QL-100 Low Concentration Ozone Aging Test Chamber

NegotiableUpdate on 04/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

QL-100 Low Concentration Ozone Aging Test Chamber $r $n 1. Product Application: It can be used for rubber products such as vulcanized rubber, thermoplastic rubber, cable insulation sheaths, etc. Under static tension or continuous dynamic tension deformation, or under intermittent dynamic tension and alternating static tension deformation, it is exposed to air containing constant ozone concentration and a constant temperature test chamber without light exposure. The samples are tested for a predetermined time to evaluate the ozone aging resistance of rubber from the degree of cracking or other performance changes that occur on the surface of the samples.

Product Details

QL-100 Low Concentration Ozone Aging Test Chamber

1、 Product use: It can be used for rubber products such as vulcanized rubber, thermoplastic rubber, cable insulation sheaths, etc. Under static tension or continuous dynamic tension deformation, or under intermittent dynamic tension and alternating static tension deformation, it is exposed to sealed and unlit air containing a constant concentration of ozone and a constant temperature test chamber. The samples are tested for a predetermined time to evaluate the ozone aging resistance of the rubber by detecting the degree of cracking or other performance changes that occur on the surface of the samples.

2、 Test method

Static tensile test
The standard stipulates that the two ends of the sample should be clamped on a fixture, and a tensile elongation of 20% should be selected. The fixture should be installed on a rotating sample holder with a rotation speed between (20-25) mm/S. The test should be conducted at a temperature of (40 ± 2) ℃, a relative humidity of no more than 65%, and a specified ozone concentration. Check the cracking condition of the sample after the specified time. General selection of ozone concentration (50 ± 5) × 10-8.

Dynamic tensile test:
The standard stipulates that the sample fixture can automatically stretch and reset the sample, with a stretching frequency of 0.5 ± 0.025Hz. The two ends of the sample are clamped on the fixture, and the sample is cyclically stretched from 0 to the maximum elongation. The fixture is installed on a rotating sample holder, with a rotation speed of (20-25) mm/S. At a temperature of (40 ± 2) ℃, a relative humidity of not more than 65%, and a specified ozone concentration, the fixture is cyclically stretched and reset and rotated with the sample holder for testing. After the prescribed time, check the cracking condition of the sample, and generally select an ozone concentration of (50 ± 5) × 10-8;

QL-100 Low Concentration Ozone Aging Test Chamber

3、 Model and parameters

Product Model QL-100 QL-225 QL-500 QL-010
Internal dimensions D × W × Hmm 450×450×500 500×600×750 700×800×900 1000×1000×1000
Dimensions D × W × Hmm 1100×870×1600 1150×1020×1850 1350×1220×2000 1650×1420×2100
temperature range A:0℃~70℃、 B:RT+10℃~70℃(Instructions at the time of ordering)
humidity range A:40%~98%R.H、B:85%~98%R.H
temperature fluctuation ≤±0.5℃
Temperature Uniformity ≤±2℃
temperature deviation ≤±1.5℃
Humidity fluctuation +2、-3%R.H
heating rate 0.7~1.0℃/min
降温速率 Reduce the room temperature to 10 ℃ ≤ 20min/unrestricted
ozone concentration 10-1000pphm (low concentration), 1-500ppm (high concentration)Instructions for ordering
gas flow rate 12~16mm/S
Ozone sample rack Static and dynamic tensile test specimen racks
Sample rack speed 360 degree rotating sample holder (rotation speed 1r/min)
Time setting range 0-9999 hours
Power requirements AC380 (± 10%) V/50HZ three-phase five wire system

4、 Ozone system:
1. The main component of the ozone generator is a silent discharge tube ozone generator (with the characteristics of small noise volume and high purity) with an output control accuracy of ± 10% for 4-20mA
2. Electrode cooling method: air cooling
3. Ozone generation gas source: direct air
4. The ozone detection probe consists of an imported CT electrochemical sensor, housing, electronic circuit board, shielded wire, etc
5. Ozone detection probe output signal: 4-20mA
6. Ozone detection probe collection accuracy: ≤± 5% F.S

5、 Circuit control system:
1. Imported color LCD touch screen controller
2. Accuracy: 0.1 ℃ (display range)
3. Resolution: ± 0.1
4. Temperature sensor: PT100 platinum resistance tester;
5. Control mode: thermal balance temperature regulation mode;
6. The temperature control adopts the coordinated control of the same channel by the P.I.D system
7. Equipped with automatic calculation function, it can reduce the inconvenience caused by manual setting
8. Ozone concentration control adopts imported Siemens PIC programmable module and PLC analog expansion module
9. Display: Equipped with a "4.3-inch" high-definition LCD screen

6、 Installation of equipment:
1. For the convenience of ventilation, operation, and maintenance, there should be a certain amount of space left between the equipment and adjacent items or walls for staff to operate. There should be a space of no less than 1-1.5 meters in the front, back, left, and right of the box.
2. It should be installed in a place without direct sunlight.
3. Install as close to the power supply as possible.
4. The equipment is installed separately in a separate room.
5. The studio should have ventilation facilities to facilitate air exchange at any time.
6. The studio should have a 380V power supply (three-phase five wire) and a source of pure water.
7. In order to stabilize the performance and functionality of the equipment, it should be kept in a working environment with a perennial temperature of 15 ℃~28 ℃ and a relative humidity of no more than 85%.
8. The temperature and humidity of the installation site must not change rapidly.
9. It should be installed on a level ground.