E-mail
jtkhyq@126.com
-
Phone
13814782169
-
Address
No. 98 Jinsheng East Road, Jintan Economic Development Zone
Jintan District Antou Kehui Instrument Factory
jtkhyq@126.com
13814782169
No. 98 Jinsheng East Road, Jintan Economic Development Zone
Low temperature refrigeration cycle unit -60 ℃~-20 ℃Product Overview:
1. To save water resources, a mixture of water and ethylene glycol can be used for circulating refrigeration, which saves resources; Tight circulation pipeline design to prevent circulating water pollution and prolong the use time of circulating water.
2. Multiple security protections ensure more reliable operation.
3. Compressor, cascade subcooling refrigeration technology.
4. Humanized design, flexible and convenient.
5. Double condensing high-efficiency system.
6. Computer stacked temperature controller, temperature digital display, adjustment unit of 0.1 degrees, PT100 temperature sensor, wide temperature range of -125 degrees to -20 degrees.
7. Adopting supercooling technology to ensure temperature stability at low temperatures.
8. The temperature difference between turning on and off the compressor can be set.
9. Environmental temperature monitoring function to prevent the system from operating in an environment with excessively high temperatures.
10. Multiple fault alarms (over temperature alarm, sensor alarm, high pressure alarm, compressor overheating alarm, liquid level alarm).
11. Power on delay protection; Three level stacked system protector.
12. All components are safely grounded.
13. Adopting a fully enclosed design, there is no water absorption during low-temperature operation, ensuring the purity of the cold and heat transfer medium, preventing ice crystals, and providing the service life of the heat transfer fluid.
14. High performance circulating pump that can ensure continuous operation for 24 hours a day.
15. Adopting plate type cold and heat exchangers to provide heat exchange efficiency.
Low temperature refrigeration cycle unit -60 ℃~-20 ℃
model |
LT-6018 |
LT-6030 |
LT-6062 |
LT-6090 |
LT-60A1 |
LT-60A2 |
|
Temperature control range |
-60℃~-20℃ |
||||||
controller |
LCD display for setting and measuring temperature, touch button input |
||||||
compressor |
American Gulun French Taikang |
||||||
evaporator |
Plate type heat exchanger |
||||||
refrigerant |
R-404A |
||||||
sensor |
PT100 |
||||||
refrigeration capacity |
-20℃ |
0.85kW |
1.45kW |
2.5kW |
3.4kW |
4.8kW |
7.2kW |
-40℃ |
0.7kW |
1.2kW |
2.1kW |
2.8kW |
4kW |
6kW |
|
-55℃ |
0.4kW |
0.6kW |
1.2kW |
1.6kW |
2kW |
3kW |
|
|
Circulating pump flow Quantity and pressure |
Max20L/Min 0.7BAR |
Max20L/Min 0.7BAR |
Max35L/Min 1BAR |
Max35L/Min 1BAR |
Max75L/Min 1BAR |
Max75L/Min 1BAR |
|
Liquid storage capacity |
15L |
20L |
25L |
30L |
35L |
45L |
|
safety protection |
Having self diagnostic function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection device and other safety protection functions. |
||||||
interface dimensions |
DN-15 |
DN20 |
DN20 |
DN20 |
DN20 |
DN-20 |
|
Overall dimensions |
400*600*1050 |
50*680*1350 |
550*680*1450 |
550*680*1550 |
620*680*1650 |
750*750*1750 |
|
weight |
145kg |
185kg |
230kg |
275kg |
340kg |
380kg |
|
power supply |
AC220V 50HZ 2.5kW (Max) |
AC380V 50HZ 3.8kW (Max) |
AC380V50HZ 4.5kW(Max) |
AC380V50HZ 6.5kW (Max) |
AC380V50 8kW (Max) |
AC380V50HZ 10.5kW (Max) |
|
Shell material |
Cold-rolled sheet spray coating |
||||||
Controller selection |
5.7-inch 10 inch color touch screen temperature recording and printing |
||||||
Selection of shell material |
SUS304 |
||||||
Power supply selection |
220V 60HZ three-phase, 440V~480V 60HZ three-phase |
||||||
Spray coating selection |
Teflon |
||||||
Explosion proof optional |
ExdIIBT4 or ExdIICT4 |
||||||