starch, sediment, ore particles, etc. The temperature of the pumped liquid does not exceed 40 ℃, the density does not exceed 1200kg/m3, and the pH value is about 9. This electric pump adopts a double end mechanical seal and a rotating impeller. The impeller is made of stainless steel, wear-resistant, non clogging, non winding, and has the advantages of small volume, compact structure, and easy portability.

    2、 Scope of application
    WQK/QGSewage pump with cutting deviceMainly used for engineering wastewater and domestic wastewater.
    For example:
    (1) Used for construction sites, engineering foundation construction, municipal facilities, and water treatment plants.
    (2) Sewage discharge from the basement of various high-rise buildings, civil air defense pits, subways, and other underground structures.
    (3) Sewage treatment and circulating water transportation for small and medium-sized enterprises.
    (4) The pumping of slag and slurry from factories and mining enterprises such as food, paper, brewing, steel and non-ferrous metals, leather, textile, pharmaceutical, cement plants, etc.
    (5) Chicken farms, pig farms, various animal husbandry industries, fish ponds used for pumping and cleaning ponds, oxygenation, septic tanks, and other occasions for the transportation of human and animal manure and urine.
    Note: wqkSewage pump with cutting deviceThe main performance and data are the same as those of the wqk/qg type, except for the absence of a cutting device.

    3、 The significance of the model of the sewage pump with cutting device

    4、 Precautions for use

    (1) Before using the electric pump, it is necessary to first check whether the cables are damaged. When handling and installing the water pump, cut iron to pull or damage the cables to prevent accidents caused by cable breakage and water leakage. If the cable cracks hard, it should be replaced immediately. And use a megohmmeter to check if the insulation resistance of the electric pump is normal (the insulation resistance should not be less than 1 megohm)
    (2) Identify the grounding wire (usually yellow or green or marked with a grounding symbol), and follow the prescribed procedures to properly connect the grounding wire. Our factory's grounding wire is equipped with a grounding sign.
    (3) Choose appropriate protectors (such as leakage protectors, air switches, phase failure overcurrent protectors, etc.) and do not directly connect them with knife switches.
    (4) Connect the power cord according to the standard, test the power supply, check if the electric pump is running normally, and determine if the steering is correct. If the steering is incorrect, swap any two of the three power cords (note that the running time should not exceed half a minute).
    (5) Install the water outlet connector and water outlet hose (or iron pipe), tie a rope on the handle of the electric pump (cable cannot replace the function of the hanging rope), place the electric pump into the pump to be pumped, connect the power supply, and it can be used.
    (6) In order to ensure personal safety, it is strictly prohibited to install water operations (such as moving, inspecting, troubleshooting, etc.) near the electric pump during the operation of the electric pump. Contact with the electric pump is necessary to prevent accidents caused by electric pump leakage!
    (7) It is strictly prohibited to expose the entire electric pump to the water surface during operation (or for a short period of time). The "on" and "off" of the electric pump should not be too frequent to prevent motor overheating and damage
    (8) Pumping liquids with high sand content for WQK/QGSewage pump with cutting deviceThe overcurrent components have significant wear and tear, so we use our factory's cyclone sewage submersible electric pump products.
    (9) If WQK/QG is foundSewage pump with cutting deviceDuring operation, if there are abnormal phenomena such as non rotation, tripping of the protector, or blown fuses, the power should be immediately cut off and the wiring of the power protector should be checked for any problems
    If these external devices are all normal, it may be a fault with the electric pump, and it should not be continued to be used to avoid accidents!

    Cause and solution of malfunction

    Fault phenomenon

    cause of failure

    solution

    The electric pump is not running

    The power cord is not properly connected

    Connect the power supply according to standard requirements

    One phase of the power supply is not powered on

    Check the fuse and power supply, connect the three-phase power supply

    Impeller and chassis stuck

    Adjust the chassis clearance between 0.2-0.5mm so that the impeller can be easily moved by hand

    Electric pump burnt out

    Repair the motor again

    Damaged protective device

    repair or replace

    Small water output or insufficient head

    The clearance between the impeller and the chassis is too large

    Adjust the gap to the normal range (0.2-0.5mm)

    The impeller is severely worn out

    Replace the impeller

    The motor speed cannot reach the normal speed

    Replace the motor rotor or repair the voltage

    The power supply voltage is too low

    Adjust the voltage to the rated voltage

    Reduce the voltage drop on the power leads of large cross-section cables (in cases where the power leads are too long)

    Reverse rotation of electric pump

    Swap the two power connectors to make the electric pump rotate forward

    Impurities cannot be cut or
    Poor cutting effect

    The clearance between the impeller and the chassis is too large

    Adjust the gap to the normal range (0.2-0.5mm)

    Cutting blade wear becomes pure

    Replace the impeller and chassis

    Protector is disconnected or
    Connected and then disconnected

    Improper selection or damage of protector

    Re select a suitable protector (the rated current of the protector must match the rated current of the electric pump)

    The insulation resistance of the power motor is too low (less than 0.5M Ω) due to moisture or water leakage

    Remove the motor for drying. If the mechanical seal, sealing ring, or cable sealing head is damaged and leaks water, the damaged sealing components should be replaced

    Short circuit between turns of motor stator coil

    Replace or repair the motor again

    Two phase operation of motor

    Check the power supply or connectors, repair them

    The power supply voltage is too low

    Restore the voltage to normal value

    The electric pump is stuck by impurities

    Clean up impurities

    Excessive viscosity or sand content in water can cause overload operation of the electric pump

    Reduce viscosity or sand content

    bearing damage

    replace the bearing

    model

    traffic
    m3/h

    head
    (m)

    Diameter of outlet piping
    mm

    power
    kw

    speed
    (r/min)

    WQK8-12QG

    8

    12

    32

    0.75

    2900

    WQK20-7QG

    20

    7

    50

    0.75

    1450

    WQK10-12QG

    10

    12

    40

    1.1

    1450

    WQK8-22QG

    8

    22

    25

    1.1

    1450

    WQK20-15QG

    20

    15

    50

    1.5

    1450

    WQK15-30QG

    15

    30

    40

    2.2

    1450

    WQK20-20QG

    20

    20

    50

    2.2

    1450

    WQK25-15QG

    25

    15

    65

    2.2

    1450

    WQK40-7QG

    40

    7

    80

    2.2

    1450

    WQK30-15QG

    30

    15

    80

    3

    2900

    WQK25-30QG

    25

    30

    65

    4

    2900

    WQK40-15QG

    40

    15

    80

    4

    1450

    WQK85-10QG

    82

    10

    100

    4

    1450

    WQK65-25QG

    65

    25

    80

    7.5

    2900

    WQK80-20QG

    80

    20

    80

    7.5

    1450

    WQK100-15QG

    100

    15

    100

    7.5

    1450

    WQK100-25QG

    100

    25

    100

    11

    1450

    WQK115-15QG

    115

    15

    125

    15

    1450

    WQK180-15QG

    180

    15

    150

    15

    1450

  • Related Products
  • GWP不锈钢管道排污泵

    GWP stainless steel pipeline sewage pump

  • ZW型自吸式排污泵|不锈钢自吸式排污泵

    ZW type self-priming sewage pump | stainless steel self-priming sewage pump

  • QW潜水排污泵|潜水式排污泵|不锈钢潜水式排污泵

    QW submersible sewage pump | submersible sewage pump | stainless steel submersible sewage pump

  • QXB型潜水离心式曝气机|潜水曝气机|水下曝气机

    QXB submersible centrifugal aerator | submersible aerator | underwater aerator

  • GW型管道排污泵|管道式无堵塞排污泵

    GW type pipeline sewage pump | pipeline type unobstructed sewage pump

Related articles

  • Overview of sewage pump 2007/8/14
  • Maintenance and upkeep of submersible sewage pumps 2007/8/16
  • Advantages and Application Analysis of Submersible Sewage Pumps 2008/12/2
  • Characteristics and precautions of mechanical seals for submersible sewage pumps on January 11, 2012
  • Layout and Design of Discharge and Absorption Pipelines for Self priming Sewage Pumps on January 11, 2012

Message box
Products of interest: *
Your name: *
Your unit: *
*
Detailed address:
Commonly used:
Any of your requests
Opinions or suggestions:
*
Verification code: *=Please enter the calculation result (fill in Arabic numerals), for example: Three plus four=7