E-mail
m975@163.com
-
Phone
13370059858
-
Address
Floor 2-3, No. 107 Xizha Branch Road, Shanghai
Shanghai Jinggong Industrial Co., Ltd
m975@163.com
13370059858
Floor 2-3, No. 107 Xizha Branch Road, Shanghai
Sartoris Needle Filter
*The replaceable polyethylene (PE) safety cone filter can serve as a rear barrier to prevent liquids and vapors from entering the internal components of the pipette. The standard safety cone filter is suitable for ordinary applications. They are used as additional filters for the same type of work, but do not require frequent replacement. Enhanced safety cone filters are used in radiation work, cell culture, bacteriology, virology, and molecular biology work. The interval for replacing filters depends on the purpose and sample. However, according to research, filters should be replaced daily (50-250 pipettes), and should be replaced immediately in case of excessive aspiration. To ensure user safety, tweezers should be used to replace the filter. The mLINE pipette has a filter cartridge removal design. In addition, wipe the suction cone with 70% ethanol before installing the new filter element.

Sartoris Needle FilterFeatures:
|
·Protect the pipette and sample from contamination
|
|
The main parameters of the Sartorius disposable needle filter are:
number |
material |
feature |
application |
aperture |
Minister -N |
Acetate cellulose membrane, polyether sulfone membrane
|
|
Pre filtration, clarification, and sterilization filtration of aqueous solutions |
0.1μm、0.2μm、0.45μm、0.8μm、1.2μm、5μm |
RC Ministry |
Regenerated cellulose membrane |
PH range 3-12, good hydrophilicity, strong chemical compatibility, tolerance to most organic solvents, extremely low adsorption capacity |
Sample preparation suitable for HPLC and GC |
0.2μm、0.45μm |
Minisart-SRP |
Polytetrafluoroethylene membrane |
PH range: 1-14 |
Suitable for HPLC and GC sample preparation, especially for filtering strong acids, strong bases, and strong organic solvents |
0.2μm、0.45μm |
Minister-NY |
nylon membrane |
Resistant to most organic solvents and alkaline solutions, stable within the pH range of 3-14 |
|
0.2μm、0.45μm |
Minister-HY |
Polytetrafluoroethylene membrane |
|
Sterilization and filtration of gases |
|
Minisart-GF |
fiberglass membrane |
|
Pre filtration of turbid liquids with high particle content |
|
Sadolis filtration series products:
Product Number |
Product Name |
membrane |
aperture |
Filter membrane diameter (mm)/processing capacity |
packaging |
16541----------K |
Minisart ® High throughput sterile |
PES |
0.2 μm |
28 / 100ml |
50 |
16533----------K |
Minisart ® High throughput sterile |
PES |
0.45 μm |
28 / 100ml |
50 |
17597----------K |
Minisart ® NML Aseptic |
SFCA |
0.2 μm |
28 / 100ml |
50 |
17598----------K |
Minisart ® NML Aseptic |
SFCA |
0.45 μm |
28 / 100ml |
50 |
17764--------ACK |
Minisart ® RC25 sterile |
RC |
0.2μm |
25/100ml |
50 |
17845--------ACK |
Minisart ® NY25 Aseptic |
Nylon |
0.2μm |
25/100ml |
50 |
17846--------ACK |
Minisart ® NY25 Aseptic |
Nylon |
0.45μm |
25/100ml |
50 |
17846----------Q |
Ministers ® NY25 |
Nylon |
0.45μm |
25/100ml |
500 |
17575--------ACK |
Minisart ® SRP25 Aseptic |
PTFE |
0.2μm |
25/100ml |
50 |
18052----------D |
Sartolab-P20 sterile |
SFCA |
0.2μm |
64/100ml |
10 |
18053----------D |
Sartolab-P20 sterile |
SFCA |
0.2μm |
64/100ml |
10 |
18056----------D |
Sartolab-P20plus sterile |
SFCA+GF |
0.2μm |
64/100ml |
10 |
18058----------D |
Sartolab-P20plus sterile |
SFCA+GF |
0.2μm |
64/100ml |
10 |
18068----------D |
Sartolab-P20plus sterile |
PES+GF |
0.2μm |
64/100ml |
10 |
18075----------D |
Sartolab-P20 sterile |
PES |
0.2μm |
64/100ml |
10 |
180C1----------E |
Sartolab RF150 Aseptic |
PES |
0.22μm |
18cm2/150ml |
12 |
180C2----------E |
Sartolab RF500 Aseptic |
PES |
0.22μm |
39cm2/500ml |
12 |
180C3----------E |
Sartolab RF1000 Aseptic |
PES |
0.22μm |
62cm2/1000ml |
12 |
180C4----------K |
Sartolab BT150 Aseptic |
PES |
0.22μm |
18cm2/150ml |
48 |
180C5----------E |
Sartolab BT5000 Aseptic |
PES |
0.22μm |
39cm2/500ml |
12 |
180C6----------E |
Sartolab BT1000 sterile |
PES |
0.22μm |
62cm2/1000ml |
12 |
180C7----------E |
Sartolab RF250 Aseptic |
PES |
0.22μm |
24cm2/250ml |
12 |
180C8----------E |
Sartolab RF1000 Aseptic |
PES |
0.1μm |
62cm2/1000ml |
12 |
Medical applications and special sterilization applications
The Sartorius needle filter has a wide range of pore sizes and is an excellent product for liquid clarification and filtration, such as in the preparation of medical drugs and buffer solutions. Needle filters are a good choice for vessels, bioreactors, fermentation tanks, medical tubular systems, etc. that require sterilization and particle removal of air and other gases. Many filters have obtained EU CE certification and have many choices in membrane materials, connectors, and housing materials.
Common membrane materials:
SFCA membrane (acetic acid membrane without detergent): extremely low adsorption. Suitable for protein solutions, buffer solutions, culture media, and other aqueous solutions.
PES membrane (polyethersulfone membrane): low adsorption, acid and alkali resistance. Suitable for aqueous solutions such as culture media and buffer solutions.