Pipeline pump: ISWH variable frequency horizontal stainless steel pipeline centrifugal pump

NegotiableUpdate on 03/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
ISWH stainless steel centrifugal pump is used for conveying liquids that do not contain solid particles, are corrosive, and have a viscosity similar to water. It is suitable for industries such as petrochemicals, metallurgy, power, papermaking, food and pharmaceuticals, and synthetic fibers. The operating temperature is -20~C~+120 ℃
Product Details

SW single-stage stainless steel horizontal pipeline centrifugal pump
Product Overview:
ISWH horizontal pipeline centrifugal pump Chinese standard name: ISWH single-stage single suction horizontal stainless steel pipeline centrifugal pump (referred to as) stainless steel centrifugal pump
ISWH stainless steel centrifugal pump is used for conveying liquids that do not contain solid particles, are corrosive, and have a viscosity similar to water. It is suitable for industries such as petrochemicals, metallurgy, power, papermaking, food and pharmaceuticals, and synthesis. The operating temperature is -20~C~+120 ℃
Model meaning:


ISW pipeline pump structure diagram and material list:

serial number

1

2

3

4

5

6

7

8

name

base

pump body

impeller

pump cover

mechanical seal

pump shaft

water retaining ring

motor

material

HT200

HT200

HT200

HT200

silicon carbide

VS Graphite

45#

1Cr13

丁青

rubber

tetrafluoro

rubber

Y、Y2

Customized materials

1Cr18Ni9 stainless steel 304, 316, 316L

hard

合金

YB type

List of impeller, mechanical seal material, and water pump operating temperature:

Impeller structure Mechanical seal material Operating temperature
Fully enclosed centrifugal impeller cemented carbide ISW regular type -15 ℃ to+80 ℃
EPDM (Ethylene Propylene Diene Monomer) IRWR hot water type -15 ℃ to+120 ℃
fluororubber ISWH anti-corrosion type -15 ℃ to+120 ℃
Polytetrafluoroethylene  
ceramics  

ISWH single-stage horizontal stainless steel pipeline centrifugal pump is suitable for conveying media and scope:
Water supply system: pressurized water supply for high-rise buildings, municipal pipeline transportation, daily living water, boiler water supply, air conditioning circulation transportation, etc.
Fire fighting system: water supply for fire fighting system of high and low buildings, fire pressurization, fire sprinkler, fire pressure stabilization, fire foam liquid transportation, etc.
Industrial systems: transportation and discharge of acids, alkalis, and chemically corrosive liquids.
Water treatment system: ultrafiltration system, filter press backwash conveying, distillation system water supply, separator water supply, swimming pool circulating water, etc.
Agricultural irrigation: farmland irrigation, sprinkler irrigation, drip irrigation, etc.
Application areas: supporting living quarters, urban water supply and drainage, garden irrigation, fire pressure boosting, chemical metallurgy, food, pharmaceutical and other mechanical equipment.

Comparison diagram of ISWH horizontal pipeline centrifugal pump and IS (IH) horizontal centrifugal pump:

call, name, say, weigh

Yangtze River ISW single-stage horizontal pipeline centrifugal pump

IS (IH) single-stage horizontal centrifugal pump

comparison chart

impeller

·The hydraulic model designed with CAD optimization is efficient, energy-saving, and has good anti cavitation performance;

·Adopting precision casting, smooth flow channel, high efficiency, and long service life;

·Using * balance technology, the operation is smoother and the vibration is smaller.

·Hydraulic performance and anti cavitation performance are not as good as the Yangtze River ISW centrifugal pump

·The smoothness, efficiency, and service life of the flow channel are not as good as those of the Yangtze River ISW centrifugal pump

·The smoothness of operation is not as good as that of the Yangtze River ISW centrifugal pump

pump body

·The hydraulic model optimized with CAD design is efficient and energy-saving;

·Adopting precision casting, smooth flow channel, high efficiency, and long service life;

·Hydraulic performance is not as good as the Yangtze River ISW centrifugal pump

·The smoothness of the flow channel is not as good as the efficiency of the Yangtze River ISW centrifugal pump

overall structure

·The maintenance and repair parts of the water pump in the later stage are replaced less frequently, and the maintenance cost is low

The maintenance cost is expensive

Infrastructure investment

ISW centrifugal pump is directly connected to the motor, simplifying the intermediate transmission structure and reducing infrastructure investment by 20% compared to IS centrifugal pump

·Infrastructure investment is 20% higher than ISW centrifugal pump

procurement cost

·*Strategy to reduce intermediate procurement costs

·Basically the same

quality assurance period

·Yangtze River pipeline pump for 14 months

·Other brands of pipeline pumps for 12 months

Performance parameter table:

model

caliber

traffic

head

efficiency

speed

Motor power

Required cavitation allowance

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

15-80

15

1.1
1.5
2.0

0.3
0.42
0.55

8.5
8
7

26
34
34

2800

0.18

2.3

20-110

20

1.8
2.5
3.3

0.5
0.69
0.91

16
15
13.5

25
34
35

2800

0.37

2.3

20-160

20

1.8
2.5
3.3

0.5
0.69
0.91

33
32
30

19
25
23

2900

0.75

2.3

25-110

25

2.8
4
5.2

0.78
1.11
1.44

16
15
13.5

34
42
41

2900

0.55

2.3

25-125

25

2.8
4
5.2

0.78
1.11
1.44

20.6
20
18

28
36
35

2900

0.75

2.3

25-125A

25

2.5
3.6
4.6

0.69
1.0
1.28

17
16
14.4

35

2900

0.55

2.3

25-160

25

2.8
4
5.2

0.78
1.11
1.44

33
32
30

24
32
33

2900

1.5

2.3

25-160A

25

2.6
3.7
4.9

0.12
1.03
1.36

29
28
26

31

2900

1.1

2.3

model

caliber

traffic

head

efficiency

speed

Motor power

Required cavitation allowance

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

32-100(I)

32

4.4
6.3
8.3

1.22
1.75
2.32

13.2
12.5
11.3

48
54
53

2900

0.75

2.0

32-125

32

3.5
5
6.5

0.97
0.39
1.8

22
20
18

40
44
42

2900

0.75

2.3

32-125A

32

3.1
4.5
5.8

0.86
1.25
1.61

17.6
16
14.4

43

2900

0.55

2.3

32-160(I)

32

4.4
6.3
8.3

1.22
1.75
2.32

33.2
32
30.2

34
40
42

2900

2.2

2.0

32-200(I)

32

4.4
6.3
8.3

1.22
1.75
2.32

50.5
50
48

26
33
35

2900

4

2.0

32-200A

32

2.8
4
5.2

0.78
1.11
1.44

44.6
44
42.7

34
40
42

2900

2.2

2.0

model

caliber

traffic

head

efficiency

speed

Motor power

Required cavitation allowance

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

40-100

40

4.4
6.3
8.3

1.22
1.75
2.31

13.2
12.5
11.3

48
54
53

2900

0.55

2.3

40-100A

40

3.9
5.6
7.4

1.08
1.56
2.06

10.6
10
9

52

2900

0.37

2.3

40-125

40

4.4
6.3
8.3

1.22
1.75
2.31

21
20
18

41
46
43

2900

1.1

2.3

40-125A

40

3.9
5.6
7.4

1.08
1.56
2.06

17.6
16
14.4

40
45
41

2900

0.75

2.3

40-160

40

4.4
6.3
8.3

1.22
1.75
2.31

33
32
30

35
40
40

2900

2.2

2.3

40-160A

40

4.1
5.9
7.8

1.14
1.64
2.17

29
28
26.3

34
39
39

2900

1.5

2.3

40-160B

40

3.8
5.5
7.2

1.06
1.53
2.0

25.5
24
22.5

34
38
37

2900

1.1

2.3

40-200

40

4.4
6.3
8.3

1.22
1.75
2.31

51
50
48

26
33
32

2900

4

2.3

40-200A

40

4.1
5.9
7.8

1.14
1.64
2.17

45
44
42

26
31
30

2900

3

2.3

40-200B

40

3.7
5.3
7.0

1.03
1.47
1.94

38
36
34.5

29

2900

2.2

2.3

40-250

40

4.4
6.3
8.3

1.22
1.75
2.31

82
80
74

24
28
28

2900

7.5

2.3

40-250A

40

4.1
5.9
7.8

1.14
1.64
2.17

72
70
65

24
28
27

2900

5.5

2.3

40-250B

40

3.8
5.5
7.0

1.06
1.53
1.94

61.5
60
56

23
27
26

2900

4

2.3

model

caliber

traffic

head

efficiency

speed

Motor power

Required cavitation allowance

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

40-100(I)

40

8.8
12.5
16.3

2.44
3.47
4.53

13.2
12.5
11.3

55
62
60

2900

1.1

2.3

40-100(I)A

40

8
11
14.5

2.22
3.05
4.03

10.6
10
9

60

2900

0.75

2.3

40-125(I)

40

8.8
12.5
16.3

2.44
3.47
4.53

21.2
20
17.8

49
58
57

2900

1.5

2.3

40-125(I)A

40

8
11
14.5

2.22
3.05
4.03

17
16
14

57

2900

1.1

2.3

40-160(I)

40

8.8
12.5
16.3

2.44
3.47
4.53

33
32
30

45
52
51

2900

3

2.3

40-160(I)A

40

8.2
11.7
15.2

2.28
3.25
4.22

29
28
26

44
51
50

2900

2.2

2.3

40-160(I)B

40

7.3
10.4
13.5

2.38
2.89
3.75

23
22
20.5

50

2900

1.5

2.3

40-200(I)

40

8.8
12.5
16.3

2.44
3.47
4.53

51.2
50
48

38
46
46

2900

5.5

2.3

40-200(I)A

40

8.3
11.7
15.3

2.31
3.25
4.25

45.0
44
42

37
45
45

2900

4

2.3

40-200(I)B

40

7.5
10.6
13.8

2.08
2.94
3.83

37
36
34

44

2900

3

2.3

40-250(I)

40

8.8
12.5
16.3

2.44
3.47
4.53

81.2
80
77.5

31
38
40

2900

11

2.3

40-250(I)A

40

8.2
11.6
15.2

2.28
3.22
4.22

71.0
70
68

38

2900

7.5

2.3

40-250(I)B

40

7.6
10.8
14

2.11
3.0
3.89

61.4
60
58

37

2900

7.5

2.3

40-250(I)C

40

7.1
10.0
13.1

1.97
2.78
3.64

53.2
52
50.4

36

2900

5.5

2.3

model

caliber

traffic

head

efficiency

speed

Motor power

Required cavitation allowance

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

50-100

50

8.8
12.5
16.3

2.44
3.47
4.53

13.6
12.5
11.3

55
62
60

2900

1.1

2.3

50-100A

50

8
11
14.5

2.22
3.05
4.03

11
10
9

60

2900

0.75

2.3

50-125

50

8.8
12.5
16.3

2.44
3.47
4.53

21.5
20
17.8

49
58
57

2900

1.5

2.3

50-125A

50

8
11
14.5

2.22
3.05
4.03

17
16
14

57

2900

1.1

2.3

50-160

50

8.8
12.5
16.3

2.44
3.47
4.53

33
32
30

45
52
51

2900

3

2.3

50-160A

50

8.2
11.7
15.2

2.28
3.25
4.22

29
28
26

44
51
50

2900

2.2

2.3

50-160B

50

7.3
10.4
13.5

2.38
2.89
3.75

23
22
20.5

50

2900

1.5

2.3

50-200

50

8.8
12.5
16.3

2.44
3.47
4.53

52
50
48

38
46
46

2900

5.5

2.3

50-200A

50

8.3
11.7
15.3

2.31
3.25
4.25

45.8
44
42

37
45
45

2900

4

2.3

50-200B

50

7.5
10.6
13.8

2.08
2.94
3.83

37
36
34

44

2900

3

2.3

50-250

50

8.8
12.5
16.3

2.44
3.47
4.53

82
80
77.5

29
38
40

2900

11

2.3

50-250A

50

8.2
11.6
15.2

2.28
3.22
4.22

71.5
70
68

38

2900

7.5

2.3

50-250B

50

7.6
10.8
14

2.11
3.0
3.89

61.4
60
58

37

2900

7.5

2.3

50-250C

50

7.1
10.0
13.1

1.97
2.78
3.64

53.2
52
50.4

36

2900

5.5

2.3

model

caliber

traffic

head

efficiency

speed

Motor power

Required cavitation allowance

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

50-100(I)

50

17.5
25
32.5

4.86
6.94
9.03

13.7
12.5
10.5

67
69
69

2900

1.5

2.5

50-100(I)A

50

15.6
22.3
29

4.3
6.19
8.1

11
10
8.4

65
67
68

2900

1.1

2.5

50-125(I)

50

17.5
25
32.5

4.86
6.94
9.03

21.5
20
18

60
68
67

2900

3

2.5

50-125(I)A

50

15.6
22.3
29

4.33
6.19
8.1

17
16
13.6

58
66
65

2900

2.2

2.5

50-160(I)

50

17.5
25
32.5

4.68
6.94
9.03

34.4
32
27.5

54
63
60

2900

4

2.5

50-160(I)A

50

16.4
23.4
30.4

4.56
6.5
8.44

30
28
24

54
62
59

2900

4

2.5

50-160(I)B

50

15.0
21.6
28

4.17
6.0
7.78

26
24
20.6

58

2900

3

2.5

50-200(I)

50

17.5
25
32.5

4.86
6.94
9.03

52.7
50
45.5

49
58
59

2900

7.5

2.5

50-200(I)A

50

16.4
23.5
30.5

4.56
6.53
8.47

46.4
44
40

48
57
58

2900

7.5

2.5

50-200(I)B

50

15.2
21.8
28.3

4.22
6.06
7.86

40
38
34.5

55

2900

5.5

2.5

50-250(I)

50

17.5
25
32.5

4.86
6.94
9.03

82
80
76.5

39
50
52

2900

15

2.5

50-250(I)A

50

16.4
23.4
30.5

4.56
6.5
8.47

71.5
70
67

39
50
52

2900

11

2.5

50-250(I)B

50

15
21.6
28

4.17
6.0
7.78

61
60
57.4

38
49
54

2900

11

2.5

50-315(I)

50

17.5
25
32.5

4.86
6.94
9.03

128
125
122

30
40
44

2900

30

2.5

50-315(I)A

50

16.6
23.7
31

4.61
6.58
8.6

115
113
110

30
40
44

2900

22

2.5

50-315(I)B

50

15.7
22.5
29.2

4.36
6.25
8.0

103
101
98

39

2900

18.5

2.5

50-315(I)C

50

14.4
20.6
26.8

4.0
5.72
7.44

86
85
83

38

2900

15

2.5

model

caliber

traffic

head

efficiency

speed

Motor power

Required cavitation allowance

m3/h

L/S

m

%

r/min

KW

(NPSH)r

65-100

65

17.5
25
32.5

4.86
6.94
9.03

13.7
12.5
10.5

67
69
69

2900

1.5

2.5

65-100A

65

15.6
22.3
29

4.3
6.19
8.1

11
10
8.4

65
67
68

2900

1.1

2.5

65-125

65

17.5
25
32.5

4.86
6.94
9.03

21.5
20
18

60
68
67

2900

3

2.5

65-125A

65

15.6
22.3
29

4.33
6.19
8.1

17
16
14.4

58
66
65

2900

2.2

2.5

65-160

65

17.5
25
32.5

4.86
6.94
9.03

34.4
32
27.5

54
63
60

2900

4

2.5

65-160A

65

16.4
23.4
30.4

4.56
6.5
8.44

30
28
24

54
62
59

2900

4

2.5

65-160B

65

15.0
21.6
28

4.17
6.0
7.78

26
24
20.6

58

2900

3

2.5

65-200

65

17.5
25
32.5

4.86
6.94
9.03

52.7
50
45.5

49
58
59

2900

7.5

2.5

65-200A

65

16.4
23.5
30.5

4.56
6.53
8.47

46.4
44
40

48
57
58

2900

7.5

2.5

65-200B

65

15.2
21.8
28.3

4.22
6.06
7.86

40
38
34.5

55

2900

5.5

2.5

65-250

65

17.5
25
32.5

4.86
6.94
9.03

82
80
76.5

39
50
52

2900

15

2.5

65-250A

65

16.4
23.4
30.5

4.56
6.5
8.47

71.5
70
67

39
50
52

2900

11

2.5

65-250B

65

15
21.6
28

4.17
6.0
7.78

61
60
57.4

38
49
54

2900

11

2.5

65-315

65

17.5
25
32.5

4.86
6.94
9.03

127
125
122

32
40
44

2900

30

2.5

65-315A

65

16.6
23.7
31

4.61
6.58
8.6

115
113
110

32
40
44

2900

22

2.5

65-315B

65

15.7
22.5
29.2

4.36
6.25
8.0

103
101
98

39

2900

18.5

2.5

65-315C

65

14.4
20.6
26.8

4.0
5.72
7.44

86
85
83

38

2900

15

2.5

model

caliber

traffic

head

efficiency

speed

Motor power

Required cavitation allowance

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

65-100(I)

65

35
50
65

9.72
13.9
18.1

13.8
12.5
10

67
73
70

2900

3

3.0

65-100(I)A

65

31.3
44.7
58

8.7
12.4
16.1

11
10
8

66
72
69

2900

2.2

3.0

65-125(I)

65

35
50
65

9.72
13.9
18.1

22
20
17

67
72.5
70

2900

5.5

3.0

65-125(I)A

65

31.3
44.7
58

8.7
12.5
16.1

17.5
16
13.6

66
71
69

2900

4

3.0

65-160(I)

65

35
50
65

9.72
13.9
18.1

35
32
28

63
71
70

2900

7.5

3.0

65-160(I)A

65

32.7
46.7
61

9.1
13.0
16.9

30.6
28
24

62
70
69

2900

7.5

3.0

65-160(I)B

65

30.3
43.3
56.3

8.4
12.0
15.6

26
24
21

69

2900

5.5

3.0

65-200(I)

65

35
50
65

9.72
13.9
18.1

53.5
50
46

55
67
68

2900

15

3.0

65-200(I)A

65

32.8
47
61

9.1
13.1
16.9

47
44
40

54
66
67

2900

11

3.0

65-200(I)B

65

30.5
43.5
56.6

8.5
12.1
15.7

40.6
38
33.4

65

2900

7.5

3.0

65-250(I)

65

35
50
65

9.72
13.9
18.1

83
80
72

52
59
60

2900

22

3.0

65-250(I)A

65

32.5
46.7
61

9.0
13.0
16.9

73
70
63

52
59
60

2900

18.5

3.0

65-250(I)B

65

30
43.3
56

8.3
12.0
15.6

62
60
54

58

2900

15

3.0

65-315(I)

65

35
50
65

9.72
13.9
18.1

128
125
121

44
54
57

2900

37

3.0

65-315(I)A

65

32.5
46.5
60.5

9.0
12.9
16.8

112.6
110
106.4

43
54
57

2900

30

3.0

65-315(I)B

65

31
44.5
58

8.6
12.4
16.1

102.5
100
98

53

2900

30

3.0

65-315(I)C

65

29
41
53.6

8.1
11.4
14.9

87
85
83

51

2900

22

3.0

model

caliber

traffic

head

efficiency

speed

Motor power

Required cavitation allowance

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

80-100

80

35
50
65

9.72
13.9
18.1

13.8
12.5
10

67
73
70

2900

3

3.0

80-100A

80

31.3
44.7
58

8.7
12.5
16.1

11
10
8

66
72
69

2900

2.2

3.0

80-125

80

35
50
65

9.72
13.9
18.1

22
20
17

67
72.5
70

2900

5.5

3.0

80-125A

80

31.3
45
58

8.7
12.5
16.1

17.5
16
13.6

66
71
69

2900

4

3.0

80-160

80

35
50
65

9.72
13.9
18.1

35
32
28

63
71
70

2900

7.5

3.0

80-160A

80

32.7
46.7
61

9.1
13.0
16.9

30.6
28
24

62
70
69

2900

7.5

3.0

80-160B

80

30.3
43.3
56.3

8.4
12.0
15.6

26
24
21

69

2900

5.5

3.0

80-200

80

35
50
65

9.72
13.9
18.1

53.5
50
46

55
67
68

2900

15

3.0

80-200A

80

32.8
47
61

9.1
13.1
16.9

47
44
40

54
66
67

2900

11

3.0

80-200B

80

30.5
43.5
56.6

8.5
12.1
15.7

40.6
38
33.4

65

2900

7.5

3.0

80-250

80

35
50
65

9.72
13.9
18.1

83
80
72

52
59
60

2900

22

3.0

80-250A

80

32.5
46.7
61

9.0
13.0
16.9

73
70
63

52
59
60

2900

18.5

3.0

80-250B

80

30
43.3
56

8.3
12.0
15.6

62
60
54

58

2900

15

3.0

80-315

80

35
50
65

9.72
13.9
18.1

128
125
122

43
54
57

2900

37

3.0

80-315A

80

32.5
46.5
60.5

9.0
12.9
16.8

112.6
110
107.4

43
54
57

2900

30

3.0

80-315B

80

31
44.5
58

8.6
12.4
16.1

102.5
100
98

53

2900

30

3.0

80-315C

80

29
41
53.6

8.1
11.4
14.9

98
85
83

51

2900

22

3.0

80-350

80

35
50
65

9.72
13.9
18.1

146
150
142

55
66
67

2900

55

3.0

80-350A

80

31
44.5
58

8.6
12.4
16.1

138.4
142
134.8

65

2900

45

3.0

80-350B

80

29
41
53.6

8.1
11.4
14.9

131.4
135
127.8

63

2900

37

3.0

model

caliber

traffic

head

efficiency

speed

Motor power

Required cavitation allowance

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

80-100(I)

80

70
100
130

19.4
27.8
36.1

13.6
12.5
11

66
76
75

2900

5.5

4.5

80-100(I)A

80

62.6
89
116

17.4
24.7
32.2

11
10
8.8

64
74
74

2900

4

4.5

80-125(I)

80

70
100
130

19.4
27.8
36.1

23.5
20
14

70
76
65

2900

11

4.5

80-125(I)A

80

62.6
89
116

17.4
24.7
32.2

19
16
11

68
74
65

2900

7.5

4.5

80-160(I)

80

70
100
130

19.4
27.8
36.1

36.5
32
24

70
76
65

2900

15

4.5

80-160(I)A

80

65.4
93.5
121.6

18.2
26.0
33.8

32
28
21

68
74
67

2900

11

4.5

80-160(I)B

80

60.6
86.6
112.5

16.8
24.1
31.3

72
24
18

72

2900

11

4.5

80-200(I)

80

70
100
130

19.4
27.8
36.1

54
50
42

65
74
73

2900

22

4.0

80-200(I)A

80

65.4
93.5
121.6

18.2
26.0
33.8

47.5
44
37

64
73
72

2900

18.5

4.0

80-200(I)B

80

61
87
113

16.9
24.2
31.4

41
38
32

71

2900

15

4.0

80-250(I)

80

70
100
130

19.4
27.8
36.1

87
80
68

62
69
68

2900

37

4.0

80-250(I)A

80

65.4
93.5
121.6

18.2
26.0
33.8

76
70
59.5

61
68
67

2900

30

4.0

80-250(I)B

80

61
87
113

16.9
24.2
31.4

65
60
51

66

2900

30

4.0

80-315(I)

80

70
100
130

19.4
27.8
36.1

132
125
114

55
66
67

2900

75

4.0

80-315(I)A

80

66.5
95
123.6

18.5
26.4
34.3

119
113
103

55
66
67

2900

55

4.0

80-315(I)B

80

63
90
117

17.5
25
32.5

106.6
101
92

65

2900

45

4.0

80-315(I)C

80

58
82
107

16.1
22.8
29.7

90
85
76

63

2900

37

4.0

model

caliber

traffic

head

efficiency

speed

Motor power

Required cavitation allowance

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

100-100

100

70
100
130

19.4
27.8
36.1

13.6
12.5
11

66
76
75

2900

5.5

4.5

100-100A

100

62.6
89
116

17.4
47
32.2

11
10
8.8

64
74
74

2900

4

4.5

100-125

100

70
100
130

19.4
27.8
36.1

23.5
20
14

70
76
65

2900

11

4.5

100-125A

100

62.6
89
116

17.4
24.7
32.2

19
16
11

68
74
63

2900

7.5

4.5

100-160

100

70
100
130

19.4
27.8
36.1

36.5
32
24

70
76
65

2900

15

4.5

100-160A

100

65.4
93.5
121.6

18.2
26.0
33.8

32
28
21

68
74
67

2900

11

4.5

100-160B

100

60.6
86.6
112.5

16.8
24.1
31.3

27
24
18

72

2900

11

4.5

100-200

100

70
100
130

19.4
27.8
36.1

54
50
42

65
74
73

2900

22

4.0

100-200A

100

65.4
93.5
121.6

18.2
26.0
33.8

47.5
44
37

64
73
72

2900

18.5

4.0

100-200B

100

61
87
113

16.9
24.2
31.4

41
38
32

71

2900

15

4.0

100-250

100

70
100
130

19.4
27.8
36.1

37
80
68

62
69
68

2900

37

4.0

100-250A

100

65.4
93.5
121.6

18.2
26.0
33.8

76
70
59.5

61
68
67

2900

30

4.0

100-250B

100

61
87
113

16.9
24.2
31.4

65
60
51

66

2900

30

4.0

100-315

100

70
100
130

19.4
27.8
36.1

132
125
114

55
66
67

2900

75

4.0

100-315A

100

66.5
95
123.6

18.5
26.4
34.3

119
113
103

65
66
67

2900

55

4.0

100-315B

100

63
90
117

17.5
25
32.5

106.6
101
92

65

2900

45

4.0

100-315C

100

58
82
107

16.1
22.8
29.7

90
85
76

63

2900

37

4.0

model

caliber

traffic

head

efficiency

speed

Motor power

Required cavitation allowance

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

100-100(I)

100

96
160
192

26.7
44.4
53.3

14
12.5
10

64
73
70

2900

11

4.5

100-125(I)

100

96
160
192

26.7
44.4
53.3

24
20
14

62
74
69

2900

15

4.5

100-125(I)A

100

84
140
168

23.3
39
46.7

20
17
12

64
72
68

2900

11

4.5

100-160(I)

100

96
160
192

26.7
44.4
53.3

36
32
27

69
79
75

2900

22

5.6

100-160(I)A

100

84
140
168

23.3
39
46.7

32
28
23.5

66
76
72

2900

18.5

5.0

100-200(I)

100

96
160
192

26.7
44.4
53.3

53
50
45

69
79
78

2900

37

5.2

100-200(I)A

100

84
140
168

23.3
39
46.7

48
45
40

64
74
73

2900

30

4.5

100-200(I)B

100

60
100
120

16.7
27.8
33.3

43
40
36

72

2900

22

4.5

100-250(I)

100

96
160
192

26.7
44.4
53.3

83
80
72

65
77
74

2900

55

4.8

100-250(I)A

100

84
140
168

23.3
39
46.7

75
72
65

60
72
69

2900

45

4.5

100-250(I)B

100

60
100
120

16.7
27.8
33.3

68
65
58

70

2900

37

4.5

100-350

100

60
100
120

16.7
27.8
33.3

153.6
150
142

72
57
74

2900

90

4.0

100-350A

100

61
87
113

16.9
24.2
31.4

145.6
142
134

75

2900

75

4.0

100-350B

100

58
82
107

16.1
22.8
29.7

138.6
135
127

75

2900

55

4.0

model

caliber

traffic

head

efficiency

speed

Motor power

Required cavitation allowance

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

125-100

125

96
160
192

26.7
44.4
53.3

13
12.5
12

82

2900

11

4.0

125-100A

125

86
143
172

23.9
39.7
47.8

10.4
10
9.6

77

2900

7.5

4.0

125-125

125

96
160
192

26.7
44.4
53.3

22.6
20
17

80

2900

15

4.0

125-125A

125

86
143
172

23.9
39.7
47.8

18
16
13.6

77

2900

11

4.0

125-160

125

96
160
192

26.7
44.4
53.3

36
32
28

78

2900

22

4.0

125-160A

125

90
150
180

25
41.7
50

31.5
28
24.5

76

2900

18.5

4.0

125-160B

125

83
138
166

21.7
38.3
46.1

27
24
21

73

2900

15

4.0

125-200

125

96
160
192

26.7
44.4
53.3

55
50
46

77

2900

37

5.5

125-200A

125

90
150
180

25
41.7
50

48.4
44
40.5

76

2900

30

5.5

125-200B

125

83
138
166

21.7
38.3
46.1

41.3
37.5
34.5

75

2900

22

5.5

125-250

125

96
160
192

26.7
44.4
53.3

87
80
73

75

2900

55

5.0

125-250A

125

90
150
180

25
41.7
50

76
70
84

74

2900

45

5.5

125-250B

125

83
138
166

21.7
38.3
46.1

65
60
55

73

2900

37

5.5

125-315

125

96
160
192

26.7
44.7
53.3

133
125
119

70

2900

90

5.0

125-315A

125

90
150
180

25
41.7
50

117
110
104.6

70

2900

75

5.0

125-315B

125

86
143
172

23.9
39.7
47.8

106.4
100
95.2

69

2900

75

5.0

125-315C

125

80.5
134
161

22.4
37.2
44.7

96
88
86

67

2900

55

5.0

model

caliber

traffic

head

efficiency

speed

Motor power

Required cavitation allowance

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

150-125

150

96
160
192

26.7
44.4
53.3

22.6
24
17

66
76
76

2900

11

4.0

150-125A

150

90
150
180

25
41.7
50

18
16
13.6

77

2900

7.5

4.0

150-160

150

96
160
192

26.7
44.4
53.3

36
32
27

75

2900

22

4.0

150-160A

150

90
150
180

25
41.7
50

32
28
23.5

76

2900

18.5

4.0

150-160B

150

84
140
168

23.3
39
46.7

27
24
21

73

2900

15

4.0

150-200

150

140
200
260

38.9
55.6
72.2

13.8
12.5
10.6

68
78
78

1450

15

3.0

150-200A

150

125
176
232.5

34.7
49.7
64.6

11
10
8.5

66
76
76

1450

11

3.0

150-200B

150

84
140
168

23.3
39
46.7

41
38
34

75

2900

22

4.0

150-250

150

140
200
260

38.9
55.6
72.2

21.8
20
17

73
79
77

1450

18.5

3.0

150-250A

150

129
184.4
240

35.8
51.2
66.7

18.5
17
14.4

72
78
76

1450

15

3.0

150-250B

150

117
167
217.5

32.5
46.4
60.4

15.2
14
12

76

1450

11

3.0

150-315

150

140
200
260

38.9
55.6
72.2

33.8
32
28

70
78
73

1450

30

2.5

150-315A

150

131
187
243

36.4
51.9
67.5

29.5
28
24.5

69
77
77

1450

22

3.5

150-315B

150

121
173
225

33.5
48.1
62.5

25
24
21

76

1450

18.5

3.5

150-350

150

96
160
192

26.7
44.4
53.3

153.6
150
142.8

80

2900

110

5.5

150-350A

150

90
150
180

25
41.7
50

145.6
142
134.8

70

2900

90

5.2

150-350B

150

84
140
168

23.3
39
46.7

138.6
135
127.8

65
76
74

2900

75

5.5

150-400

150

140
200
260

38.9
55.6
72.2

53
50
44

68
75
71

1450

45

3.5

150-400A

150

131
187
243

36.4
51.9
67.5

46.6
44
38.3

67
74
70

1450

37

3.5

150-400B

150

122
174
226.5

33.9
48.3
62.9

40
38
33

73

1450

30

3.5

150-400C

150

112
160
208

31.1
44.4
57.8

34
32
28

71

1450

22

3.5

model

caliber

traffic

head

efficiency

speed

Motor power

Required cavitation allowance

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

150-250(I)

150

120
200
240

33.3
55.6
66.7

87
80
72

65
76
74

2900

75

4.5

150-250(I)A

150

112
187
224

31.1
51.9
62.2

76
70
63

64
75
73

2900

55

4.5

150-250(I)B

150

104
173
208

28.9
48.1
57.8

65
60
54

63
74
72

2900

45

4.5

150-315(I)

150

120
200
240

33.3
55.6
66.7

133
125
120

58
73
75

2900

110

4.5

150-315(I)A

150

112
187
224

31.1
51.9
62.2

116
110
105

57
72
74

2900

90

4.5

150-315(I)B

150

104
173
208

28.9
48.1
57.8

100
95
91

55
70
72

2900

75

4.5

model

caliber

traffic

head

efficiency

speed

Motor power

Required cavitation allowance

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

200-200

200

140
200
260

38.9
55.6
72.2

13.8
12.5
10.6

68
78
78

1450

15

3.0

200-200A

200

125
179
232.5

34.7
49.7
64.6

11
10
8.5

66
76
76

1450

11

3.0

200-250

200

140
200
260

21.8
20
17

21.8
20
17

73
79
77

1450

18.5

3.0

200-250A

200

129
184.4
240

18.5
17
14.4

18.5
17
14.4

72
78
76

1450

15

3.0

200-250B

200

117
167
217.5

15.2
14
12

15.2
14
12

76

1450

11

3.0

200-315

200

140
200
260

33.8
32
28

33.8
32
28

70
78
78

1450

30

3.5

200-315A

200

131
189
243

29.5
28
24.5

29.5
28
24.5

69
77
77

1450

22

3.5

200-315B

200

121
173
225

25
24
21

25
24
21

76

1450

18.5

3.5

200-400

200

140
200
260

53
50
44

53
50
44

68
75
71

1450

45

3.5

200-400A

200

131
187
243

46.6
44
38.3

46.6
44
38.3

67
74
70

1450

37

3.5

200-400B

200

122
174
226.5

40
38
33

40
38
33

73

1450

30

3.5

200-400C

200

112
160
208

34
32
28

34
32
28

71

1450

22

3.5

model

caliber

traffic

head

efficiency

speed

Motor power

Required cavitation allowance

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

200-200(I)

200

280
400
520

77.8
111.1
144

13.4
12.5
10.5

70
80
79

1450

22

4.0

200-200(I)A

200

250
358
465

69.4
90.4
129.2

10.7
10
8.5

68
73
77

1450

18.5

4.0

200-250(I)

200

280
400
520

77.8
111.1
144

22.2
20
14

75
80
72

1450

30

4.0

200-250(I)A

200

250
358
465

69.4
99.4
129.2

18
16
11.2

73
78
70

1450

22

4.0

200-250(I)B

200

226
322
419

62.8
89.4
116.4

14.4
13
7.3

70
75
67

1450

18.5

4.0

200-315(I)

200

280
400
520

77.8
111.4
144

36
32
26

73
80
75

1450

55

4.0

200-315(I)A

200

262
374
486

72.8
103.9
135

31.5
28
23

72
79
74

1450

45

4.0

200-315(I)B

200

242
346
450

67.3
96.1
125

27
24
19.5

78

1450

37

4.0

200-400(I)

200

280
400
520

77.8
111.4
144

54.5
50
39

75
81
77

1450

75

4.0

200-400(I)A

200

262
374
486

72.8
103.9
135

48
44
34

80

1450

75

4.0

200-400(I)B

200

242
346
450

67.2
96.1
125

41.4
38
29.6

78

1450

55

5.0

200-400(I)C

200

224
320
416

62.2
88.9
115.6

34.9
32
25

76

1450

45

5.0

model

caliber

traffic

head

efficiency

speed

Motor power

Required cavitation allowance

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

250-250

250

350
550
650

97.2
152.8
180.5

22
20
16

78
82
81

1450

45

5.0

250-250A

250

300
500
600

83.3
139
166.7

18.3
17
14

76
80
80

1450

37

5.0

250-235

250

300
500
600

83.3
139
166.7

14
12.5
11

73
78
70

1480

22

4.5

250-300

250

300
500
600

83.3
139
166.7

22
20
16

78

1480

37

4.5

250-315

250

350
550
650

97.2
152.8
180.5

34
32
28

76
80
79

1450

75

5.5

250-315A

250

300
500
600

83.3
139
166.7

29.5
28
24

74
78
77

1450

55

5.5

250-315B

250

260
450
520

72.2
125
144.4

25
24
20

70
74
72

1450

45

5.5

250-400

250

300
500
600

83.3
139
166.7

54.5
50
39

72

1480

90

4.5

model

caliber

traffic

head

efficiency

speed

Motor power

Required cavitation allowance

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

300-235

300

480
720
900

133.3
200
250

20
18
15.5

77
81
74

970

55

5.0

300-235A

300

438
607
821

121.7
182.5
228.1

16.5
15
13

75
79
72

970

45

5.0

300-235B

300

400
600
750

111.1
167.0
208.3

14
12.5
11

73
77
70

970

37

5.0

300-300

300

480
720
900

133.3
200
250

31
28
25

77
81
77

970

75

5.0

300-300A

300

444
666
833

123.3
185
231.4

26.5
24
21.5

76
80
76

970

75

5.0

300-300B

300

415
623
779

115.3
173.1
261.4

23
21
18.5

79

970

55

5.0

300-380

300

480
720
900

133.3
200
250

48
44
34

84

970

132

5.0

300-380A

300

444
666
833

123.3
185
231.4

41.4
38
30

80

970

110

5.0

300-380B

300

409
614
767

113.6
170.6
213.1

35
32
25

78

970

90

5.0

300-235(I)

300

718
1080
1345

199.4
300
373.6

44.6
40
34.6

82

1450

160

5.5

300-235(I)A

300

642
965
1203

178.3
268.1
334.2

35.7
32
27.7

80

1450

132

same series of products MORE>>
ISG型防爆立式管道泵|立式单级离心泵|立式单级变频管道离心泵
ISG explosion-proof vertical pipeline pump | vertical single-stage centrifugal pump | vertical single-stage variable frequency pipeline centrifugal pump
CDLF不锈钢管道泵|不锈钢管道离心泵
CDLF stainless steel pipeline pump | stainless steel pipeline centrifugal pump
IHG不锈钢耐腐蚀管道泵|不锈钢立式管道泵
IHG Stainless Steel Corrosion Resistant Pipeline Pump | Stainless Steel Vertical Pipeline Pump
QDLF不锈钢热水泵|立式多级热水泵|热水多级泵
QDLF stainless steel hot water pump | vertical multi-stage hot water pump | multi-stage hot water pump
GW防爆无堵塞管道泵
GW explosion-proof unobstructed pipeline pump

Related articles
Overview of Clean Water Pump 2007/8/14
Flash animation of the working principle of axial flow pipeline pump 2007/8/16
Technical characteristics and scope of use of pipeline pumps 2009/11/18
Working principle of pipeline pump 2012/1/26
Reasonable selection of vertical pipeline pumps, pipeline centrifugal pumps, and horizontal pipeline pumps 2012/1/26

Message box
Products of interest: *
Your name: *
Your unit: *
*
Detailed address:
Commonly used:
Any of your requests
Opinions or suggestions:
*
Verification code: *=Please enter the calculation result (fill in Arabic numerals), for example: Three plus four=7