SWP-LED series instruments

NegotiableUpdate on 04/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Instrument, Instrumentation, Intelligent Instrument

Product Details

Instrument, Instrumentation, Intelligent Instrument

1SWP-LED series instrumentsIntroduction

  SWP-LED series intelligent instrumentIt is a generation of intelligent instruments developed by our company based on years of manufacturing experience in digital instruments, extensive research on * products, and the characteristics of industrial field applications in China.

  SWP-LED series intelligent instrumentThe centralized use of multiple * technologies greatly improves the stability and reliability of operation.

  SWP-LED series intelligent instrumentThe appearance and structure have been greatly improved on the original basis, bringing greater convenience to users' installation and maintenance.

  SWP-LED series intelligent instrumentAs a detection and control product in industrial process automation systems, it has been widely used in industries such as national defense, steel, electricity, petrochemicals, machinery, pharmaceuticals, textiles, metallurgy, printing and dyeing.

2、 Characteristics of SWP-LED series instruments

1. By adopting higher integration IC chips, SMT surface mount technology, and circuit shielding technology, the instrument has excellent resistance and reliability, and can operate stably in electromagnetic interference environments.

2. By using * input jumper settings, each instrument can achieve various division marks, standard signals, remote pressure signals, and millivolt signals through simple and quick parameter settings.

3. By adopting a modular universal circuit structure, various functional transformations of the instrument can be achieved through simple module combinations, significantly enhancing its versatility and flexibility.

4. Adopting a microcomputer controlled fully automatic digital calibration system, no potentiometer adjustment is required.

5. The appearance of the instrument is beautiful and elegant, and there are various external structures and sizes.

6. The whole machine and movement assembly adopt a snap in structure, which is very easy to maintain and disassemble.

7. Power supply options: AC 220V, 50/60HZ, 90-265V switch mode power supply, or DC 24V power supply.

8. It can be equipped with RS-232/RS-485 or RS-422 communication interfaces, making it convenient to connect with the upper computer to form a control system.

3、 General Technical Parameters of SWP-LED Series Instruments

Usage environment

ambient temperature

0~50℃

relative humidity

≤ 85RH Avoid strong corrosive gases

power supply voltage

Conventional type AC220V+10-15%(50Hz±2Hz)

Special type AC90~260V - Switching power supply DC24V ± 2V - Switching Power Supply

power waste

≤ 6W (powered by AC220V linear power supply)

≤ 6W (powered by AC90-265V switching power supply)

≤ 6W (powered by DC24V switching power supply)

input signal

Analog quantity

Thermocouples: Standard thermocouples - B, S, K, E, J, T, WRe, etc

Resistance: Standard thermistor - Pt10, Pt100, Cu50, Cu100 and other remote pressure resistors, etc

Current: 0-10mA, 4-20mA, 0-20mA, etc. - Input resistance ≤ 250W

Voltage: 0-5V, 1-5V, mV, etc. - Input impedance ≥ 250KW

discrete signal

Pulse signal: waveform - rectangular, sine or triangular wave

Radiance - greater than 4V (or as per user requirements)

Range -0-10KHz (or as per user requirements)

Contact signal: electrical contact input signal

output signal

Analog output

DC 0-10mA (load resistance ≤ 750W)

DC 4-20mA (load resistance ≤ 500W)

DC 0-5V (load resistance ≥ 250KW)

DC 1-5V (load resistance ≥ 250KW)

switch output

Relay control output - relay ON/OFF return differential.

AC220V/3A; DC24/6A (resistive load)

Controllable silicon control output - SCR (thyristor zero crossing trigger pulse) output,

0.5A/ 400V

Solid state relay output - SSR (Solid State Relay Control Signal) output,

5-24V/30mA (voltage not adjustable)

Bidirectional thyristor output - SOT thyristor output, 3A/400V

Communication output

Interface Method - Standard Serial Bidirectional Communication Interface:

RS-485,RS-232C,RS-422 等

Baud rate -300~9600bps, freely set internally

Feed output

DC24V, Load ≤ 30mA

feature

measurement accuracy

± 0.2% FS ± 1 word or ± 0.5% FS ± 1 word

resolution

± 1 word

measurement range

-1999 to 9999 words

display mode

. -1999 to 9999 word measurement value display

. -1999 to 9999 character set value display

Display of working status of light-emitting diode

Method

The control/alarm mode is to bring back the upper or lower limit alarm of the difference

(Users can freely set)

control accuracy

± 1 word

temperature compensation

0-50 ℃ digital temperature automatic compensation

Print control

You can choose to directly connect various types of serial printers

(such as LQ-300K, TPuP series micro printers, etc.), with a printing interface of RS-232C

printing accuracy

Same instrument accuracy

Parameter Settings

Panel touch key numerical setting

Save parameter settings after power failure

Parameter setting value password lock

protection method

Input circuit disconnection alarm (when thermocouple or resistor input)

Alarm output status LED indication

Input over/under range alarm

Automatic reset of power supply voltage under voltage

Automatic reset for abnormal work (Watch Dog)

★ Communication method

Selection code

0

2

4

8

9

contact method

No communication

RS-232

RS-422

RS-485

special specifications

★ Transmission output mode

Selection code

0

2

3

4

5

8

output method

No output

4~20mA

0~10mA

1~5V

0~5V

special specifications

★ Control output mode

Selection code

0

1

2

3

4

5

6

7

8

9

output method

No output

relay

4~20mA

0~10mA

1~5V

0~5V

SCR output

SSR output

special specifications

SOT output

SCR - Zero crossing trigger pulse output of thyristor, SSR - Solid state relay control output, SOT - Bidirectional thyristor output