MTS Profibus Signal Filter 252916,PROFIBUD, D53 connector for MTS magnetostrictive displacement sensor in the United States:
MTS Profibus Signal Filter 252916(CAN) Installation flange content
Durable and reliable industrial displacement sensors
·Linear measurement, value output
LED indicator diagnostic function
·No contact measurement, no wear and tear
·Ultra high precision, with a resolution of 2 μ m
·Non linearity less than 0.01%
·The repeatability accuracy reaches 0.001%
·Standard DeviceNet bus output
The output format options (a to f) of DeviceNet are selected according to user requirements and controller conditions, and are not determined by MTS company.
2. MTS does not provide extension cables for DeviceNet. Users can purchase connectors and cable wiring on their own in the market, or
Turck and Brad Harrison purchased extension cables with connectors.
1. The shielded wire of the sensor cable must be properly grounded in the control box
2. Extension cables with matching connectors can be provided by third parties. Users can purchase them on the market. Effective travel starting point - after sensing zero zone
Non magnetic bracket (provided by the user)
I RH pressure resistant outer tube size and installation instructions|
The module structure of the RH type housing provides a flexible and easy installation method. It is specifically designed for use in hydraulic systems (350 bar continuous, 690 bar peak) and is particularly suitable for internal installation of hydraulic cylinders.