Ship level measurementHigh quality production price quote manufacturer, welcome to consult about liquid level measurement table related issuesThe main technical indicators of the glass plate level gauge are [/hour/]. The external dimension measurement range (installation center distance L) is 300, 500, 800, 1100, 1400, 1700 millimeters [/hour/]. The working pressure is 2.5, 4.0, 6.3 megapascals. 0.6MPa (applicable to R-type), glass plate level gauge can be used to directly indicate the liquid level in sealed containers. It has the advantages of simple structure, intuitive, reliable and durable, but the medium in the container should not be corroded by steel, steel paper and graphite pressure rings. The HG5 glass plate level gauge is produced according to the HG5-1364~1370-80 standards of the former Ministry of Chemical Industry, and is suitable for directly indicating the liquid level of various containers such as towers, tanks, cans, and boxes. The safety steel ball is installed on the upper and lower valves of the instrument. When the glass is accidentally damaged, the steel ball will automatically close the liquid flow channel under the pressure inside the container, preventing the liquid level from flowing out. The valve end of the instrument is equipped with a plug screw, which can be used to sample or discharge residual liquid inside the instrument during maintenance. According to the principle of the connector, the actual height of the liquid level in the container is directly displayed through transparent glass. The instrument is equipped with M27 × 1.5 or ZG3/4 "threaded joints on the upper and lower valves, and is connected to the container through flanges to form a connector. The height of the liquid level in the container can be directly read from the glass plate, and the power and output signals are output through a dual core cable (loop) with 4... 20mA output or digital signal output. The separation integral is optional, and the flap level gauge is also known as a magnetic level gauge. The magnetic column level gauge and the magnetic float level gauge use the working principle of magnetic coupling to flip the plate level gauge product to compensate for the fragility of the glass tube level gauge, which cannot work under high temperature and pressure. The 2100 coalbed methane 2700 series static pressure level gauge (level gauge) is suitable for measuring the level of various media in systems and industries such as petrochemicals, metallurgy, power, pharmaceuticals, water supply and drainage, environmental protection, etc. The installation method is exquisite in structure, simple and flexible in adjustment, and convenient for users to use. Users can choose standard signal output modes such as 4-20mA, 0-5V, 0-10mA, etc. according to their needs. [/hour/] ◆ Good stability, with a zero * stability of up to 0.1% FS/year within the compensation temperature range of 0-70 ℃. The temperature drift is less than 0.1% femtosecond, and within the entire allowable operating temperature range, it is less than 0.3% femtosecond. Explosion proof grade: D Ⅱ BT1-4.

This instrument can be used in conjunction with a resistance inductance converter to directly output resistance value signals or output current value (4-20mA) signals. At the same time, in conjunction with other converters to output voltage signals and their switch signals (the converters are allocated by the company according to customer requirements), remote transmission and control of electrical signals can be achieved. There are multiple options for debugging: using programming modules for debugging (equivalent to analysis and processing instruments), software debugging (software debugging), and HART handheld programmer debugging, making debugging convenient and fast. Explosion proof grade: D Ⅱ BT1-4. The plate level gauge is manufactured according to the original Ministry of Chemical Industry HG5-1364~1370-80 standards and is suitable for directly indicating the liquid level of various media in towers, tanks, cans, boxes, and other containers. The safety steel ball is installed on the upper and lower valves of the instrument. When the glass is accidentally damaged, the steel ball will automatically close the liquid flow channel under the pressure inside the container, preventing the liquid level from flowing out. Installation and maintenance of maglev train level gauges, technical specifications of plate level gauges.

ρ: The density of the liquid to be measured, HG5-227-80 glass tube level gauge, is indicated in the instructions for use, technical specifications, and (1). Remote transmission support instruments should be located near the main pipe of the liquid level gauge and fixed with stainless steel clamps (iron is prohibited); Working pressure: 1.6, 2.5, 4.0, 6.4, 10.0 MPa. Glass plate level gauges can be used to directly indicate the liquid level in sealed containers. They have the advantages of simple structure, intuitiveness, reliability, and durability, but the medium in the container should not be corroded by steel, steel paper, and graphite pressure rings. The HG5 glass plate level gauge is produced according to the HG5-1364~1370-80 standards of the former Ministry of Chemical Industry, and is suitable for directly indicating the liquid level of various containers such as towers, tanks, cans, and boxes. The safety steel ball is installed on the upper and lower valves of the instrument. When the glass is accidentally damaged, the steel ball will automatically close the liquid flow channel under the pressure inside the container, preventing the liquid level from flowing out. The valve end of the instrument is equipped with a plug screw, which can be used to sample or discharge residual liquid inside the instrument during maintenance. According to the principle of the connector, the actual height of the liquid level in the container is directly displayed through transparent glass. The instrument is equipped with M27 × 1.5 or ZG3/4 "threaded joints on the upper and lower valves, and is connected to the container through flanges to form a connector. The height of the liquid level in the container can be directly read from the glass plate.
Liquid level measuring gauge

The sealed electronic module and dual filter pressure compensation system can resist the influence of on-site climate change, with good stability and high accuracy. Its characteristics include steam pressure ≤ 0.6MPa, steam jacket joint: G1/2 'external thread, and glass tube level gauge. It is a direct reading level measuring instrument suitable for on-site detection of liquid levels in common liquid storage equipment in industrial production. It has a simple structure and accurate measurement, making it a traditional on-site liquid level measurement tool. Usually used for direct detection, working temperature:, principle: Magnetic flap level gauge (also known as magnetic float level gauge) is developed based on the principle of buoyancy and magnetic coupling effect. When the liquid level in the tested container rises or falls, the body tube of the magnetic float level gauge also rises and falls. The permanent magnet steel in the float is transmitted to the magnetic column turn indicator through magnetic coupling, driving the red and white column turn indicator to rotate 180 degrees. When the liquid level rises, the turn signal indicator light changes from white to red. When the liquid level drops, the steering column indicator changes from red to white. The red and white connector of the indicator represents the actual height of the liquid level inside the container, thereby achieving clear indication of the liquid level.
Liquid level measuring gauge

The liquid level measuring gauge has a sturdy structure, no moving parts, high reliability, and long service life. The magnetic flap does not allow magnetic substances to approach its periphery. Do not fix the iron wire to the body of the liquid level gauge, otherwise it will affect the normal operation of the magnetic valve and the liquid level gauge will be affected. Installation and use of magnetic flip column level gauge: Firstly, check whether the data requirements of the gauge plate are consistent. Within a circumference of 200 millimeters around the pressure gauge, there must be no excitation iron or other magnetic substances, otherwise it will affect the normal operation of the pressure gauge. A shut-off valve should be installed between the level gauge and the container to cut off the material during maintenance and cleaning. The installation of the vehicle body must be vertical, with a maximum deflection angle of ≤ 3 °. When the measurement range is greater than 4m, the installation of intermediate support points should be added during use. Before putting the level gauge into operation, first open the upper flange gas phase valve, and then slowly open the lower flange liquid phase valve to allow the medium to slowly flow into the steel cylinder. The steering column (disc) can be operated one by one according to the instructions, and the zero level can be adjusted with adjusting screws. Installation instructions: Durable, simple structure, easy installation and maintenance, corrosion-resistant, no need for power supply, explosion-proof.

Ship level measurementSelection point: Choosing the right radar level gauge can ensure better use of the radar level gauge. What type of radar level gauge should be selected based on the physical and chemical properties of the fluid medium being measured? Manufacture the diameter, flow range, lining material, electrode material, and output current of radar instruments. Capable of adapting to the properties of the measured fluid and the requirements of flow measurement, with a sturdy structure, no moving parts, high reliability, long service life, simple structure, easy installation and maintenance, corrosion resistance, no power supply, explosion-proof, magnetic baffle level gauge can be used in various towers, tanks, tank ball descriptors, boilers and other equipment. This series of liquid level gauges can be highly sealed and leak proof, suitable for high temperature, high pressure, and corrosion-resistant situations where the indication clarity is poor and the glass plate (tube) is easily damaged. The entire measurement process of the liquid level gauge has no blind spots, clear display, and a large measurement range. The component level gauge of the magnetic baffle is made of materials such as polytetrafluoroethylene (PTFE), polyvinyl chloride (PVC), polypropylene, and imported parts such as 1Cr18Ni9Ti, 316L, OCr18Ni9Ti, and 1Cr18Ni9Ti, which have excellent reliability and corrosion resistance. Steam jacket joint: G1/2 'external thread, magnetic level gauge installation.