Welcome Customer !

Membership

Help

Jinan Runzhi Technology Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Jinan Runzhi Technology Co., Ltd

  • E-mail

    jnrise@163.com

  • Phone

    15588824207

  • Address

    602, Building 15, Qilu Cultural and Creative Base, No. 101 Shunfeng Road, High tech Zone, Jinan City, Shandong Province

Contact Now

Dry laser particle size analyzer

NegotiableUpdate on 02/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Rise-2012 dry laser particle size analyzer measurement range: 0.1-600 microns accuracy error:; amp; #177; 1% (standard substance D50) repeatability deviation:< amp; #177; 1% (standard substance D50) electrical requirements: AC 220 amp; #177; 10V, 50Hz, 200W Appearance size: 1000 amp; #215; 330 amp; #215; 320mm weight: 38KG
Product Details

Rise-2012 dry laser particle size analyzerTechnical Indicators:

1. Measurement range: 0.1-600 micrometers

2. Accuracy error:<± 1% (standard substance D50)

3. Repeatability deviation:<± 1% (standard substance D50)

4. Electrical requirements: AC 220 ± 10V, 50Hz, 200W

5. Exterior dimensions: 950 × 330 × 300mm

6. Weight: 40KG

Rise-2012 dry laser particle size analyzerWorking Principle:

The Rise-2012 dry laser particle size analyzer adopts the full range Mie scattering theory, fully considering the optical properties such as refractive index of the measured particles and dispersed media. Based on the changes in scattering intensity of particles of different sizes at various angles, the particle size distribution data of the particle group is inverted.

The data calculation of particle testing is generally divided into two methods: unconstrained fitting inversion and constrained fitting inversion. Constrained fitting inversion assumes that the particle population follows a certain distribution pattern before calculation, and then uses this pattern to invert the particle size distribution. This type of operation is relatively simple, but due to the inevitable deviation between the assumptions made in advance and the actual situation, the test data obtained by constrained fitting cannot truly reflect the actual particle size distribution of the particle group.

Unconstrained fitting inversion means that no assumptions are made about the particle population before testing, and the particle size distribution of the particle population is accurately calculated directly through light intensity. This calculation is based on reasonable detector design and granularity grading, which puts high demands on the equipment itself. The Rise-2012 dry laser particle size analyzer adopts a non-uniform cross three-dimensional fan-shaped matrix detector array and reasonable particle size grading, which can accurately measure the particle size distribution of particle groups.

Rise-2012 typeTechnical features:

Testing a stable foundationOnly when the system can provide stable optical signals can the stability of test data be fully guaranteed. The Rise-2012 dry laser particle size analyzer uses a He Ne gas laser light source with a wavelength of 0.6328 microns, short wavelength, narrow linewidth, good stability, and a service life of over 25000 hours, which can provide stable laser source signals for the system.

Guarantee of Reliable DataTo ensure the reliability of test data, the first step is to design the signal detection system reasonably. The quality of the dispersion effect of the tested sample is another decisive factor in obtaining the true results.

detectorThe photoelectric detection system design is highly sensitive, with one main detector and multiple auxiliary detectors arranged in a non-uniform cross three-dimensional fan-shaped matrix. The maximum detection angle reaches 90 degrees, fully ensuring the comprehensiveness of signal detection.

optical pathAdopting a range design, converging light path * reduces the Fourier lens group, making the measurement range wider, resolution higher, and light path adjustable.

Powerful analysis software

The PADMAS Particle Diameter Measure&Analysis System has powerful functions, and test data can be processed through averaging, statistics, comparison, and pattern conversion. It has various formats such as differential distribution, cumulative distribution, standard grading, R-R distribution, custom grading, target grading, and quantity distribution. The default grading is 130 levels within the range of 0.02~2000 microns, and the grading can be customized within the range of 1~130 levels. The test report includes particle size distribution graphs and particle size data charts, as well as characteristic parameters such as D10, D50, D90, average particle size, and specific surface area. There are four custom parameters that can be entered as needed, and weight specific surface area and volume specific surface area can be interchanged. Granular data can be saved to EXCEL. Supports printing test reports in both Chinese and English formats. The header and footer can be modified as needed, and there is a print preview function. It can save granularity distribution graphics and granularity data charts in image or PDF format for interactive use with WORD. Other processing functions can be added according to user needs. Easy to operate: Standard, quantitative, and simple operations can be mastered proficiently in a short period of time, and the testing data process can be completed within 1 minute.

Strong visibilityThe testing software has a user-friendly interface, clear and visible testing process, instant refresh, strong visibility, and can observe the operation status of the instrument and the fluctuation of test data at any time, analyzing the authenticity and reliability of the measured data. The operation keys are all located on the intelligent touch panel, providing standard, quantitative, and simple operations, effectively reducing testing time and lowering the requirements for operators.

Equipment maintenanceComprehensive technical training, detailed user manuals, and online software assistance enable operators to operate accurately, solve problems, and troubleshoot.

Based on the physical and chemical properties of the sample, such as density, anisotropy, brittleness, magnetism, toxicity, flowability, agglomeration, solubility, and physical and chemical reactions, we have developed a scientific, systematic, and complete dispersion testing plan, which will be provided to users along with the instrument. We not only sell instruments, but also provide decentralized testing solutions.

Rise-2012 Hardware Introduction:

Hardware design *, produced according to Q/01RZ01-2004 standard, with professional manufacturing of components, stable and reliable performance, and no vulnerable parts.

Dispersion method

The Rise-2012 dry laser particle size analyzer is a high-performance instrument. The system consists of a laser particle size analyzer, an automatic dry dispersion system, an oil-free air compressor, an efficient condenser, and other components. In the dry state, the sample is uniformly transported to the high-pressure airflow through an automatic dry powder sampler, and continuously sprayed at high speed into the disperser under the drive of the high-pressure airflow. At the outlet of the disperser, the sample has been fully dispersed, and after passing through the laser beam, it enters the collector. At the same time, the computer immediately displays the particle size distribution information.

1. Dry dispersionNo dispersants or solvents are required. The dispersion principle is shown in the following figure

Friction induced shear force generated by the friction of the dispersing tube, collision between particles, and collision between particles and the dispersing tube wall

2. Adopting an oil-free air compressor, coupled with an efficient condenser, to ensure the production of pure compressed air;

3. Instantaneous dispersion and measurement, fast testing accuracy, high analysis efficiency, completed within one minute from sample injection to result output;