Welcome Customer !

Membership

Help

Zhejiang Yangtze River Pump Industry Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products
Product Categories

Zhejiang Yangtze River Pump Industry Co., Ltd

  • E-mail

    wt50120@126.com

  • Phone

    13868628633

  • Address

    Dongou Industrial Zone, Oubei Town, Yongjia County, Zhejiang Province

Contact Now

CQ explosion-proof stainless steel magnetic pump for acid pumping

NegotiableUpdate on 03/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
CQ type stainless steel magnetic pump (referred to as magnetic pump) is a new product that applies the working principle of permanent magnet coupling to centrifugal pumps. It is designed reasonably, processed *, and has the characteristics of full sealing, no leakage, and corrosion resistance. Its performance reaches the * level of similar foreign products.
Product Details

1Stainless steel magnetic pumpProduct Overview:
CQ type stainless steel magnetic pump (referred to as magnetic pump) is a new product that applies the working principle of permanent magnet coupling to centrifugal pumps. It is designed reasonably, processed *, and has the characteristics of full sealing, no leakage, and corrosion resistance. Its performance reaches the * level of similar foreign products.
IIStainless steel magnetic pumpKey Features:
Magnetic pumps replace dynamic seals with static seals, keeping the overcurrent components of the pump in a sealed state, solving the problems of running, emitting, and dripping that cannot be avoided by mechanical seals of other pumps. Magnetic pumps use corrosion-resistant and high-strength engineering plastics, steel jade ceramics, and stainless steel as manufacturing materials, so they have good corrosion resistance and can protect the transported medium from pollution.
IIIStainless steel magnetic pumpProduct Usage
Magnetic pump has a compact structure, beautiful appearance, small volume, low noise, reliable operation, and easy use and maintenance. It can be widely used in chemical, pharmaceutical, petroleum, electroplating, food, national defense, scientific research institutions, metallurgy, dyes and other units to pump acid, alkali solution, rare and valuable oil liquids, venom, volatile liquids, as well as supporting circulating water equipment and filter machines. Especially for the pumping of liquids that are prone to leakage, combustion, and explosion. This pump is a more ideal equipment for explosion-proof motors.

5Stainless steel magnetic pumpInstallation and Usage

1. The magnetic pump should be installed horizontally and not vertically. The plastic pump body should not bear the weight of the pipeline. For special requirements for vertical installation, the motor must face upwards.

When the suction liquid level is higher than the pump axis line, open the suction pipeline valve before starting. If the suction liquid level is lower than the pump axis line, the pipeline needs to be equipped with a bottom valve.

3. Before using the pump, it should be checked that the motor fan blades rotate flexibly, without jamming or abnormal sound, and all fasteners should be tightened.

4. Check if the motor rotation direction matches the magnetic pump direction mark *.

5. After the motor starts, slowly open the discharge valve and adjust it to the desired opening after the pump enters normal operation.

Before the pump stops working, the discharge valve should be closed first, and then the suction pipe valve should be closed.

6、 Precautions for use

1. As the cooling and lubrication of the magnetic pump bearings rely on the medium being transported, it is prohibited to operate them without load, and at the same time, it is necessary to avoid idle operation caused by restarting after a power outage during operation.

If the conveyed medium contains solid particles, a filter screen should be added to the pump inlet. If it contains ferromagnetic particles A magnetic filter needs to be added.

3. The ambient temperature of the pump during use should be less than 40 ℃, and the temperature rise of the motor should not exceed 75 ℃.

4. The conveyed medium and its temperature should be within the allowable range of the pump material. The operating temperature of engineering plastic pumps is less than 60 ℃, the operating temperature of metal pumps is less than 100 ℃, the auxiliary suction pressure is not greater than 0.2MPa, the maximum working pressure is 1.6MPa, the density is not greater than 1600 ^ kg/m3, and the particle size is not greater than 30 X 10-6 ㎡/S of liquid without hard particles and fibers.

5. For media that are prone to precipitation and crystallization during transportation, they should be cleaned promptly after use and the accumulated liquid in the pump should be drained.

After 500 hours of operation of the magnetic pump, the wear and inertia of the bearings and end face moving rings should be inspected. If the gap between the bearings and the shaft sleeve is greater than 0.5-1mm, the axial displacement of the impeller should be 1.5 degrees? When 2mm, the bearing and axial moving ring should be replaced.

CQ typeStructural diagram of stainless steel magnetic pump

        

1

pump casing

2

static ring

3

power and environment monitoring system

4

impeller

5

sealing ring

6

partition

7

isolation sleeve

8

External magnetic steel assembly

9

Internal magnetic steel assembly

10

pump shaft

11

bushing

12

Connecting frame

13

motor

14

CQ typeStainless steel magnetic pump installation size table:

model

a

b

c

d

e

f

g

h

j

a

k

m

n

Machine base screw hole

p

p1

q

q1

φ

φ

Pipe connection

08cq-2

63

48

45

55

38

200

105

45

15

84

80

24

16

φ6

-

-

-

-

-

-

10cq-3

63

48

45

55

38

200

105

45

15

84

80

24

16

φ6

-

-

-

-

-

-

14cq-5

90

71

95

107

53

270

120

56

16

130

130

37

18

φ7

-

-

-

-

-

-

16cq-8

90

70

80

125

55

320

160

65

18

115

140

40

22

φ11

-

-

-

-

-

-

20cq-12

100

80

105

130

59.5

340

160

73

18

130

160

65

26

φ12

-

-

-

-

-

-

25cq-15

125

100

140

189.5

67.5

460

205

90

-

160

240

71.5

-

φ12

75

65

100

90

120

10

Flange connection

32cq-15

125

100

140

189.5

67.5

460

205

90

-

160

240

71.5

-

φ12

90

75

120

100

12

10

32cq-25

125

100

140

189.5

67.5

460

230

90

-

160

260

85

-

φ12

90

75

120

100

12

10

40cq-20

140

120

155

235

75

545

220

100

-

180

290

78.5

-

φ12

100

90

130

120

14

14

40cq-32

190

140

190

271

80

620

260

112

-

245

336

91

-

φ12

100

90

130

120

14

14

50cq-25

190

140

190

271

80

620

260

112

-

245

336

91

-

φ12

110

100

140

130

14

14

50cq-40

190

140

190

271

80

620

260

112

-

245

336

91

-

φ12

110

100

140

130

14

14

65cq-25

216

140

200

305

90

695

300

132

-

280

350

91

-

φ12

130

110

160

140

14

14

65cq-35

216

140

200

360

76

720

292

120

-

280

350

90

-

φ12

130

110

160

140

14

14

80cq-35

254

210

-

-

-

890

160

-

-

-

-

-

φ12

-

-

-

-

14

14

80cq-50

254

210

-

-

-

890

160

-

-

-

-

-

φ12

-

-

-

-

14

14

Installation and use:

1. Magnetic pumps should be installed horizontally and not vertically. The plastic pump body should not bear the weight of the pipeline. For special requirements for vertical installation, the motor must face upwards.

2. When the suction liquid level is higher than the pump axis line, open the suction pipeline valve before starting. If the suction liquid level is lower than the pump axis line, the pipeline needs to be equipped with a bottom valve.

3. Before using the pump, it should be checked that the motor fan blades rotate flexibly, without jamming or abnormal noise, and all fasteners should be tightened. 4. Check if the motor rotation direction matches the magnetic pump direction mark *.

5. After the motor starts, slowly open the discharge valve and adjust it to the desired opening after the pump enters normal operation.

6. Before the pump stops working, the discharge valve should be closed first, and then the suction pipe valve should be closed.

CQ typePrecautions for using stainless steel magnetic pump

1. Due to the fact that the cooling and lubrication of magnetic pump bearings rely on the medium being transported, idle running is prohibited, while avoiding spatiotemporal load running caused by restarting after a power outage during operation.

2. If the conveyed medium contains solid particles, a filter screen should be added to the pump inlet; if it contains ferromagnetic particles, a magnetic filter should be added.

3. The ambient temperature of the pump during use should be less than 40 ℃, and the temperature rise of the motor should not exceed 75 ℃.

4. The conveyed medium and its temperature should be within the allowable range of the pump material (see attached table for details). The operating temperature of engineering plastic pumps is less than 60 ℃, the operating temperature of metal pumps is less than 100 ℃, the conveying suction pressure is not greater than 0.2mpa, the maximum working pressure is 1.6mpa, the density is not greater than 1600kg/m3, the particle size is not greater than 30 × 10-6m2/s, and the liquid does not contain hard particles and fibers.

5. For media that are prone to precipitation and crystallization during transportation, they should be cleaned promptly after use to drain the accumulated liquid in the pump. 6. After 500 hours of operation of the magnetic pump, the wear of the bearings and end face dynamic rings should be disassembled and inspected. If the gap between the bearings and the shaft sleeve is greater than 0.5-1mm, and the axial displacement of the impeller is 1.5-2mm, the bearings and axial dynamic rings should be replaced.

CQ typePerformance parameter table of stainless steel magnetic pump

type number

caliber

traffic(m3/h)

head(m)

Motor power(kW)

electricity press

(V)

material

Import(mm)

Export(mm)

14CQ-5

14

10

1.2

5

0.12

220/380

no

rust

steel

16CQ-8

16

12

1.8

8

0.18

220/380

20CQ-12

20

12

3

12

0.37

220/380

25CQ-15

25

20

5.4

15

1.1

380

32CQ-15

32

25

6.5

15

1.1

380

32CQ-25

32

25

4.8

25

1.1

380

40CQ-20

40

32

10

20

2.2

380

40CQ-32

40

32

11.5

32

4

380

50CQ-25

50

40

14.4

25

4

380

50CQ-32

50

40

13.2

32

4

380

50CQ-50

50

32

7.8

50

5.5

380

65CQ-25

65

50

16.8

25

5.5

380

65CQ-32

65

50

25

32

7.5

380

80CQ-32

80

65

50

32

11

380

50CQ-50

80

65

50

50

15

380

100CQ-32

100

80

60

32

15

380

100CQ-50

100

80

60

50

18.5

380

note:in the table16CQ-8---100CQ-50Can be equipped with explosion-proof motors

CQ typeThe significance of stainless steel magnetic pump model

             

CQ typeCharacteristic Curve of Stainless Steel Magnetic Pump

Fault and Troubleshooting

failure mode

root cause

exclusion method

The pump is not producing water

Reverse rotation of water pump

Leakage of water pipeline

Insufficient water storage in the pump chamber

The voltage is too high, causing the coupling to slip during startup

The suction distance is too high

Change the motor wiring

Social isolation leakage

Increase storage capacity

Adjust the positive voltage

Lower the installation position of the pump

insufficient traffic

The suction pipe diameter is too small

Impeller channel blockage

Head too high

The speed is too low

Replace the inlet pipe

Clean the impeller

Turn up the outlet valve

Rated speed of Huixia

Low head

Excessive traffic

The speed is too low

Turn down the outlet valve

Restore rated speed

矂音太大

Severe wear of the shaft

Severe wear of the shaft sleeve

Drive the magnetic steel cup to contact the isolation sleeve

Replace the pump shaft

Replace the shaft sleeve

Dismantle the pump head and reassemble it

Leakage of liquid

Type 0 sealing ring damaged

Replace the 0-type sealing ring

Corrosion resistance of materials (for reference)

medium name

concentration

%

polypropylene

concentration

%

ABC

25℃

50℃

20℃

60℃

Sulfuric acid

60

×

Nitric acid

25

O

Hydrochloric acid

<36

Fluorofluoric acid

35

×

acetic acid

<80

O

sodium hydroxide

100

potassium dichromate

25

Bromine water

O

×

ethanol

acetone

×

O

*

O

O

×

Freon 22

O

O

Bleach solution

CL13%

O

O

Electroplating solution

O

×

Photographic liquid

medium name

concentration

stainless steel

concentration

ceramics

%

25℃

50℃

%

25℃

80℃

sulfuric acid

<5

X

V

V

nitric acid

7070

V

V

V

hydrochloric acid

X

V

V

Fluorofluoric acid

X

0~100

X

acetic acid

<20

V

V

sodium hydroxide

70

0

X

potassium dichromate

40~60

V

V

10~20

V

V

Bromine water

0

V

V

ethanol

V

V

V

acetone

V

V

V

*

50

V

V

V

V

Freon 22

V

V

V

Bleach solution

C112%

X

V

V

Electroplating solution

V

V

Photographic liquid

V

V

V

Symbol Description: V - Excellent V - good, 0- usable But the corrosion is obvious X - severe corrosion, not applicable.

same series of products MORE>>
MT-HTP型不锈钢高温磁力泵
MT-HTP stainless steel high-temperature magnetic pump
CQ型磁力驱动泵
CQ type magnetic drive pump
ZCQ型自吸式磁力泵
ZCQ type self-priming magnetic pump
CQB-F型氟塑料磁力泵|防爆氟塑料合金磁力泵
CQB-F Fluoroplastic Magnetic Pump | Explosion proof Fluoroplastic Alloy Magnetic Pump
CQB-G型高温保温磁力泵
CQB-G type high-temperature insulation magnetic pump
Related articles
Working principle of magnetic pump 2007/8/16
The correct selection method for magnetic pumps 2007/8/27
Historical development characteristics of magnetic pumps 2009/11/14
Precautions for Magnetic Pump 2012/2/3
Installation and use of magnetic pump 2012/2/3

Message box
Products of interest: *
Your name: *
Your unit: *
*
Detailed address:
Commonly used:
Any of your requests
Opinions or suggestions:
*
Verification code: *=Please enter the calculation result (fill in Arabic numerals), for example: Three plus four=7

Related Products

  • CQ explosion-proof stainless steel magnetic pump for pumping acid pump, alkali solution pump, rare and valuable oil liquid pump, venom pump, volatile liquid pump
  • CQB high and low temperature magnetic centrifugal explosion-proof pump, corrosion-resistant explosion-proof pump, high flow explosion-proof pump
  • UHB-ZK100-60-30 corrosion-resistant and frosted slurry pump, high flow chemical pump, acid resistant pump
  • Sewage pump manufacturer 125UHB-ZK-140-28 corrosion-resistant and frosted slurry pump chemical sewage pump
  • Corrosion resistant and wear-resistant mortar pump, mud pump, fluorine lined pump UHB-ZK series
  • Manufacturer supplied UHB-ZK absorption tower circulation pump, gypsum discharge pump, lime slurry pump, desulfurization pump
  • Manufacturer supplied UHB-ZK mortar pump, corrosion-resistant, wear-resistant, resistant to dilute acid and alkali, strong corrosive, high-temperature resistant, acetic acid slurry pump
  • UHB-ZK250/800-32 high flow desulfurization pump, sewage pump | corrosion-resistant mortar pump
  • Corrosion resistant pump 200UHB-ZK-168-20 Corrosion resistant and frosted slurry pump Chemical pump lined with fluoroplastic pump
  • 65UHB-ZK-5-11 horizontal corrosion-resistant and wear-resistant mortar pump, acid and alkali resistant chemical anti-corrosion pump, desulfurization circulating pump
  • Corrosion resistant mud pump, sewage pump, 50UHB-ZK-25-28 corrosion resistant and wear-resistant mortar pump, chemical pump
  • 40UHB-ZK-10-30 wear-resistant pump lined with fluorine wear-resistant mortar pump wear-resistant chemical pump horizontal mortar pump
  • 80UHB-ZK-45-50 mortar pump, polymer corrosion-resistant centrifugal pump, desulfurization pump, sewage pump
  • 65UHB-ZK-30-32 corrosion-resistant and frosted slurry pump, polymer mortar pump, sewage pump, fluorine lined pump
  • Corrosion resistant pump 50UHB-ZK-20-20 Corrosion resistant and frosted slurry pump Chemical pump lined with fluoroplastic pump
  • UHB-ZK Fluoroplastic Alloy Mortar Pump 65UHB-ZK-10-50A Slurry Circulating Pump
  • UHB-ZK type corrosion-resistant and frosted slurry pump, organic solvent particle conveying pump, wear-resistant pump
  • Corrosion resistant mud pump, sewage pump, 125UHB-ZK-120-32 corrosion resistant and wear-resistant mortar pump, chemical pump
  • *350UHB-ZK-1800-25 corrosion-resistant slurry pump reinforced alloy high-temperature resistant mortar pump
  • UHB-ZK type corrosion-resistant and wear-resistant pump 65UHB-ZK-A-30-80 high-pressure corrosion-resistant and wear-resistant pump
  • UHB-ZK corrosion-resistant and frosted slurry pump, slurry pump, filter press pump, sewage pump*
  • 100UHB-ZK-70-45 horizontal acid, alkali, high temperature sewage slurry pump with long service life, corrosion and wear resistance
  • UHB horizontal fluorine lined chemical centrifugal pump, acid alkali resistant chemical desulfurization pump, high-temperature sewage pump
  • UHB acid pump, alkali pump, filter press pump, corrosion-resistant pump, chemical pump, sewage pump
  • CQB80-65-160F desulfurization pump | filter press pump | electrophoresis pump | acid washing pump | corrosion-resistant and wear-resistant pump
  • CQB80-65-160F corrosion-resistant pump | fluorine pump | alkali pump | acid pump | fluorine lined pump | desulfurization pump | filter press pump
  • CQB80-65-160F Fluoroplastic Magnetic Pump Stainless Steel Magnetic Pump High Temperature Magnetic Pump Magnetic Drive Pump
  • Manufacturer * Magnetic Conveyor Pump Corrosion Resistant Horizontal Pump CQM40-25-200
  • High temperature magnetic pump manufacturer leak free pump CQB40-25-200G stainless steel pump
  • CQB-G High Temperature Magnetic Pump (Water Cooled) * Available in stock, acid and alkali resistant magnetic pump can be customized
  • CQ type magnetic drive pump circulating magnetic pump direct sales horizontal engineering plastic magnetic pump stainless steel magnetic pump
  • CQB G high-temperature magnetic drive centrifugal pump air-cooled magnetic pump magnetic drive centrifugal pump
  • CQ cooling circulating water pump, corrosion-resistant stainless steel magnetic pump, explosion-proof high-temperature chemical magnetic pump
  • CQG65-100 Pipeline Stainless Steel Magnetic Pump Leak Free, Acid and Alkali Corrosion Resistant Chemical Pump
  • Quality Assurance Fluoroplastic Magnetic Hydrofluoric Acid Corrosion Resistant Drive Pump CQB40-25-120 Hydrofluoric Acid
  • Fluoroplastic magnetic pump IMD80-65-120F chemical pump acid alkali resistant anti-corrosion pump
  • Fluoroplastic Magnetic Pump Horizontal Fluoroplastic Magnetic Pump CQBF Magnetic Pump CQB Fluoroplastic
  • Fluoroplastic pump, Fluoroplastic magnetic pump, Fluoroplastic centrifugal pump, Metal magnetic pump
  • Fluorine lined centrifugal pump, fluorine lined magnetic pump, stainless steel self-priming pump, fluoroplastic magnetic self-priming pump
  • Fluoroplastic magnetic pump, acid resistant magnetic pump, corrosion-resistant magnetic pump, self-priming magnetic pump, wear-resistant and corrosion-resistant mortar pump, fluorine lined centrifugal pump