The HIAC 8011 laboratory analysis laser photoresist oil particle counting system has been replaced by the 8011+system
The benefits of choosing HIAC 8011+
-Screen prompts can guide users to complete common sampling operations
*Instrument diagnostic function, with various operations for users * | User prompts for particle sediment and each run deviation | HRLD intelligent sensor service and calibration prompts
-The sample management system ensures the generation of accurate and precise data
The pressurized sample transfer can reduce the influence of bubbles | The integrated vacuum/degassing function can streamline the sample processing flow and improve accuracy | The automated sample process can provide accurate data
-Less steps Increase production volume
One click sampling - results can be generated in 60 seconds | Quickly load over 20 testing methods | Set your own sampling method in 5 steps
-No need to waste time diluting samples and cleaning instruments
No need to dilute high concentration (<425cSt) liquid | Automatic cleaning and rinsing | Sensor contamination alarm can notify you in advance to ensure that you perform cleaning, avoid wasting samples and obtaining bad data
-Eliminate printing and achieve paperless. You can immediately obtain data in PDF or Excel file format
Create specific application reports in PDF or Excel format | Embedded web browser for online viewing and approval of reports | Reports can be exported via USB memory stick or Ethernet
The HIAC 8011 laboratory analysis laser photoresist oil particle counting system has been replaced by the 8011+system
System components and specifications
HIAC 8000A counter host
The 8000A host is a specialized microcomputer system. It receives output electrical pulses from sensors and distributes pulses representing different particle sizes to different channels for counting. The 8000A host has 8 counting channels, meeting the needs of all industrial standards. It has high definition, large LCD screen, 24 thin film operation keys, beautiful appearance, and complete functions. The machine is equipped with an upgradable EPROM memory and can be externally connected to the powerful CountSpec software, which can be used for both batch and online purposes. Five commonly used industrial standards have been pre integrated, and users can also store four additional custom standards as needed. The machine can select up to eight particle size ranges of interest according to user needs, display and print the standard number of particles within these ranges, and automatically display and print the cleanliness level and test results of the samples based on the called standards. During sample testing, the ABS-2 sampler also automatically starts and stops under the control of the counter. All functions are automatically operated through the built-in menu style professional software of the host, and can also be remotely controlled by configuring the HIAC CountSpec software. Users only need to press the START button to quickly and accurately complete the test and obtain the report.
Data input:Thin film keyboard, RS232
Data output:High definition LCD, built-in micro printer, RS232
Overall dimensions:41 wide x 31 deep x 17 high (cm)
Host weight:5 kilograms
HIAC ABS-2 automatic bottle sampler
The function of ABS-2 sampler is to place the sample bottle in a closed container, apply a certain pressure, and accurately press a certain amount of oil sample into the sensor for sensing at a specific flow rate (10-200ml/min, depending on the viscosity of the oil sample). ABS-2 is aesthetically pleasing, sturdy, and durable; Easy to operate, automatic sampling, fully sealed design, avoiding human error and secondary pollution, and capable of pressure sampling volatile oil samples; The sampling volume can be set arbitrarily to reduce repetitive labor; Remove bubbles from liquid samples by vacuuming; By using a magnetic stirrer to uniformly suspend solid particles in the sample, the accuracy and repeatability of the particles can be improved; It can be operated in both manual and automatic modes.
Single sampling quantity:10-120 milliliters, incremental increments of 5 milliliters
Sampling chamber volume and pressure:Zui can fit a sampling bottle that is 20.3 centimeters high and 7.6 centimeters in outer diameter. The maximum pressure is 60psi.
Overall dimensions:32.4 wide x 45.7 deep x 68.6 high (cm)
Sampler weight:20 kilograms
HIAC HRLD-400 Laser Resistance Sensor
Sensors are the most critical unit in the system, sensing the number and size of particles (insoluble solid particles). It adopts the principle of laser light resistance. When each particle passes through the sensing area uniformly illuminated by the laser with the liquid, the particle's obstruction of the laser will generate a voltage pulse proportional to the projected area of the particle on the photodetector. One pulse records the next particle, and the equivalent particle size of this particle can be determined by the height of the voltage pulse.
HAIC's laser liquid sensor has multiple models to choose from, with a measurement particle size range of 0.1-600 microns (depending on the sensor model, see ordering guide).
Ordering Guide
Please select the host, sampler, and sensor model when placing an order:
Main host model: HIAC 8000A standard type Main sampler model:
HIAC ABS-2 standard type, or HIAC SDS high viscosity sampler (maximum sampling viscosity 1800 centipoise)
Main sensor models: