E-mail
cems2001@163.com
-
Phone
13792457636
-
Address
No. 22 Hechuan Road, Licang District, Qingdao City
Qingdao Laoshan Electronic Instrument Factory
cems2001@163.com
13792457636
No. 22 Hechuan Road, Licang District, Qingdao City
Online monitoring of VOCs in German river wastewater, groundwater, and surface water using TID
Widely used for VOC monitoring in tap water, surface water, and groundwater
Product Description: How to Translate
The water quality VOC online monitoring system developed by Meta in Germany consists of three parts.
The first part is the WSS 3 water quality online sampling system, which is suitable for headspace method and complies with German standards such as DIN 38407-9, DIN 55672, VDI 3897, etc. The tested water sample enters the headspace gasification zone through an automatic injection program, and after a certain temperature headspace process, the sample gas is sent to the subsequent gas chromatography column by the carrier gas.
The second part is the gas chromatography and detector section. Using conventional water quality organic pollutant analysis methods - gas chromatography, volatile and semi volatile organic pollutants in water are analyzed and detected. After the sample gas is sent into the gas chromatography column by the carrier gas, according to the principle of chromatographic separation, various pollutant components in the sample are separated due to different retention times.
Can be equipped with multiple detectors: PID, PID&TID, FID. The PID detector can meet the conventional detection requirements, comply with the TO-15 priority monitoring compound list, and meet the water quality and environmental standards. By combining different gas chromatography systems, monitoring of nearly 300 types of organic pollutants can be achieved. The short detection time can be controlled within 3 minutes.
The third part is the data processing part, including the computer system and A/D conversion part. The computer system is equipped with intelligent software for analyzing and storing data, which includes functions such as gas chromatography analysis; Data processing; Visual display of data; Print records; Automatic conversion of measurement points; Raw data storage; Result storage; Calibration records; Free control parameters; Alarm and monitoring signal output; Can develop data reports with upper and lower limit values; Wait. Convert A/D to TIS-AK 2009.
WSS 3 performs cyclic measurements, with all steps from sampling to monitoring being automated. It can perform single measurement or online analysis. The small cycle of the analysis system is 3 minutes, with four channel injection, and can complete 120 measurement processes for each channel per day.
WSS3 has advantages such as simple instrument operation, small size, light weight, low power consumption, and fast analysis time, playing an important role in water quality and environmental analysis that various industries are concerned about. Widely used for daily monitoring of water quality VOCs, monitoring of polluted areas, and detection of water quality VOCs in polluted areas.
Operation description:
-The system performs cyclic measurement, and all steps from sampling to monitoring are automated, allowing for single measurement or online analysis;
-The small cycle of the analysis system is 3 minutes (benzene), with four channel injection. Each channel can complete 120 measurement processes per day;
-Program control and storage of measurement data;
-The analysis software can store all measurement values on the computer hard drive;
-A data report with upper and lower limit values can be developed.
Main parameters |
parameter range |
size |
19 inch modular chassis |
power supply |
230/240V; 50/60Hz |
carrier gas |
nitrogen |
Headspace temperature |
40℃、60℃、120℃ |
protection level |
IP 20 |
Low detection limit |
0.1ppb |
Pump output power |
(2~5)L/h |
Operating Temperature |
0.5~35℃ |
Measuring principle |
Headspace gas chromatography analysis |
detection unit |
PID detector 10.6eV (optional 11.8eV) |
High water pressure |
1 bar |
Injection tube |
Polytetrafluoroethylene (6 × 4) mm (diameter) |
Scope of Application |
Drinking water, process wastewater, pharmaceutical wastewater |
Total weight |
18.0kg |
System:
WSS3 consists of a programmed gas chromatograph with corresponding detectors and a computer system equipped with intelligent software for analyzing and storing data.
The computer equipped with meta control and analysis software can achieve the following functions:
-Gas chromatography analysis
-Data processing
-Data visualization display
-Print records
-Automatic conversion of measurement points
-Raw data storage
-Result storage
-Calibration record
-Free control parameters
-Alarm and monitoring signal output
Execution standard:
Meets the standards for VOC sampling and analysis in water quality set by the US EPA, ISO, EU, and other relevant organizations
Main purpose:
Industrial wastewater VOC online monitoring; Online monitoring of VOCs in rivers;
Online monitoring of VOCs in drinking water; Online monitoring of VOCs in water plants;
Online monitoring of groundwater VOCs; Vehicle mounted on-site VOC rapid detection;
Online monitoring of VOCs in German river wastewater, groundwater, and surface water using TID