E-mail
2355324315@QQ.com
-
Phone
13701838729
-
Address
www.sale-valve.com
Shanghai Tingyang Self Control Valve Co., Ltd
2355324315@QQ.com
13701838729
www.sale-valve.com
Ting Yang Company'sPneumatic double seat regulating valve, pneumatic three-way regulating valve, ZJZP type pneumatic diversion regulating valve,The pneumatic three-way regulating valve is composed of a multi spring pneumatic diaphragm actuator and a three-way diversion (merging) regulating valve body. Pneumatic thin film actuators have the advantages of low height, light weight, high flow capacity, and easy installation and maintenance. Pneumatic three-way control valve, equipped with electrical valve positioning or pneumatic valve locator, can achieve automatic adjustment and control of process pipeline fluid medium. It is widely used for precise control of process parameters such as pressure, flow rate, temperature, liquid level, etc. of gas, liquid, steam and other media to maintain them at given values. The valve core structure of the pneumatic thin film three-way regulating valve adopts a cylindrical thin-walled window and is guided by the side of the valve core. The valve body is a three-way structure, with one inlet and two outlets (pneumatic three-way diversion control valve) and two inlets and one outlet (pneumatic three-way diversion control valve), to achieve fluid mixing heating or cooling, or uneven fluid diversion, meeting the requirements of different industrial and mining uses. The valve body of the pneumatic diaphragm three-way regulating valve has the advantages of compact structure, light weight, sensitive action, small pressure drop loss, large valve capacity, precise flow characteristics, and easy maintenance.
Pneumatic double seat regulating valve, pneumatic three-way regulating valve, ZJZP type pneumatic diversion regulating valveperformance parameters
| Nominal diameter (DN) | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 | |
| Valve seat diameter (dn) | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 | |
| Rated flow coefficient (KV) | flow divider valve | 6.3 | 8.5 | 13 | 21 | 34 | 53 | 85 | 135 | 210 | 340 | 535 | 800 | 1360 |
| confluence valve | – | – | – | – | – | – | 85 | 135 | 210 | 340 | 535 | 800 | 1360 | |
| Allowable pressure difference (MPa) | 3.5 | 3.2 | 2.2 | 2.2 | 1.4 | 1.38 | 0.94 | 0.61 | 0.51 | 0.36 | 0.2 | 0.19 | 0.13 | |
| Nominal pressure (MPa) | 1.6, 2.5, 4.0, 6.4, 10.0 | |||||||||||||
| Equipped with actuator model | TYA/B-22 | TYA/B-23 | TYA/B-34 | TYA/B-45 | TYA/B-56 | |||||||||
| Rated stroke (mm) | 16 | 25 | 40 | 60 | 100 | |||||||||
| Valve cover form | Standard Type (-17~+250 ℃), High Temperature Type (+250~+450 ℃), Low Temperature Type (-40~-196 ℃), Bellows Sealed Type (-40~+350 ℃) | |||||||||||||
| Cover form | Bolt compression type | |||||||||||||
| sealing packing | Polytetrafluoroethylene packing, flexible graphite packing | |||||||||||||
| valve core type | Dual directional sleeve valve core | |||||||||||||
| flow characteristics | Linearity, equal percentage | |||||||||||||
Pneumatic double seat regulating valve, pneumatic three-way regulating valve, ZJZP type pneumatic diversion regulating valveActuator parameters
| Configure actuator category | TYA/B multi spring membrane actuator | ||||
| executor model | TYA/B-22 | TYA/B-23 | TYA/B-34 | TYA/B-45 | TYA/B-56 |
| Effective area (cm2) | 350 | 350 | 560 | 900 | 1400 |
| Travel distance (mm) | 10. 16 | 24 | 40 | 40, 60 | 100 |
| Spring range (KPa) | 20-100 (standard), 20-60, 60-100, 40-200, 80-240 | ||||
| Membrane material | Ding Qing rubber clip nylon cloth, ethylene propylene rubber clip nylon cloth | ||||
| gas supply pressure | 140~400KPa | ||||
| air source interface | RC1/4″ | ||||
| ambient temperature | -30~+70℃ | ||||
| Can be equipped with accessories | Positioner, air filter pressure reducer, holding valve, travel switch, valve position transmitter, handwheel mechanism, etc | ||||
| mode of action | Gas closed type (B) - valve position open when gas is lost (FO); Pneumatic opening (K) - valve position closed in case of gas loss (FC) | ||||