Welcome Customer !

Membership

Help

Jingshi Measurement and Control Technology (Shanghai) Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Jingshi Measurement and Control Technology (Shanghai) Co., Ltd

  • E-mail

    1814382150@qq.com

  • Phone

    02162508650

  • Address

    Room J1478, No. 399 Zhongren Road, Jiading District, Shanghai

Contact Now

Online PH/ORP controller

NegotiableUpdate on 01/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Brief description: The Liquisys M CPM223 online PH/ORP controller adopts a modular design and is widely used. The basic transmission provides simple measurement and alarm functions, and the software and hardware modules for extended functions can be applied to special occasions. If necessary, expansion modules can be used. Update time: July 28, 2017 Visits: 321 Product model: CPM223

Product Details

  • detailed introduction

CPM223Online PH/ORP controllerProduct description

Liquisys M CPM 223/253The transmitter adopts a modular design and is widely used. The basic transmission provides simple measurement and alarm functions, and the software and hardware modules for extended functions can be applied to special occasions. If necessary, expansion modules can be used.

CPM223Online PH/ORP controllerProduct Application

sewage treatment

Neutralization reaction

Detoxification (electroplating)

water treatment

hydrological monitoring

CPM223Performance and advantages

On site installation or disk mounted transmitter

Universal

- pHValue and oxidation-reduction measurement(mVor%)It can be cut off through software switches

Easy to operate

-Reasonable menu style structure, displayed in six languages, making configuration more convenient

-Two line display can simultaneously display measurement values and temperature

-Calibration is simple, with the help ofCALKey implementation for two-point calibration

Use safely

-Overvoltage (lightning) protection, compliant withEN61000-4-5standard

-Manual contact output control

-Rationality testing of calibration

-User defined configuration of alarm contacts and fault currents

Scalable basic units:

•2A or4A contact point is used for:

-Limit contact (also used as temperature)

- P(ID)controller

-Timer for flushing process

-Chemical cleaning

extension package

-Any current output configuration

-Alarm or over start automatic cleaning

-suitable forpHSensor monitoring system for glass electrode and reference electrode

-Probe activity detection

-Special neutralization reaction controller

•HART®orPROFIBUS-PA

The second current output is used for temperature

CPM223Technical Specifications

model

CPM223

CPM253

Reference temperature

25

resolution

PH:0.01PH; ORP:1mV/0.1%;temperature0.1

Display error

PH/ORPmax,Measuring Range0.5%, Temperature:max,Measuring Range1%

signal output

PH/ORPmax,Measuring Range0.75%, Temperature:max,Measuring Range1.25%

repetitiveness

PH:max,Measuring Range0.2%,ORP:max,Measuring Range0.2%

zero point

Glass electrodePH5.0-9.0(nominal value:PH7.00

Antimony electrodePH-1.0-3.0(Nominal value:PH1.00)

ISFETelectrode-500-+500mV

slope

Glass electrode38.00-65.00mV/PH(Nominal value:59.16mV/PH

Antimony electrode25.00-65.00mV/PH(Nominal value:59.16mV/PH

ISFET 38.00-65.00mV/PH(Nominal value:59.16mV/PH

Offset

±2PH,±120mV/±50%,±5

ambient temperature

-10-+55

Storage temperature

-25-+65

CAScertification

passCASUniversal certification, suitable for indoor use

relative humidity

10-90%, without condensation

CPM223Order Information

brand

model

description

Endershausen, GermanyE+H

CPM223/253-PR0005

Glass electrode,230V,contactless

Endershausen, GermanyE+H

CPM223/253-MR0005

Digital electrodes,230V, contactless