Welcome Customer !

Membership

Help

Wuhan Chuangyi Electrical Equipment Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Wuhan Chuangyi Electrical Equipment Co., Ltd

  • E-mail

    2708684618@qq.com

  • Phone

    13638682503

  • Address

    No. 9-2-203, Xinhua Jiayuan Second District, Xinhua Xia Road, Jianghan District

Contact Now

CYKH-12 Intelligent Battery Cell Activation Instrument

NegotiableUpdate on 01/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Product Overview: CYKH-12 Intelligent Battery Cell Activation Instrument can perform activation tests on single cells with three different voltage levels of 2V, 6V, and 12V. It is a portable product specifically designed for handling outdated batteries during daily maintenance. It has three independent usage modes: battery discharge mode, battery charging mode, and battery activation mode

Product Details

Product Overview

The CYKH-12 intelligent battery cell activator can perform activation tests on single cells with three different voltage levels of 2V, 6V, and 12V. It is a portable product specifically designed for handling outdated batteries during daily maintenance. It has three independent usage modes: battery discharge mode, battery charging mode, and battery activation mode. According to the actual situation of different outdated batteries, capacity tests can be conducted on outdated batteries, such as low-voltage constant current charging, or setting multiple cycle periods to cycle and discharge the battery with the minimum capacity multiple times, in order to activate the active substances that cause the failure of the battery plates and improve the capacity of outdated batteries. Simultaneously equipped with PC application software, the collected data is uploaded to the computer for various analyses.

Product Application

The activator is a battery repair and maintenance equipment. After selecting the fallen batteries through testing, there is another important thing we need to do, which is to restore the capacity of as many outdated batteries as possible. That's why the stage of the activator was established. Generally, battery failures in communication units are mostly caused by the crystallization of the electrode plate, resulting in a decrease in capacity (chemical failures are more common, while physical failures are rare, so the activator still has a certain maintenance function). The activator is used to charge and discharge the battery with high current to melt the crystal and activate the chemical substances inside. Generally, after activation, the capacity can be restored to over 90% of its rated capacity. However, it is worth noting that not all outdated batteries can be activated. The activation device can only adapt to some of the outdated reasons in chemical faults. As for physical faults, the activation device cannot be repaired, such as plate short circuits.

Product Features


  • Measure comprehensively and accurately display the operating results and waveforms of battery voltage, current, charging (discharging), and activation during maintenance.
  • Online activation, which can activate individual batteries in float charging state.
  • Powerful function, capable of charging (discharging) the battery separately and continuously charging (discharging) N times (no more than 99 times).
  • Adopting electronic load, forced air cooling, safe and reliable, with a long service life.
  • Chinese and English menu operation, easy to learn and use.
  • Powerful random software can analyze the long-term operating status of battery charging (discharging) and activation.
  • Use a USB flash drive to store or exchange data, and update programs through the USB flash drive.
  • The instrument program can be customized and updated according to user needs.


Product features


  • Charging and discharging, activation, and curve indication functions
  • The intelligent battery activator has three main functions: charging, discharging, activation, and corresponding curve indication. The curve can be displayed after each operation. The charging (discharging) curve is displayed on the right side of the screen, and the charging (discharging) and activation parameters are displayed on the left side, including: voltage (current) prompt, battery number, battery internal resistance, discharging (charging) current, cut-off voltage, horizontal time scale, vertical voltage (current) scale, and total discharge time.
  • Curve playback function
  • When performing charging (discharging) and activation operations, pressing the 【 Return 】 key can interrupt the charging (discharging) and activation process at any time. Only after effective charging (discharging) or activation can various data collected during the charging (discharging) process be saved. When saving data, select the sequence number of the existing playback curve to obtain the curve that needs to be played back. Press the left and right keys to switch between different numbers to obtain different playback curve waveforms.
  • Data management function
  • Allow users to manage the measured and controlled data of the battery, including data upload and curve playback.
  • System upgrade
  • Allow users to upgrade and update the host operating system online, easily and quickly through USB flash drives.


Product Parameters

model
Cykh- 12
battery voltage
2V
6V
12V
discharge current
0~100A
0~30A
0~30A
charging current
100A
30A
30A
Upper limit voltage
2.4V
7.2V
15.0V
Lower limit voltage
1.7V
4.8V
10.2V
display mode
Chinese English LCD
current accuracy
1% ±0.5A
voltage accuracy
0.25%
communication interface
USB
Chassis dimensions
400×176×272mm
weight
10 kg
Operating Temperature
0~45degc
working power supply
AC 220V±10%
remark
The listed technical indicators are standard configurations