Prominent Sensor DULCOTEST Series
![]() |
| PH value measurement sensor | Redox potential measurement sensor | Conductivity measurement sensor | ||||||||
|
Measuring rangePH value 1-12, 0-12 Installation length:120mm Push screw connector SN6 same core plug and PG13.5 fixed thread (unless otherwise specified) PHE 112 SE 型 Temperature:0~60℃ The biggest work pressure:5mW.C., It is recommended to use it under normal pressure. Main applications:Swimming pools, drinking water from the food industry, and mildly polluted wastewater PHEP 112 SE type Temperature:0~80℃ The biggest work pressure:6 bar Main applications:Pool water, drinking water, electroplating industry, and wastewater with mild pollution in industrial water treatment. PHER 112 SE type Temperature:0~80℃ The biggest work pressure:6 bar Main applications:Municipal and industrial wastewater, drinking water, industrial process water, chemical and paper industries. PHEX 112 SE type Temperature:0~100℃ The biggest work pressure:16 bar (25 ℃) and 6 bar (100 ℃) Main applications:Wastewater treatment, chemical processes, etc. are more effective for heavily polluted media, media with high protein content, and media with high pressure or large pressure changes. PHED 112 SE 型 Temperature:0~80℃ The biggest work pressure:8 bar Main applications:Mild pollution wastewater from drinking water, industrial water treatment, and cooling circulating water. PHEF 012 SE 型 Main applications:Corrosion resistant to hydrofluoric acid liquids, such as wastewater treatment in electronic chips or electroplating industries PHEN 112 SE 型 Glass column potassium chloride, refillable pH electrode. Temperature:It is recommended to use it under normal pressure from 0 to 80 ℃, and an external PE storage container, connecting pipe, and bracket can be attached. Main applications:Wastewater treatment PHEE 112 S 型 Potassium chloride filled glass column PH electrode with sealable filling connector, 3 ceramic separators, and 1 spike glass separator. Temperature:0~60℃ working pressure:Recommended for use under normal pressure Main applications:Food industries such as meat products and dairy products.
DLG111 type pre sampler Can install 2 PG13.5 sensors and 1 1 "sensor. Zui High Operating Temperature:55℃ The biggest work pressure:1 bar can be connected to an 8 × 5mm PE hose or bonded to a DN10 hard pipe. DGM type online sampler Each module can install one sensor, with two types of mounting hole threads: PG13.5 and 25mm. Multiple sensor sheaths can be used in series. Zui High Operating Temperature:60℃ The biggest work pressure:6 bar (30 ℃) 1 bar (60 ℃) 2 bar (using a flow meter) ETS 1P invasive online sampler Used for installing sensors with SN6 plug for conductivity, temperature, pH value, and redox potential, PG13.5 sensor. | Measurement range: -1000~+1000mV Installation length: 120mm Push screw connector, SN6 same core plug, PG13.5 fixed thread. (Unless otherwise specified) PHE-PT-SE 型 Temperature:0~60℃ The biggest work pressure:5mW. C. It is recommended to use it under normal pressure. Main applications:Pool water, food industry water, and wastewater with mild pollution in industrial water treatment. PHEX-PT-SE 型 Temperature:0~100℃ The biggest work pressure:16bar(25℃) 6bar(100℃) Main applications:Suitable for measuring high turbidity wastewater, industrial and municipal wastewater, chemical process water, emulsions and suspensions containing proteins and sulfides. For the selection and use of other parts, please refer to the pH measurement sensor.
Used in conjunction with DULCOMETER or DULCOMARINR controllers, it outputs 4-20mA standard signals and is installed in DLG or DGM online samplers for use. CLE3-Ma-0.5, 2, 10, 20, 50ppm residual chlorine concentration measurement sensor Measuring range0.01~0.5 mg/L,0.02~2.0 mg/L 0.1~10.0mg/L,0.2~20 mg/L0.5~50 mg/L(PH 值范围:5.5~8.0) Main applications:Pool water, drinking water, and process water. CGE2-mA-2, 10ppm Organic Chlorine Concentration Measurement Sensor Measuring range0.02~2.0 mg/L,0.1~10.0 mg/L Main applications:Pool water, drinking water, industrial water, cooling circulating water, and high pH water quality. CTE1-mA-0.5,2,10ppm Total Chlorine Concentration Measurement Sensor Measuring range0.01~0.5 mg/L,0.02~2.0 mg/L0. 1~10.0mg/L Main applications:Pool water, drinking water or industrial process water CDE2-mA-0.5,2,10ppm Chlorine Dioxide Concentration Measurement Sensor Measuring range0.01~0.5 mg/L,0.02~2.0 mg/L0. 1~10.0 mg/L Output signal:4~20 mA Main applications:Drinking water or industrial process water CDP1-MA-2 ppm type dioxide rate concentration measurement sensor (process measurement) Measuring range0.02-2g/mL LPH value range: 5.5-10.5 Output signal:4~20mA Main applications:Water used for bottle washing or processes containing surfactants in the beer and beverage industry.
Measuring range0~20 mg/L(DO1-mA) 0~10mg/L(DO2-mA) Operating Temperature0~50℃ The biggest work pressure:10bar(30℃) Main applications:DO1-mA is mainly used in fish and shrimp farms, large aquariums, and zoos; DO2 mA is used for controlling dissolved oxygen in activated sludge tanks. | Push screw connector, SN6 same core plug, PG13.5 fixed thread. LF 1 FE type Installation length:120mm Measuring range0.01~20mS/cm Operating Temperature0~80℃ The biggest work pressure:16bar Main applications:Cooling water treatment, drinking water, industrial process water, and seawater desalination, etc.
This transmitter can be used to convert the millivolt signals output by the Procter pH measurement sensor, oxidation-reduction potential measurement sensor, and Pt100 temperature sensor into 4-20mA standard signals. The transmitter is connected to the controller in a two-wire system. Provide power to the controller while transmitting standard signals to the controller. PH V1 type PH value transmitter Signal output:4~20mA=-500~+500mV (=PH14.5~PH-1.45) Accuracy:Better than ± 0.1 (normal value is ± 0.07) RH V1 type redox potential transmitter Signal output:4~20mA=0~1000mV precisionBetter than ± 0.5mV (normal value is ± 0.3mV) Pt100 V1 type PT100 temperature transmitter Signal output:4~20mA=-0.5~100℃ Accuracy:Better than ± 0.5 ℃ (normal value is ± 0.3 ℃)
OZE3~mA-2ppm type Measuring range0.02~2.0 mg/L Output signal:4~20mA, Installed in DLG111 or DGM type online sampler Main applications:Swimming pools, drinking water, or other industrial process water treatment.
BRE1-Ma-10 ppm type Measuring range0.1~10 mg/L Output signal:4~20mA, Installed in DLG111 or DGM type online sampler. Main applications:Swimming pool water, cooling circulating water, and seawater.
Measuring range10~200 mg/L(PAA1-Ma-200 ppm) 100~2000mg/L(PPA1-Ma-2000 ppm) Operating Temperature1-45 ℃ maximum working pressure: 3 bar (30 ℃) Main applications:CIP cleaning and rinsing processes are more effective for situations containing anionic box cationic surfactants.
FLE 010 SE type Measuring range0.05~10 mg/L PH value range:5.5~8.5 Temperature:1~35℃ The biggest work pressure:7bar Main applications:Waterworks, preventing dental caries |