Welcome Customer !

Membership

Help

Shanghai Hengze Technology Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Shanghai Hengze Technology Co., Ltd

  • E-mail

  • Phone

  • Address

    Room 322, Building A, Lane 168, Chengnan Road, Huinan Town, Pudong New Area, Shanghai

Contact Now

Taurus TCA series heat flow

NegotiableUpdate on 03/03
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
No need for energy is the best energy "- Marcel Huber, Environment Minister of Bavaria, Germany, 2011-2014. Protecting the environment, conserving our natural resources, and conserving energy have become increasingly important
Product Details

Not needing energy is the best energy

—— Marcel Huber, Minister of Environment of Bavaria, Germany, 2011-2014


Protecting the environment, preserving our natural resources, and conserving energy are becoming increasingly important. The use of insulation materials and building materials with low thermal conductivity values essentially helps us achieve these goals. These materials help prevent the internal temperature of the building from approaching the external temperature, thereby minimizing energy loss in the building to the greatest extent possible. In this way, the energy required to heat or cool the interior of the building can be greatly reduced.

The thermal conductivity coefficient (lambda, λ) is the characteristic of material thermal conductivity, expressed in W/(m · K) (watts per meter x Kelvin). The lower the thermal conductivity of the material, the better its insulation performance.

The TAURUS product series mainly focuses on measuring the thermal conductivity and insulation performance of buildings, building materials, and insulation materials.

We can provide corresponding equipment based on the following measurement methods:

  • Compliant with ISO 8301Heat flow meter methodequipment
  • Compliant with ISO 8302Protection hot plate methodequipment
  • Compliant with DIN EN ISO 8497Protection heat pipe methodequipment

The choice of equipment depends on the expected application:

Heat flow meter Protection hot plate method/heat pipe method
measure time short long
calibration regularly Annual functional regulation
Application field Quality and Production Control Research and development, reference measurement
measure area According to customer requirements within the corresponding standards and overall physical limitations

Thermal conductivity meter TCA 300 using heat flow method

Thermal conductivity measurement equipment using the heat flow meter method, in accordance with ISO 8301, ASTM C 518, DIN EN 1946-3, EN 12664, EN 12667, and EN 12939.

The TCA 300 series measuring equipment is a compact and sturdy desktop model equipped with an integrated single board computer (SBC) running the Windows 10 operating system, software LAMBDA 2016, and a high-resolution color touch screen that can run in standalone mode.

Numerous interfaces such as RS232, USB, and Gigabit Ethernet enable connection with peripheral devices and fast and convenient transmission of all related data. Direct connection to the printer allows for printing test reports without using other PCs.

Instrument features:

  • Fully insulated test box to avoid external influences
  • Two symmetrically arranged precision heat flow meters
  • Use three different temperature ranges of tap water or circulating coolers for external cooling
  • Electric board lifting mechanism
  • Digital pressure measurement system and digital sample thickness gauge
  • Integrated Single Board Computer (SBC) equipped with 32 GB Solid State Drive (SSD), Windows 10, and Lambda 2016 software
  • 10.1-inch color touch screen
  • Interface: 1 RS232, 5 USB, 1 Gigabit Ethernet

Technical Specifications:

TCA 300 Basic Edition TCA 300 Extended Edition TCA 300 High Temperature Edition
Measurement range* 0.002 – 1.0 W/m·K 0.002 – 1.0 W/m·K 0.002 – 1.0 W/m·K
Sample size (L * W) 100 x 100 –300 x 300 mm 100 x 100 –300 x 300 mm 100 x 100 –300 x 300 mm
Sample thickness (H) 5 – 100 mm 5 – 100 mm 5 – 100 mm
temperature range
cold plate
hot plate
(min./max.)
-20 / +60°C
-10 / +70°C
(min./max.)
-20 / +110°C
-10 / +120°C
(min./max.)
0 / +170°C
10 / +180°C
Chassis size (HxWxD) 620 x 440 x 400 mm 620 x 440 x 400 mm 620 x 440 x 400 mm
power supply 110 – 230 V
50 / 60 Hz
110 – 230 V
50 / 60 Hz
110 – 230 V
50 / 60 Hz
weight 41 kg 41 kg 41 kg

*Depending on the thickness of the sample

Thermal conductivity meter TCA 500 using heat flow method

Thermal conductivity measurement equipment using heat flow meter method, in accordance with ISO 8301, ASTM C 518, DIN EN 1946-3, EN 12664, EN 12667 and EN 12939

The TCA 500 series measuring equipment is a sturdy cabinet style model, particularly suitable for testing thicker samples. Thanks to the single board computer (SBC) integrated with the Windows 10 operating system, software Lambda 2016, and high-resolution color touchscreen display, this device is very user-friendly.

Numerous interfaces such as RS232, USB, and Gigabit Ethernet enable connection with peripheral devices and fast and convenient transmission of all related data. If connected to an external PC, the test results can be analyzed in more depth and a test report can be printed.

Features:

  • A fully insulated (X) or temperature controlled (GX) testing chamber to avoid external influences
  • Two symmetrically arranged precision heat flow meters
  • 2 cooling options for different measurement ranges: internal Peltier or external circulating cooler
  • Electric board lifting mechanism
  • Digital pressure measurement system and digital sample thickness gauge
  • Integrated Single Board Computer (SBC) equipped with 32 GB Solid State Drive (SSD), Windows 10, and Lambda 2016 software
  • 10.1-inch color touch screen
  • Interface: 1 RS232, 2 USB, 1 Gigabit Ethernet

Technical Specifications:

TCA 500 X TCA 500 GX TCA 500 PX TCA 500 PGX
Measurement range* 0.005 - 1.0 W/m·K 0.005 - 1.0 W/m·K 0.005 - 0.5 W/m·K 0.005 - 0.5 W/m·K
Sample size (LxW) 250 x 250 –500 x 500 mm 250 x 250 –500 x 500 mm 250 x 250 –500 x 500 mm 250 x 250 –500 x 500 mm
Sample thickness (H) 10 – 120 mm 10 – 200 mm 10 – 120 mm 10 – 200 mm
temperature range
Cold plate (min./max.)
Hot plate (min./max.)
-20 – +60°C
-10 – +70°C
-20 – +60°C
-10 – +70°C
-5 – +50°C
+5 – +60°C
-5 – +50°C
+5 – +60°C
Chassis size (HxWxD) 179 x 80 x 90 cm 179 x 80 x 90 cm 179 x 80 x 90 cm 179 x 80 x 90 cm
power supply 110 – 230 V
50/60 Hz
110 – 230 V
50/60 Hz
110 – 230 V
50/60 Hz
110 – 230 V
50/60 Hz
weight 186 kg 192 kg 190 kg 196 kg

*Depending on the thickness of the sample