Welcome Customer !

Membership

Help

Shanghai Xiangrun Industrial Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Shanghai Xiangrun Industrial Co., Ltd

  • E-mail

    18317003557@163.com

  • Phone

    18317003557

  • Address

    Room 319, Building B, Greenland, No. 5558 Chuansha Road, Pudong New Area, Shanghai

Contact Now

ULTRAMAT 6 analyzer 7MB2121-0EV00-1AA1

NegotiableUpdate on 01/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

ULTRAMAT 6 analyzer 7MB2121-0EV00-1AA1 $r $n Siemens U23 analyzer, U6 air separation analyzer, O6 magnetic oxygen analyzer, C6 hydrogen analyzer, Siemens chromatography accessories, Siemens process instruments 7ME6910/7ME6920/7ME6110/7ME6140 flowmeter, 7ML5221 ultrasonic level gauge, 6DR locator and other price advantages,

Product Details

ULTRAMAT 6 analyzer 7MB2121-0EV00-1AA1

Arrival Notice

After a large quantity of analyzer and chromatograph accessories arrived last week. This week, 17 new gas analyzers have arrived with pre orders. Our company will contact everyone as soon as possible to ship the goods quickly,

A large number of multi-component small range analyzers are in stock, and orders are accepted at ultra-low discounts. Don't hesitate, boss with orders. Welcome to inquire.

I am pleased to explain the low range and paramagnetic oxygen technology of Siemens' newly launched ULTRAMAT 23 infrared gas analyzer in 2015 I believe everyone is familiar with the ULTRAMAT 23 infrared gas analyzer. Previously, oxygen sensors were electrochemical, but now oxygen sensors can not only achieve electrochemical but also paramagnetic oxygen, which saves us a lot of costs. As we all know, the ULTRAMAT 23 infrared gas analyzer itself is an affordable product under the Siemens brand. In the past, if we wanted to achieve paramagnetic oxygen function, we had to use the ULTRAMAT/OXYMAT 6 infrared/magnetic oxygen gas analyzer, which is much more expensive than the ULTRAMAT 23 infrared gas analyzer itself. Therefore, Siemens' newly launched ULTRAMAT 23 infrared gas analyzer not only solves the paramagnetic oxygen function for customers, but also saves them a lot of costs. There is also an important new feature, the ULTRAMAT 23 infrared gas analyzer certified by T? V can measure CO, NO, SO2, and O2 according to the requirements in TA Luft, with a small allowable range certified by T? V,

7MB2338-1AA00-3NH1

Product

similar images

Gas analyzer ULTRAMAT 23 is used to measure 3 infrared components and oxygen. The 19 inch pull-out device is installed in the cabinet and measures the gas interface 1/4 inch tube. There is no internal measurement gas pump and no isolated gas path. The first and second infrared measurement components are carbon oxide and nitrogen oxide. The small measurement range is used for CO: 0 to 500 VPM. The small measurement range is used for CO: 0 to 2500 VPM. The large measurement range is used for NO: 0 to 500 VPM. The electrochemical oxygen sensor does not occupy auxiliary energy: 230 V AC, 50 Hz. The third measurement component: SO2 concentration range 'S'. Parallel measurement of SO2 and NO2 with ultraviolet photometer. The third measurement component: small measurement sample: 0 to 2500 VPM. 500 vpm large measurement range: 0 to 2500 vpm operating software, documentation in English

List price (excluding tax) Display price
Your unit price (excluding tax) Display price
Service and support (manuals, certifications, Q&A, etc.) download

More images

product
Product Code (Commercial Code) 7MB2338-1AA00-3NH1
Product Description Gas analyzer ULTRAMAT 23 is used to measure 3 infrared components and oxygen. The 19 inch pull-out device is installed in the cabinet and measures the gas interface 1/4 inch tube. There is no internal measurement gas pump and no isolated gas path. The first and second infrared measurement components are carbon oxide and nitrogen oxide. The small measurement range is used for CO: 0 to 500 VPM. The small measurement range is used for CO: 0 to 2500 VPM. The large measurement range is used for NO: 0 to 500 VPM. The electrochemical oxygen sensor does not occupy auxiliary energy: 230 V AC, 50 Hz. The third measurement component: SO2 concentration range 'S'. Parallel measurement of SO2 and NO2 with ultraviolet photometer. The third measurement component: small measurement sample: 0 to 2500 VPM. 500 vpm large measurement range: 0 to 2500 vpm operating software, documentation in English
product family Not provided
Product Lifecycle Management (PLM) PM400: Product announced delisting/will gradually cease supply
PLM expiration date Product discontinuation date: October 18, 2016
Attention

The product order number is incorrect or does not meet the format requirements. Please check

Price data
Price Group/Headquarters Price Group 820
List price (excluding tax) Display price
Your unit price (excluding tax) Display price
Metal coefficient none
Delivery Information
Export Control Regulations ECCN : 3A991X / AL : N
Factory production time 30 days
Net weight (Kg) 12 Kg
Product size (W x L X H) Not provided
Package dimensions Not provided
Measurement of packaging size units Not provided
unit of quantity 1 piece
Quantity per package 1
Other product information
EAN Not provided
UPC Not provided
Product Code 90271010
LKZ FDB / cataloged PA10
product group 4610
Country of Origin France

ULTRAMAT 6 analyzer 7MB2121-0EV00-1AA1