E-mail
806981218@qq.com
-
Phone
18005426866
-
Address
No.6 Loushan Branch Road, Licang District, Qingdao City
Qingdao Guorui Liheng Environmental Protection Technology Co., Ltd
806981218@qq.com
18005426866
No.6 Loushan Branch Road, Licang District, Qingdao City
GR-3020 smoke flow velocity detector
Portable smoke velocity detector commonly used in environmental monitoringAs a portable monitoring device, it is widely used in boilers, furnaces, and various exhaust ductsSmoke flow rate, smoke flow rate, standard dry flow rateDynamic pressure, static pressure, and smoke temperatureMeasurement of parameters.
Using the pitot tube method to measure gas flow velocity in pipelines,Can be used for various boilers, industrial furnaces, and exhaust ductsSmoke flow rate, smoke flow rateStandard dry flow rateDynamic pressure, static pressure, and smoke temperatureThe instrument uses imported high-precision sensors for parameter detection, with a 24-hour self drift of less than 0.15Pa, especially suitable for detecting low flow rates.

JJG 518-1998 "Verification Regulations for Pitot Tubes"
GB/T 16157-1996 "Determination of particulate matter and sampling methods for gaseous pollutants in exhaust from stationary sources"
1. Adopting imported high-precision micro differential pressure sensors, the pressure drift within 24 hours is less than 0.15Pa.;
2. The measurement accuracy of flow velocity is high, and the lower limit of determination can reach 0.3m/s;
3. Equipped with a rechargeable lithium battery, it can work continuously for more than 48 hours on a single charge;
4. Handheld measurement monitor, lightweight and portable, easy to operate;
5. Automatically calculate parameters such as average gas flow rate, average pressure, and flue gas flow rate.
6.Equipped with automatic zero point correction and software calibration functions to ensure measurement accuracy;
7. It has the function of setting up smoke ducts, automatically sampling the number of points and measuring the distance between them;
8. Large capacity data storage, capable of storing 800 sets of data files;
9. Wide temperature LCD display with Chinese operating interface;
10. Large size, wide temperature, high brightness color display screen display;
11. It has power failure protection function, and the sampling data is not lost during power failure sampling;
12. Built in Bluetooth module, optional Bluetooth printer for data printing
working principle
Align the pitot tube with the airflow direction, with the negative end facing away from the airflow direction. When the flue airflow passes through the positive and negative nozzles of the pitot tube, a pressure difference will be generated. The microprocessor calculates the static pressure, flow rate, and air volume based on the collected dynamic pressure, total pressure, and smoke temperature signals, and then automatically calculates the * flow rate based on the input values of atmospheric pressure, humidity, pipeline cross-sectional area, and other parameters.

The main technical indicators of the flow velocity detector are detailed in Table 1.
Table 1 Main technical indicators of the detector
technical indicators |
parameter range |
resolution |
accuracy |
Smoke dynamic pressure |
(0~2000) Pa |
0.01Pa |
Not exceeding ±2% |
Smoke static pressure |
(-35~35) kPa |
0.01 kPa |
Not exceeding ± 40 |
flue gas temperature |
(0~600) ℃ |
1 ℃ |
Not exceeding ± 3 ℃ |
atmospheric pressure |
(50~110) kPa |
0.1 kPa |
Not exceeding ± 40 |
Smoke velocity |
(0.3~45) m/s |
0.1 m/s |
Not exceeding ± 50 |
Dimensions (length x width x height) |
190mm×95mm×50mm |
||
Continuous working hours |
≥ 48 hours |
||
power consumption |
About 0.5W |
||
Total weight |
0.6kg |
||