Anhydrous heating salt spray testing machineIntroduction:
The salt spray corrosion test chamber meets the requirements of GB/T5170.8 Basic Parameter Calibration Method for Environmental Testing Equipment of Electrical and Electronic Products, and can be tested according to GB/T2423.17 Basic Environmental Testing Regulations for Electronic and Electrical Products. It can be used for neutral salt spray testing or acetic acid salt spray testing.
Anhydrous heating salt spray testing machineProduct Overview:
The base of the laboratory is made of 8 # channel steel welded into a mesh frame, which can withstand the weight of the chamber and personnel specimens under horizontal conditions without uneven or cracked bottom surfaces. The indoor and outdoor materials are made of PP material, with a thickness of 12MM. The insulation material is polyurethane foam insulation, which is lightweight, resistant to resistance, and has good heat dissipation performance. The door material is PP material, and the handle is stainless steel material, making it convenient for the test personnel to open the door freely from the enclosed room.
Main technical parameters of the walk-in salt spray chamber:
1. Studio size:2000 mm×3500 mm×3500mm(Width x Depth x Height) (excluding spire)
2. Outer box dimensions:2200mm×4000 mm×4250 mm(Width x Depth x Height)
3. door : Open the door,2000mm×3500mm(Width x Height)
4.Temperature range: 35℃-50℃
5.Temperature fluctuation: ±0.5℃(When unloaded)
6.Temperature deviation degree: ±2℃ (When unloaded)
7.Wen degree ladder Degree: ≤2℃
8.Salt spray settling amount:1-5 ml/h/80cm2adjustable
9.Salt water concentration: 0.5 ~5%adjustable
10.Test time: 0~999 HTheMTheS;How to translate
11.Observation window: 400×500mm(Length x Height)
12.Spray mode: airflow spray, continuous/The gap is arbitrary.
13.Bottom load-bearing capacity: ≥500KG
15.Average working hours:>2000h
16.Average lifespan:>8 years
17.Noise: ≤ 75dB
18.Rated voltage of laboratory:AC(380±38)V 50Hz±0.5Hz