Rotary evaporator

NegotiableUpdate on 01/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

1、 Overview: Rotary evaporator, also known as rotary evaporator or rotary evaporator, works by sealing and pressurizing with a vacuum pump to form a vacuum interface

Product Details

1. Overview:
Rotary evaporator, also known as "rotary evaporator" or "rotary evaporator",Rotary evaporatorThe working principle is to seal and pressurize through a vacuum pump, forming a vacuum interface. At the same time, the water bath is heated at high temperature, and the evaporation bottle is rotated to evenly heat the material, increase the heating area, and form a large area of material film inside the evaporation bottle. The material vapor at high temperature is cooled by a condenser and collected in bottles for recycling. The Jinlan series rotary evaporator is widely used for rapid forwarding of high-dose materials, reflux operations, and sample concentration of trace components. Mainly used for drying, crystallization, concentration, separation, and solvent recovery in industries such as biopharmaceuticals, medicine, industrial and mining chemicals, and disease control testing.

2、 Product features:

Electronic speed controller, with a tilted control panel built into the front end, waterproof and splash proof, ensuring safe operation.
AC induction motor has a long non sparking usage time.
The heating pot and bracket can be moved according to needs.
Manually adjust the plum blossom screws,The tilt angle can be adjusted from 180 ° to 240 °.
Stainless steel uprights and module components, large-diameter polytetrafluoroethylene evaporator tubes, integrated glass condenser.
Optional water oil dual-purpose heating pot.
3、 Technical parameters:
model Specifications lifting method speed Evaporator bottle bottle collection Temperature control range power supply voltage
MRE-2000 2L Manual lifting 0~120r/min 500~3000ml 500~2000ml RT-100℃ 220V
50Hz
MRE-2000S Manual lifting 0~120r/min
ARE-2000M Electric lifting 0~120r/min
ARE-2000A Rocker button 0~200r/min
ARE-2000B Rocker button 0~200r/min
ARE-3000A 3L Rocker button 0~200r/min 500~3000ml 500~2000ml
ARE-3000B Rocker button 0~200r/min
ARE-5000A 5L Electric lifting 0~120r/min 5000ml 3000ml
ARE-10L 10L Electric lifting 0~120r/min 10000ml 5000ml
ARE-20L 20L Electric lifting 0~120r/min 20000ml 5000ml
Note: The speed and material can be customized according to requirements, except for conventional ones.
3、 Operation steps:
1. Wipe and dry glass components, left main body, right sink box.
2. Insert the grinding port on the side of the condenser tube into the PTFE connecting tube on the left side of the machine head, tighten it, and rotate it to make it tight.
3. Unscrew the black nut on the right side of the machine head, place it on the bottleneck of the glass interface, and then put on a nylon clip. Then tighten the black locking nut on the machine head, ensuring it is flat and tight.
4. The inlet and outlet are connected and discharged through leather pipes.
5. Connect the vacuum tube to the vacuum pump.
6. After filling the heater with water, plug the power plug into the corresponding socket behind the host control box.
7. Press the power switch to turn it on (-), turn the speed control knob, and the host will rotate.
8. Press the up and down keys (▲/▼), and the machine head will automatically rise or fall.
9. After filling the sink with water, press the heating switch (-) to set the temperature and automatically control the heating.
10. Adjust the angle of the machine head, first loosen the plum blossom knob on the right side of the column, rotate the main machine head to the appropriate angle, and then tighten it.
11. After completing the trial operation, both the power and heating switches are turned off (O). Unplug the power plug.

4、 Attention:
1. To heat and extract valuable solutions using a rotary evaporator, a simulated process experiment should be conducted first. Once it is confirmed that the equipment meets the experimental requirements, it can be put into normal use.
2. Heater temperature automatic control, digital display. If precise water temperature is required, please use a mercury thermometer to measure it directly.
3. The fuse replacement should first cut off the power before opening the seat cover to replace the fuse.
4. During the operation of the heater, do not touch it with your hands to avoid burns.
5. Prohibited from use in environments with flammable, explosive, acidic, alkaline, and anesthetic gases.
6. Glass components: When there is severe dirt, dilute sulfuric acid can be used for cleaning.
7. Evaporator tube: Normally, it does not need to be disassembled and cleaned. If there is serious dirt, it can be disassembled and cleaned.
8. The boiling water inside the heater should be frequently replaced and cleaned. If the material leaks, the operation should be stopped immediately.
9. If the rotating bottle shakes abnormally or makes noise during rotation, stop the machine first and then check whether the glass interface of the rotating bottle is installed flat and in place.
10. Strictly prohibit dry burning without water!