Overview The LZDC series metal tube float flowmeter (also known as metal rotor flowmeter) has the characteristics of simple structure, reliable operation, wide applicability, high accuracy, and easy installation. Compared with glass rotor flow meters, this series of flow meters has the characteristics of high pressure resistance, high temperature resistance, strong sense of safety, and concise readings. And it can be applied to flow measurement of opaque and corrosive media. The instrument tube body and flange are made of stainless steel (ICr18Ni9Ti or OCr18Ni12Mo2Ti). The float is made of stainless steel, and the corrosion-resistant float and tube lining are made of polytetrafluoroethylene (PTFE). Measuring principle As shown in Figure 1, it consists of two parts: a flow sensor and a flow indicator. The float is vertically installed inside the conical measuring tube and can freely float up and down in the conical tube due to the action of the fluid. There is a high-performance embedded inside the float instrument data
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||

Dimensions: Flange Dimensions
Special installation dimensions can be requested from the manufacturer
Manufacturers can engage in non-standard design and production.
| Caliber mm | H | H1 | B | |||||
| J1 | J2 | J3 | J4 | J2 | J3 | J4 | J3 J4 | |
| 15 | 250 | 200 | 160 | 160 | 400 | 450 | 480 | 100 |
| 20 | 250 | 200 | 160 | 160 | 400 | 450 | 480 | 100 |
| 25 | 250 | 200 | 160 | 160 | 400 | 450 | 480 | 100 |
| 32 | 250 | 200 | 160 | 160 | 400 | 450 | 480 | 100 |
| 40 | 250 | 200 | 160 | 250 | 400 | 450 | 480 | 100 |
| 50 | 250 | 250 | 200 | 250 | 400 | 500 | 560 | 120 |
| 65 | 250 | 250 | 200 | 250 | 400 | 520 | 580 | 120 |
| 80 | 250 | 300 | 200 | 250 | 400 | 550 | 600 | 160 |
| 100 | 250 | 300 | 250 | 300 | 400 | 600 | 650 | 180 |
| 125 | 400 | 350 | 300 | 350 | 400 | 650 | 700 | 250 |
| 150 | 400 | 350 | 350 | 350 | 500 | 650 | 700 | 250 |
| 200 | 500 | 450 | 400 | 450 | 650 | 700 | - | 300 |
| 250 | 500 | 500 | 400 | 550 | 800 | 750 | - | 300 |
| caliber | Flange size (standard ANSI B 16.5 150 1bRF) | Caliber/Pressure | Flange size (standard DIN2501) | ||||||||||
| DN | D | k | d3 | f | n | d2 | DN/PN | D | k | d3 | f | n | d2 |
| 1/2 " | 88.9 | 60.5 | 35.1 | 1.6 | 4 | 15.7 | 15/4.0 | 95 | 65 | 45 | 1.5 | 4 | 14 |
| 3/4 " | 98.6 | 69.9 | 42.9 | 1.6 | 4 | 15.7 | 20/4.0 | 105 | 75 | 55 | 1.5 | 4 | 14 |
| 1 " | 108.0 | 79.2 | 50.8 | 1.6 | 4 | 15.7 | 25/4.0 | 115 | 85 | 65 | 1.5 | 4 | 14 |
| 1-1/4 " | 117.3 | 88.9 | 63.5 | 1.6 | 4 | 15.7 | 32/4.0 | 140 | 100 | 76 | 1.5 | 4 | 18 |
| 1-1/2 " | 127.0 | 98.6 | 73.2 | 1.6 | 4 | 15.7 | 40/4.0 | 150 | 110 | 86 | 1.5 | 4 | 18 |
| 2 inches | 152.4 | 120.7 | 91.9 | 1.6 | 4 | 19.1 | 50/4.0 | 165 | 125 | 100 | 2.0 | 4 | 18 |
| 2-1/2 " | 177.8 | 139.7 | 104.6 | 1.6 | 4 | 19.1 | 65/1.6 | 185 | 145 | 120 | 2.0 | 4 | 18 |
| 3 inches | 190.5 | 152.4 | 127.0 | 1.6 | 4 | 19.1 | 80/1.6 | 200 | 160 | 136 | 2.0 | 8 | 18 |
| 4 inches | 228.6 | 190.5 | 157.2 | 1.6 | 8 | 19.1 | 100/1.6 | 220 | 180 | 156 | 2.0 | 8 | 18 |
| 5 inches | 254.0 | 215.9 | 185.7 | 1.6 | 8 | 22.4 | 125/1.6 | 250 | 210 | 186 | 2.0 | 8 | 18 |
| 6 inches | 279.4 | 241.3 | 215.9 | 1.6 | 8 | 22.4 | 150/1.6 | 285 | 240 | 212 | 2.0 | 8 | 22 |
| 8 inches | 342.9 | 298.5 | 269.7 | 1.6 | 8 | 22.4 | 200/1.6 | 340 | 295 | 268 | 2.0 | 12 | 22 |
| 10 inches | 406.4 | 362.0 | 323.9 | 1.6 | 12 | 25.4 | 250/1.6 | 405 | 355 | 320 | 2.0 | 12 | 26 |


Indicator selection
M1 series indicator
The displacement of the magnetic float in the measuring tube is directly converted into flow rate through magnetic coupling
The value is indicated through a pointer and dial system.
Stainless steel stamping and surface polishing;
Mechanical pointer on-site flow indication, lightweight and aesthetically pleasing structure.
M2 series indicator
The displacement of the magnetic float in the measuring tube is directly converted into a flow rate value through magnetic coupling
It is indicated by the pointer and dial system, and converted into an electrical signal output at the same time.
◆ Digital integrated design of a multifunctional traffic board;
◆ Modular design, with optional combinations of local flow indication, remote transmission, accumulation, and alarm;
LCD on-site display of instantaneous flow, cumulative flow, and percentage flow;
◆ (4~20) mA two-wire system combined with HART protocol digital communication;
◆ Full function button operation for on-site instrument parameter setting;
Remote configuration using handheld or PC configuration software;
◆ Intrinsic safety+explosion-proof safety function;
◆ One or two threshold alarm switch outputs that can be adjusted across the entire range (optional);
◆ Can be directly applied to high-temperature environments (optional).




Note: Each indicator can be transmitted to any typeSensor combinations form flow meters of different forms and specifications.
Please refer to the selection table for specific selection.

LZDC series metal tube float flowmeter selection code
| 1. Series model: LZDC | |||||||||||||||||||
| 2. Path: Encoding | |||||||||||||||||||
| encoding | 015 | 025 | 040 | 050 | 080 | 100 | 125 | 150 | 200 | 250 | |||||||||
| DN | 15 | 25 | 40 | 50 | 80 | 100 | 125 | 150 | 200 | 250 | |||||||||
| 3. Installation form of measuring tube | |||||||||||||||||||
| J1 | Vertical installation form | ||||||||||||||||||
| J2 | Horizontal installation form | ||||||||||||||||||
| J3 | Bottom in and side out form | ||||||||||||||||||
| J4 | Side in, side out | ||||||||||||||||||
| J5 | Top in, bottom out | ||||||||||||||||||
| 4. Installation connection form | |||||||||||||||||||
| F | Flanges (conventional non GB or D I N, H G, A N S I, J I S are all optional) | ||||||||||||||||||
| L | thread | ||||||||||||||||||
| K | Clamp/Sanitary Type | ||||||||||||||||||
| 5. Material selection for measuring tubes | |||||||||||||||||||
| R1 | 304(1Cr18Ni9Ti) | ||||||||||||||||||
| R0 | 316(0Cr18Ni12Mo2Ti) | ||||||||||||||||||
| R00 | 316L(00Cr17Ni14Mo2) | ||||||||||||||||||
| RF | 304 with PTFE lining | ||||||||||||||||||
| other | Hastelloy, titanium alloy, aluminum alloy, zirconium alloy, copper alloy, etc | ||||||||||||||||||
| 6. Indicator type | |||||||||||||||||||
| M1 | On site indicator, stainless steel die-casting molding, surface polishing and wire drawing treatment, sanitary type | ||||||||||||||||||
| M2 | On site indicator, aluminum die-casting molding, surface coated with polyurethane epoxy paint | ||||||||||||||||||
| M3/ES4 | Remote output type with LCD, (4-20mA current) | ||||||||||||||||||
| M2/ES4 | Remote output type with LCD, (4-20mA current) | ||||||||||||||||||
| M2/HAPT | Remote output type with LCD, (4-20mA current, HART protocol digital communication) | ||||||||||||||||||
| M2/B | Powered by a 3.6V lithium battery, the LCD displays instantaneous and cumulative flow rates | ||||||||||||||||||
| 7. Explosion proof type | |||||||||||||||||||
| N | No explosion-proof requirements (omitted and not filled in) | ||||||||||||||||||
| EXi | intrinsically safe | ||||||||||||||||||
| EXd | Isolation explosion-proof type | ||||||||||||||||||
| 8. Measurement medium | |||||||||||||||||||
| L | liquid | ||||||||||||||||||
| G | gas | ||||||||||||||||||
| 9. Additional functions of measuring tube (optional) | |||||||||||||||||||
| T | Temperature protection jacket | ||||||||||||||||||
| 10. Additional indicator functions (optional) | |||||||||||||||||||
| KG22 | K1 lower limit alarm, K2 upper limit alarm | ||||||||||||||||||
| KG23 | KR1 lower limit alarm, KR2 upper limit alarm | ||||||||||||||||||
| KG24 | KE1 lower limit alarm, KE2 upper limit alarm | ||||||||||||||||||
| 11. High temperature type (optional) | |||||||||||||||||||
| H1 | Medium temperature: 120 ° C to 160 ° C | ||||||||||||||||||
| H2 | Medium temperature: 160 ° C to 250 ° C | ||||||||||||||||||
| H3 | Medium temperature: 250 ° C-400 ° C | ||||||||||||||||||
①②③④⑤⑥⑧
Give an example of LZDC/050/J1/F/R1/M2/L
① Metal tube float flowmeter ② Diameter DN50 ③ Vertical installation ④ Flange connection ⑤ 304 measuring tube ⑥ M2 local indicator ⑧ Liquid
| Specification Sheet
|