GB 19083-2010 Technical Requirements for Protective Masks |
project |
test method |
main instrument |
remark |
Instruments need to be used in conjunction |
Basic requirements for masks |
Chapter 5.1 |
none |
Visual inspection |
|
nose clip |
Chapter 5.2 |
none |
/ |
|
Mask straps |
Chapter 5.3 |
AI-3000/AI-7000Electronic Material Testing Machine |
The tensile strength of the mask strap and mask body shall not be less than 10N |
Pre treatment constant temperature test chamber |
Preprocessing test chamber |
Sections 5.3.2 and 5.4.2 |
GT-7017-EPre treatment constant temperature test chamber |
-30±3℃~70±3℃ |
|
filtration efficiency |
Chapter 5.4 |
Automatic filtration efficiency tester |
|
|
Airflow resistance |
Chapter 5.4.3.2 |
GT-2626-ACRespiratory comprehensive testing machine |
|
|
Synthetic blood penetration |
5.5chapter |
Synthetic blood penetration tester |
|
Pre treatment with constant temperature and humidity |
YY/T 0691-2008 |
|
Pre treatment with constant temperature and humidity |
5.5.2 |
GT-7005Series pre-treatment constant temperature and humidity test chamber |
|
|
Surface moisture resistance |
GB/T 4745-1997 |
GT-7033Surface Moisture Resistance Tester |
|
|
Microbiological Index |
GB 15979-2002、 |
/ |
|
|
GB/T 14233.2-2005 |
|
|
Residual amount of ethylene oxide |
Chapter 5.8 |
gas chromatograph |
|
|
flame retardant performance |
Chapter 5.9 |
GT-7057-C+Mask Flame Retardant Performance Tester |
|
|
Skin irritation |
GB/T 16886.10-2005 |
/ |
|
|
Tightness |
Appendix B |
none |
|
|
YY/T 0969-2013Disposable mask |
project |
test method |
main instrument |
remark |
Instruments need to be used in conjunction |
appearance |
Chapter 4.1 |
none |
Visual inspection |
|
Structure and Dimensions |
Chapter 4.2 |
none |
Actual wear |
|
nose clip |
Section 4.3 |
none |
Length testing measuring tool |
|
Mask strap (strong) |
Chapter 4.4 |
AI-3000/AI-7000Electronic Material Testing Machine |
The tensile strength of the mask strap and mask body shall not be less than 10N |
Pre treatment constant temperature test chamber |
Bacterial filtration efficiency (BFT) |
Chapter 4.5 (same as YY 0469) |
Need to evaluate whether to purchase externally |
|
|
Ventilation resistance |
Chapter 4.6 |
GT-2626-ACRespiratory comprehensive testing machine |
|
|
Microbiological Index |
Chapter 4.7 |
/ |
|
|
GB 15979-2002 |
|
GB/T 14233.2-2005 |
|
Residual amount of ethylene oxide |
Chapter 4.8 |
gas chromatograph |
|
|
Biological evaluation |
Chapter 4.9 |
/ |
|
|
cytotoxicity |
|
|
Skin irritation |
|
|
Delayed hypersensitivity reaction |
|
|
YY 0469-2004Technical requirements for surgical masks |
project |
test method |
main instrument |
remark |
Instruments need to be used in conjunction |
appearance |
Chapter 5.1 |
none |
Visual inspection |
|
size |
Chapter 5.2 |
none |
Actual wear |
|
nose clip |
Chapter 5.3 |
none |
Length testing measuring tool |
|
Mask straps |
Chapter 5.4 |
AI-3000/AI-7000Electronic Material Testing Machine |
The tensile strength of the mask strap and mask body shall not be less than 10N |
Pre treatment constant temperature test chamber |
Preprocessing test chamber |
Sections 5.5 and 5.6.2 |
GT-7005Series pre-treatment constant temperature and humidity test chamber |
5.5: 21±5℃,85±5%; 5.6.2: 38±2.5℃,85±5%; |
|
Liquid barrier (anti synthetic blood penetration) |
Chapter 5.5.1 |
Need to evaluate whether to purchase externally |
|
|
Liquid barrier (surface moisture resistance) |
GB/T 4745-1997 |
GT-7033Surface Moisture Resistance Tester |
|
|
Bacterial filtration efficiency (BFE) |
Appendix B |
Need to evaluate whether to purchase externally |
|
|
Particle filtration efficiency (PFE) |
Chapter 5.6.2 |
Need to evaluate whether to purchase externally |
|
|
|
|
Gas exchange pressure difference, gas flow rate |
Chapter 5.7 |
Need to evaluate whether to purchase externally |
|
|
flame retardant performance |
Chapter 5.8 |
GT-7057-C+Mask Flame Retardant Performance Tester |
|
|
Microbiological Index |
GB 15979-2002 |
/ |
|
|
GB/T 14233.2-2005 |
|
Residual amount of ethylene oxide |
GB 15980-1995 |
gas chromatograph |
|
|
Appendix G |
|
Skin irritation |
GB/T 16886.10-2000/5.2 |
/ |
|
|
cytotoxicity |
GB/T 16886.5-2003/8.2 |
/ |
|
|
Delayed hypersensitivity reaction |
GB/T 16886.10-2005/7.5 |
/ |
|
|
GB 2626-2019Respiratory protective equipment: self-priming filter type particulate matter respirator |
project |
test method |
main instrument |
remark |
Instruments need to be used in conjunction |
Visual inspection |
Chapter 6.1 |
none |
|
|
Preprocessing (temperature and humidity pretreatment) |
6.2.1 Chapter |
GT-7005 series constant temperature and humidity chamber |
|
|
Preprocessing (Mechanical Strength Preprocessing) |
Chapter 6.2.2 |
Mask filter oscillation test chamber |
|
|
filtration efficiency |
Chapter 6.3 |
Automatic filtration efficiency tester |
|
|
Leakiness |
Chapter 6.4 |
Mask leakage tester |
|
|
Inspiratory resistance |
Chapter 6.5 |
GT-2626-AC respiratory comprehensive testing machine |
|
|
exhalation resistance |
Chapter 6.6 |
|
|
Airtightness of exhalation valve |
Chapter 6.7 |
Breath valve airtightness tester Need to evaluate whether to purchase externally |
|
|
Exhalation valve cover |
Chapter 6.8 |
AI-3000/AI-7000 Electronic * Material Testing Machine |
Corresponding fixtures and tooling are required, 1KN |
|
Dead cavity |
Chapter 6.9 |
Protective mask dead space tester |
|
|
vision |
6.10chapter GB 2890-2009 |
Under the mask * LFY-715 |
|
|
headband |
Chapter 6.11 |
AI-3000/AI-7000 Electronic * Material Testing Machine |
Corresponding fixtures and tooling are required, 1KN |
|
Connections and connecting components |
Chapter 6.12 |
AI-3000/AI-7000 Electronic * Material Testing Machine |
Corresponding fixtures and tooling are required, 1KN |
|
lens |
Chapter 6.13 |
Lens impact testing machine (requires head mold) |
|
|
airtightness |
Chapter 6.14 |
GT-2626-AC respiratory comprehensive testing machine |
|
|
flammability |
Chapter 6.15 |
GT-7057-C+Mask Flame Retardant Performance Tester |
|
|
GB/T 32610-2016Technical specifications for daily protective masks |
project |
test method |
main instrument |
remark |
Instruments need to be used in conjunction |
appearance |
Chapter 6.1 |
none |
visual estimation |
|
Color fastness to friction |
GB/T 29865 |
GT-7034-KTextile friction decolorization testing machine |
|
|
formaldehyde content |
GB/T 2912.1 |
spectrophotometer |
|
|
PH value |
GB/T 7573 |
PH meter |
|
|
Decomposable carcinogenic aromatic amine dyes |
GB/T 17592 |
/ |
|
|
GB/T 23344 |
|
Residual amount of ethylene oxide |
GB/T 14233.1-2008 |
gas chromatograph |
|
|
Inspiratory resistance |
Chapter 6.7 |
GT-2626-ACRespiratory comprehensive testing machine |
|
|
exhalation resistance |
Chapter 6.8 |
GT-2626-AC respiratory comprehensive testing machine |
|
|
The breaking strength of the mask strap and the connection between the mask strap and the mask body |
Chapter 6.9 |
AI-3000/AI-7000Electronic Material Testing Machine |
Cooperate with corresponding fixtures and tooling |
|
Robustness of exhalation valve cover |
Chapter 6.10 |
AI-3000/AI-7000 Electronic * Material Testing Machine |
Corresponding fixtures and tooling are required, 1KN |
|
Microbiological Index |
GB 15979-2002 |
/ |
|
|
vision |
GB 2890-2009 6.8 |
Under the mask * LFY-715 |
|
|
filtration efficiency |
Appendix A |
Automatic filtration efficiency tester |
|
|
Protective effect |
Appendix B |
Particle protection effect testing system gt-2170 |
|
|