RT70 Metal Reinforcement Corrosion Tester
|
The RT70 steel corrosion meter (also known as the metal corrosion meter) uses electrochemical measurement methods to measure the degree of corrosion of steel bars in concrete. The potential method and gradient method are used for testing, with reference electrodes, and can automatically detect the ambient temperature. Powerful professional Windows data analysis and processing software. Visually represent test results in the form of graphical images (spectra, contour lines, etc.). According to the GB/T50344-2004 "Technical Standard for Inspection of Building Structures"
Performance characteristics: 1. Two testing methods. The potential method and gradient method are two testing methods that are suitable for different testing sites. 2. Reference electrode for sex. The saturated copper sulfate solution is sealed in the reference electrode, and there is no need to replace the solution before and after testing. The operation process is simple, clean, and pollution-free. 3. Automatically detect the ambient temperature. The instrument contains an automatic temperature measurement module that can automatically test, record, and display the ambient temperature on site without the need for a separate thermometer, making it convenient and fast. 4. The instrument can set the testing date. Save the test date for convenient data management for users. 5. Visually display the test results. We used icons, and the darker the color of the icon, the higher the probability of rusting. During the testing process, Users can visually see areas with severe corrosion. 6. True USB data transfer. Quickly transfer the test data to the computer for further analysis. 7. Powerful professional Windows data analysis and processing software. Representing test results in the form of graphical images (spectra, contour lines, etc.), You can directly generate Word detection reports or import data into Excel, which is convenient and fast.
1. The measurement range is ± 2000mV; 2. The testing accuracy is ± 1mV; 3. Measurement point spacing: 1-99cm can be set; 4. Work environment requirements 5.6 Section 5 alkaline battery, with a power supply time of more than 30 hours. Standard Configuration
Main interface of the host Data processing software
|