Qualification upgrade product: DC high voltage generator 120kV 2mA

NegotiableUpdate on 01/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Three level installation, testing, and maintenance of DC high-voltage generators for sale. Technical parameters: 1. Voltage measurement error: 1.0% (full degree) in one word. 2. Current measurement error: 1.0% (full degree) in one word. 3. Overvoltage setting error: ≤ 1.0%. 4. 0.75 switching error: ≤ 0.5%. 5. Ripple coefficient: ≤ 0.5%. 6. Voltage stability: random fluctuations, power supply voltage variation of 10%, ≤ 0.5%. 7. Working power supply: AC 220V 10

Product Details

1. Smaller in size, lighter in weight, more aesthetically pleasing, more reliable, easy to operate, fully functional, and convenient for outdoor use, it is an ideal and reliable product for the new century.

2. Using technology and process manufacturing, the PWM high-frequency pulse width modulation technology and pulse train logic array modulation are applied. High power IGBT devices are used to increase the frequency using high-frequency technology, with a frequency of up to 100kHz, resulting in higher output high voltage stability and smaller ripple coefficient.

3. According to the maintenance free design, the main components are made of imported technology from countries such as the United States, Germany, and Japan, which are durable and not afraid of continuous short circuit discharge to ground.

4. High precision and accurate measurement. The voltage and current meters are both digital displays with a voltage resolution of 0.1kV and a current resolution of 0.1uA. The voltage meter on the control box directly displays the voltage value applied to the load test sample without the need for an external voltage divider during use, and the wiring is simple. The instrument has high and low voltage ends for measuring leakage current, and the high voltage end is displayed with a circular shielded digital meter, which is not afraid of discharge shock and has good anti-interference performance, suitable for on-site use.

5. The voltage regulation has high stability and smooth voltage regulation across the entire range. The output voltage regulation adopts an imported single multi turn potentiometer, which ensures a smooth boosting process and high adjustment accuracy. It is also designed with coarse and fine adjustment functions. The voltage regulation accuracy is better than 0.1%, the measurement error of voltage and current is less than 1.0%, and the pulsation factor is better than 0.5%.

6. Negative polarity output, zero start, continuously adjustable, with various protection functions such as overvoltage, overcurrent, return to zero, grounding protection, and * disconnection protection. The automatic protection circuit has strong functions, complete and reliable protection, ensuring safe operation. All technical indicators are superior to industry standards and superior to similar products.

7. Added high-precision 75% VDC-1mA function for convenient measurement of zinc oxide lightning arresters. A gentle press does not require calculation. There is a 75% voltage function key on the control box of this instrument. During the lightning arrester test, when the current rises to 1000uA, the 0.75 button is turned on. At this time, the values displayed on the voltmeter and ammeter are 75% of the data. After completion, the boost knob should be immediately returned to the zero position, and the fine adjustment voltage knob should be returned to the zero position. The green button should be immediately pressed to cut off the high voltage and turn off the power switch. Conduct other experiments.

8. The convenient overvoltage setting function adopts a digital dial switch, which can intuitively display the set voltage value, making your operation more flexible and intuitive

The unit of measurement is kV.

9. The double pressure cylinder can be divided into sections for on-site use, which is flexible and convenient. It can be used for multiple purposes and is economical.

10. There are three concealed support feet at the bottom, which increase the stability of the pressure doubling cylinder.

400KV High Frequency DC High Voltage Generator

Specifications

Technical Specifications

60/2

100/2

120/2

160/2

180/2

200/2

250/2

100/200

3/2

200/300

3/2

Other

Level

Output voltage (kV)

60

100

120

160

180

200

250

100/200

200/300

600-800kV and other contracts

Customized.

Output current (mA)

2

2

2

2

2

2

2

3/2

3/2

Output power (W)

120

200

240

320

360

400

500

400

600

Charging current (mA)

3.0

3.0

3.0

3.0

3.0

3.0

3.0

4.5/3.0

4.5/3.0

Chassis weight (kg)

4.3

4.3

4.3

4.3

4.3

4.4

4.5

4.5

8.1

Height of pressure doubling cylinder (mm)

Φ80

×500

Φ80

×620

Φ80

×770

Φ80

×770

Φ110

×770

Φ110

×770

Φ110

×820

Φ110

×800

Φ110

×1350

Double pressure weight (kg)

6.3

6.8

6.8

7.2

7.2

7.2

7.6

7.5

12.6