Welcome Customer !

Membership

Help

Jinhu Tianxiang Instrument Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Jinhu Tianxiang Instrument Co., Ltd

  • E-mail

    1119594485@qq.com

  • Phone

    15152325661

  • Address

    95-6 Tongtai Avenue, Jinhu County

Contact Now

Manufacturer of light diesel level gauge

NegotiableUpdate on 01/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Please refer to the following content for manufacturers of light diesel level gauges. The light diesel level gauge is a level gauge developed by our company to measure the height of liquid in storage tanks. This product is widely used in fields such as chemical and food factories, and has the characteristics of high measurement accuracy and long service life.

Product Details

Manufacturer of light diesel level gauge--Zhang Hao, Marketing Department of Jinhu Tianxiang Instrument Co., Ltd

Overview of Light Diesel Oil Level Gauge

Light diesel oil level gaugeIt is a product that the company introduces and absorbs similar foreign products, and improves its research and development production. The series of products can achieve high sealing, leak prevention, and safe and reliable measurement of liquid level under high temperature, high pressure, high viscosity, and strong corrosive conditions. The entire measurement process has no blind spots, eye-catching display, intuitive reading, and a large measurement range. Equipped with liquid level alarm and control switch, it can realize upper and lower limit alarm and control of liquid level or boundary. Paired with LB type liquid level transmitter, it can convert liquid level and boundary signals into two-wire 4-20mADC standard signals, realizing remote detection, indication, recording, and control. The series of products are widely used for liquid level measurement and control in various industries such as power, petroleum, chemical, metallurgy, environmental protection, shipbuilding, construction, and food production processes.

Light diesel oil level gaugeProduct principle:

It is based on the principle of connectivity and magnetic coupling to achieve real-time measurement of liquid level. When the liquid level in the tested container rises or falls, the magnetic float inside the float also rises or falls accordingly. The magnetic steel inside the float drives the magnetic flap outside the float to flip 180 ° through magnetic coupling. The flap is painted with different colors (usually red and white) on both sides to indicate the position of the liquid level. Generally, when the liquid level in the container rises, the flap changes from white to red, and when the liquid level in the container drops, the flap changes from red to white. The red white boundary of the indicator is the actual height of the liquid level in the container, thus achieving accurate measurement of the liquid level.

It is widely used to detect the liquid level of various towers, tanks, tanks, spherical containers, boilers, and other equipment. It can measure the liquid level under high sealing, leak proof, high-pressure, high-temperature, and corrosive conditions, and has the characteristics of safety and reliability. It makes up for the shortcomings of unclear indication and easy breakage of glass plate (tube) level gauges, and is not affected by high and low temperature fluctuations, without the need for multiple sets of level gauge combinations. The entire measurement process has no blind spots, with clear display, intuitive readings, and a large measurement range. The on-site instructions are more effective against high temperature, high pressure, high viscosity, toxic, harmful, and highly corrosive media as they do not come into direct contact with liquid media. Therefore, it has higher reliability, safety, reliability, and practicality than traditional glass tube and plate level gauges. The significant feature of the side mounted magnetic flip column level gauge is that the liquid medium is isolated from the indicator, making it very safe, reliable, and durable in any situation. Moreover, various models of level gauges are equipped with level alarms and control switches, which can achieve upper and lower limit level alarms, control, or interlocking of the liquid level or interface.

Light diesel oillevel gaugeSealing surface type

<strong><strong>磁翻板液位计</strong></strong>密封面型式

Technical parameters of light diesel level gauge

Measurement range LD200-15000mL1: It depends on the specific gravity of the medium and the material of the float, as shown in the table below

specific gravity of medium L1(mm)
Rust proof aluminum float (LF)2)And LF2Float wrapped in fluoroplastic stainless steel浮子 (1Cr18ni9Ti)
0.45 463
0.55 286
0.65 210
0.75 166
0.85 140 340
0.95 120 260
≤1.0 113 220

D: ¢ 52~¢ 83: ¢ 115~¢ 200 (depending on pressure)

Measurement accuracy: ± 10mm Medium temperature: ≤ 80 ℃, can also be made into ≤ 480 ℃ Medium specific gravity: ≥ 0.4 Medium viscosity: ≤ 0.02Pa · S Connection flange:

DN20 PN(MPa)
0.6~2.5 4.0~16.0
Standard Number HG20593-97 HG20595-97
Dg15 Pg(Kgf/cm2
220 320
Standard Number H12-0-2 H12-0-3

Note: HG20595-97 Our factorylevel gaugeChoose FM surfacelevel gaugeInstallation byenvironmentinfluence. If the spatial position L1 is less than 300, it should be clearly stated when placing an order.

Manufacturer of light diesel level gaugeClassification and Applicable Scenarios:

1. Ordinary type: suitable for low, medium, and high pressure applications without special anti-corrosion requirements.
2. Vacuum type: suitable for ultra-low, ultra-high temperature, low, medium, high pressure, and no special anti-corrosion requirements.
3. Frost proof type: suitable for low temperature, low, medium, high pressure, and occasions without special anti-corrosion requirements.
4. Underground type: suitable for underground or top perforated storage tanks, where the medium does not move much.
5. Jacket type: suitable for situations that require insulation or cooling, low, medium, and high pressure, and no special anti-corrosion requirements.
6. Inner lining type: PTFE or other lining, suitable for low, medium, and high pressure applications with special anti-corrosion requirements.
7. Anti corrosion type: made of PP or PVC material, suitable for corrosion resistant applications at room temperature and atmospheric pressure.

Selection of Light Diesel Oil Level Gaugeparameter

Installation type

content

side-mounted

Top mounted

Installation spacing
(Measurement range)

500,800,1100,1400,1700,
2000,2500,3000,3500,4000,
4500,5000,5500,6000mm

500,800,1100,1400,1700,
2000,2500,3000mm

work pressure

0.6,1.6,2.5,4.0MPa

0.6,1.6,2.5MPa

medium density

≥ 0.5g/cm 3

≥ 0.76g/cm 3

flange connection

stainless steel

Flange 20-40 (D N 20 P N 4.0)
(GB9119-88)

Flange 200-25 (D N 200 P N 2.5)
(GB9119-88)

ABS

Flange 20-10 (D N 20 P N 1.0) (GB9119-88)

Flange 200-6 (D N 200 P N 0.6)
(GB9119-88)

main material

ABS (working pressure 0.6MPa) 1Cr18Ni9T

medium temperature

-40 ℃ ~100 ℃ (ABS: -40 ℃ ~80 ℃ )

ambient temperature

-40 ℃ ~+70 ℃

indication error

± 10mm

medium viscosity

≤ 1st(10 - 4 m/s)

Upper and lower limit switches
output

1. Control sensitivity: 10mm
2. Output contact capacity: AC220V 2A
3. Contact life: 5 × 10 4

Continuous display of electric remote transmission

1. Accuracy: ± 1.5%
2. Output load: 750
3. Output signal: 0~10mA output, 220VAC power supply
4~20mA output, 24VDC two-wire system
4. Explosion proof feature ia Ⅱ CT4 intrinsic safety type