Minolta LS-100/LS-110 Brightness Meter from Japan

NegotiableUpdate on 03/16
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Japanese Minolta LS-100/LS-110 Brightness Meter $r $n
Product Details

LS-110

feature

The high portability and handheld design enable measurement under various brightness conditions. The non flowing SLR (single lens reflex) optical system can achieve high-precision measurement. The opening angle is 1/3 °, supporting measurement of extremely small target areas.

purpose

Measure the brightness of CRT, LED, and EL.
Measure the brightness of highways and tunnels
Measure railway system signals
Measure road and airport signals
Measure illuminance and outdoor markings

Specifications

Main specifications

model Luminance meter LS-100 Luminance meter LS-110
type SLR illuminance meter for measuring light source and surface brightness
Opening angle 1/3°
optical system 85mm f/2.8 lens; SLR observation system; Flow factor less than 1.5%
perspective
focus distance 1014mm to infinity
Zui small measurement area Φ14.4mm Φ4.8mm
Photodetector Silicon photocell
Relative spectral sensitivity* CIE spectral luminous efficiency V (λ) deviation within 8% (f1 ')
reaction time FAST: Sampling time: 0.1s, display time: 0.8 to 1.0s; SLOW: Sampling time: 0.4s, display time: 1.4 to 1.6s
Luminance unit: cd/m2Or fL (switchable)
measurement range FAST: 0.001 to 299900cd/m2(0.001 to 87530mL)
SLOW: 0.001 to 49990cd/m2(0.001 to 14590fL)
FAST: 0.01 to 999900cd/m2(0.01 to 291800fL)
SLOW: 0.01 to 499900 cd/m2(0.01 to 145900fL)
accuracy 0.001 to 0.999cd/m2(or fL): ± 2% ± 2 digits of the displayed value
1.000cd/m2(or fL) or above: ± 2% ± 1 digit of the displayed value
0.01 to 9.99cd/m2(or fL): ± 2% ± 2 digits of the displayed value
10.00cd/m2(or fL) or above: ± 2% ± 1 digit of the displayed value
(Measure light source A at an ambient temperature of 20~30 ° C/68~86 ° F)
repetitiveness 0.001 to 0.999cd/m2(or fL): ± 0.2% ± 2 digits of the displayed value
1.000cd/m2(or fL) or above: ± 0.2% ± 1 digit of the displayed value
0.01 to 9.99cd/m2(or fL): ±. 2% ± 2 digits of the displayed value
10.00cd/m2(or fL) or above: ±. 2% ± 1 digit of the displayed value
(Tested object: Light source A)
Temperature/humidity drift Within ± 3% ± 1 digit (displayed value at 20 ° C/68 ° F, not exceeding the temperature/humidity range for use)
calibration mode Minolta Standard/User Selection Standard (switchable)
Color correction factor Set through digital input; Range: 0.001 to 9.999
Reference brightness 1. Set through measurement or digital input
Measurement Mode Luminance; Brightness ratio; Peak brightness or brightness ratio
display screen External: 4-digit LCD with additional indicators
Viewfinder: 4-digit LCD with LED backlight
data communication RS-232C; Baud rate: 4800bps
external control The measurement process can be initiated by an external device connected to the data output terminal
power supply One 9V battery; Power can also be provided through the data printer DP-10
power consumption When the test button is pressed and the viewfinder display screen lights up: an average of 16mA
When the power is turned on and the viewfinder display screen is not lit: an average of 6mA
Temperature/humidity range for use 0-40 ° C, relative humidity below 85% (35 ° C), no condensation allowed
Storage temperature/humidity range -20-55 ° C, relative humidity below 85% (35 ° C), no condensation allowed
size 79×208×150mm
weight 850g, Battery not included
Standard Accessories Lens cap; Eyepiece cover; ND eyepiece filter; 9V battery; box

Specifications are subject to change without prior notice.

*
Equivalent to 2% of the T-1 series specifications.
8% CIE (f1 ') is used for the new version of JIS (1993)