Portable hydrogen sulfide H2S analyzer

NegotiableUpdate on 04/03
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Portable hydrogen sulfide H2S analyzer is used for continuous monitoring of atmospheric or process control, specifically for H2S analysis testing in ppb, ppm to% range

Product Details

Operating principle of portable H2S analyzer

The P1500 series is a portable H2The S analyzer can provide a cost-effective analysis method for process control, air quality, and product quality control. In addition, the analyzer has the characteristics of independence, accuracy, and low maintenance. The instrument adopts dual microprocessor technology,Can provide H based on the principle of non-interference with lead acetate operation2S continuous online analysis.Compact structure, weighing approximately 4.5Kg. Versatile functions,Wide range of measurement (ppb~500ppm),No need for dilution. Regarding H in the atmosphere and process flow2Analyze S and adjust the flow rate with precise flow meters. Then, the sample gas is sent to a lead acetate induction band, which is provided with H through a photodiode detector and an LED light source emitting system2Output ratio of S concentration. This signal is processed through an 18 bit analog-to-digital converter and relevant analysis software to generate a linear 4-20mA output (optional). LCD displays current readings, alarm status, program prompts, fault indications, and other information. The P1500 series is a field validated H2The S analyzer can detect H in the sample gas2S provides continuous quantitative monitoring with minimal maintenance.

Technical parameters of portable H2S analyzer


Power input 110/240V 50/60Hz

Working temperature: 5-50 ℃

Storage temperature: 0~70 ℃

Range from ppb to 500ppm for users

Resolution of 1 ppb

Accuracy within ± 2% of the full range

± 1% of the full range repeatability

± 1% of linear full range

Drift zero

Temperature coefficient 0.01%

Response time<1 second

No interference

Analog output 4-20mA isolated output or analog output

Attachment Options Internal Sampling Pump

Sampling probe and regulator

Volatile emission control

battery case

Portable case

RS232/485

Modem communication

AlphaLCD digital display

Graphics pixels 128 × 64

Optional alarm solid state 30mA 24V

Relay 5A220V

Normally Open

Diagnosis and concentration

Weight approximately 4.5Kg

Size 25.4 high x 30.5 wide x 15.2cm deep