LW Type Vertical Non clogging Sewage Pump Product Overview:
The LW type vertical non clogging sewage pump is developed by introducing foreign * technology and absorbing and transforming it. All performance indicators have reached the standard level of similar products. Due to the use of * single (double) channel impellers, the discharge capacity is strong and it can effectively pass through 5 times the diameter of the pump and solid particles with a diameter of 50% of the pump diameter. The dynamic seal adopts two sets of special hard alloy mechanical seal devices made of cast iron and stainless steel.
The LW type vertical non clogging sewage pump is a single suction volute pump equipped with non clogging and anti winding single (double) large channel impellers, which have good passing capacity.
This series of pumps has two structural forms, one is that the motor is directly coaxial with the pump, and the other is that it is connected by a coupling, and the motor adopts a standard vertical motor. The structural diagram is as follows, and each structural form has two types of base connection forms. One is the inlet horizontal suction, which has a corner function and can be placed at 0 °, 90 °, 180 °, 270 ° according to usage requirements for pipeline connection. The other is the inlet axial suction, which is convenient for vertical installation.

[LW type vertical unobstructed sewage pump] Product features:
1. Adopting a double blade impeller structure greatly improves the ability of pollutants to pass through
2. The mechanical seal adopts a new type of friction pair and operates in the oil chamber at * position;
3. The overall structure is compact, small in size, low in noise, energy-saving *, easy to maintain, and convenient for users to replace;
4. The automatic control cabinet can automatically control the pump's over movement and stop according to the required liquefaction changes, without the need for dedicated personnel to supervise, making it extremely convenient to use;
5. Installation methods can be equipped according to user needs, providing convenience for installation and maintenance, and people can enter the sewage pit without having to do so;
6. Can be used within the design scope while ensuring that the motor does not overload;
7. If the pump is equipped with an outdoor motor, there is no need to build a pump room, and it can be directly installed and used outdoors to save costs;
Structural diagram of LW type vertical unobstructed sewage pump:
serial number |
Component Name |
serial number |
Component Name |
|
1 |
base |
5 |
motor |
|
2 |
pump body |
6 |
spindle |
|
3 |
impeller |
7 |
mechanical seal |
|
4 |
油室 |
8 |
impeller nut
|
LW type vertical non clogging sewage pump Product purpose:
The LW type vertical non clogging sewage pump is suitable for the discharge of severely polluted wastewater in factories and commercial areas, sewage discharge stations in main residential areas, water distribution systems in urban sewage treatment plants, drainage stations in civil air defense systems, water supply equipment in waterworks, sewage discharge in hospitals and hotels, municipal engineering construction sites, mining supporting machines, rural biogas digesters, farmland irrigation and other industries. It can also be used to transport granular sewage and pollutants, as well as clean water and weakly corrosive media.
Performance parameters of LW type vertical unobstructed sewage pump:
Model number |
Caliber |
Traffic volume |
Head lift |
Power |
Rotational speed |
Efficiency |
25LW8-22-1.1 |
25 |
8 |
22 |
1.1 |
2825 |
38.5 |
32LW12-15-1.1 |
32 |
12 |
15 |
1.1 |
2825 |
40 |
40LW15-15-1.5 |
40 |
15 |
15 |
1.5 |
2840 |
45.1 |
40LW15-30-2.2 |
40 |
15 |
30 |
2.2 |
2840 |
48 |
50LW20-7-0.75 |
50 |
20 |
7 |
0.75 |
1390 |
54 |
50LW10-10-0.75 |
50 |
10 |
10 |
0.75 |
1390 |
56 |
50LW20-15-1.5 |
50 |
20 |
15 |
1.5 |
2840 |
55 |
50LW15-25-2.2 |
50 |
15 |
25 |
2.2 |
2840 |
56 |
50LW18-30-3 |
50 |
18 |
30 |
3 |
2880 |
58 |
50LW25-32-5.5 |
50 |
25 |
32 |
5.5 |
2900 |
53 |
50LW20-40-7.5 |
50 |
20 |
40 |
7.5 |
2900 |
55 |
65LW25-15-2.2 |
65 |
25 |
15 |
2.2 |
2840 |
52 |
65LW37-13-3 |
65 |
37 |
13 |
3 |
2880 |
55 |
65LW25-30-4 |
65 |
25 |
30 |
4 |
2890 |
58 |
65LW30-40-7.5 |
65 |
30 |
40 |
7.5 |
2900 |
56 |
65LW35-50-11 |
65 |
35 |
50 |
11 |
2930 |
60 |
65LW35-60-15 |
65 |
35 |
60 |
15 |
2930 |
63 |
80LW40-7-2.2 |
80 |
40 |
7 |
2.2 |
1420 |
52 |
80LW43-13-3 |
80 |
43 |
13 |
3 |
2880 |
50 |
80LW40-15-4 |
80 |
40 |
15 |
4 |
2890 |
57 |
80LW65-25-7.5 |
80 |
65 |
25 |
7.5 |
2900 |
56 |
100LW80-10-4 |
100 |
80 |
10 |
4 |
1440 |
62 |
100LW110-10-5.5 |
100 |
110 |
10 |
5.5 |
1440 |
66 |
100LW100-15-7.5 |
100 |
100 |
15 |
7.5 |
1440 |
67 |
100LW85-20-7.5 |
100 |
85 |
20 |
7.5 |
1440 |
68 |
100LW100-25-11 |
100 |
100 |
25 |
11 |
1460 |
65 |
100LW100-30-15 |
100 |
100 |
30 |
15 |
1460 |
66 |
100LW100-35-18.5 |
100 |
100 |
35 |
18.5 |
1470 |
65 |
125LW130-15-11 |
125 |
130 |
15 |
11 |
1460 |
62 |
120LW130-20-15 |
125 |
130 |
20 |
15 |
1460 |
63 |
150LW145-9-7.5 |
150 |
145 |
9 |
7.5 |
1440 |
63 |
150LW180-15-15 |
150 |
180 |
15 |
15 |
1460 |
65 |
150LW180-20-18.5 |
150 |
180 |
20 |
18.5 |
1470 |
75 |
150LW180-25-22 |
150 |
180 |
25 |
22 |
1470 |
76 |
150LW130-30-22 |
150 |
130 |
30 |
22 |
1470 |
75 |
150LW180-30-30 |
150 |
180 |
30 |
30 |
1470 |
73 |
150LW200-30-37 |
150 |
200 |
30 |
37 |
1480 |
70 |
200LW300-7-11 |
200 |
300 |
7 |
11 |
970 |
73 |
200LW250-11-15 |
200 |
250 |
11 |
15 |
970 |
74 |
200LW400-10-22 |
200 |
400 |
10 |
22 |
1470 |
76 |
200LW400-13-30 |
200 |
400 |
13 |
30 |
1470 |
73 |
200LW250-15-18.5 |
200 |
250 |
15 |
18.5 |
1470 |
72 |
200LW300-15-22 |
200 |
300 |
15 |
22 |
1470 |
73 |
200LW250-22-30 |
200 |
250 |
22 |
30 |
1470 |
71 |
200LW350-25-37 |
200 |
350 |
25 |
37 |
1980 |
75 |
200LW400-30-55 |
200 |
400 |
30 |
55 |
1480 |
70 |
250LW600-9-30 |
250 |
600 |
9 |
30 |
980 |
74 |
250LW600-12-37 |
250 |
600 |
12 |
37 |
1480 |
78 |
250LW600-15-45 |
250 |
600 |
15 |
45 |
1480 |
75 |
250LW600-20-55 |
250 |
600 |
20 |
55 |
1480 |
73 |
250LW600-25-75 |
250 |
600 |
25 |
75 |
1480 |
73 |
300LW800-12-45 |
300 |
800 |
12 |
45 |
980 |
76 |
300LW500-15-45 |
300 |
500 |
15 |
45 |
980 |
70 |
300LW800-15-55 |
300 |
800 |
15 |
55 |
980 |
73 |
300LW600-20-55 |
300 |
600 |
20 |
55 |
980 |
75 |
300LW800-20-75 |
300 |
800 |
20 |
75 |
980 |
78 |
300LW950-20-90 |
300 |
950 |
20 |
90 |
980 |
80 |
300LW1000-25-110 |
300 |
1000 |
25 |
110 |
980 |
82 |
350LW1100-10-55 |
350 |
1100 |
10 |
55 |
980 |
84.5 |
350LW1500-15-90 |
350 |
1500 |
15 |
90 |
980 |
82.5 |
350LW1200-18-90 |
350 |
1200 |
18 |
90 |
980 |
83.1 |
350LW1100-28-132 |
350 |
1100 |
28 |
132 |
740 |
83.2 |
350LW1000-36-160 |
350 |
1000 |
36 |
160 |
740 |
78.5 |
400LW1500-10-75 |
400 |
1500 |
10 |
75 |
980 |
82.1 |
400LW2000-15-132 |
400 |
2000 |
15 |
132 |
740 |
85.5 |
400LW1700-22-160 |
400 |
1700 |
22 |
160 |
740 |
82.1 |
400LW1500-26-160 |
400 |
1500 |
26 |
160 |
740 |
83.5 |
400LW1700-30-200 |
400 |
1700 |
30 |
200 |
740 |
83.5 |
400LW1800-32-250 |
400 |
1800 |
32 |
250 |
740 |
82.1 |
500LW2500-10-110 |
500 |
2500 |
10 |
110 |
740 |
82 |
500LW2600-15-160 |
500 |
2600 |
15 |
160 |
740 |
83 |
500LW2400-22-220 |
500 |
2400 |
22 |
220 |
740 |
84 |
500LW2600-24-250 |
500 |
2600 |
24 |
250 |
740 |
82 |
Performance spectrum of LW type vertical unobstructed sewage pump:
Installation diagram of LW type vertical unobstructed sewage pump:

Installation dimension diagram of LW type vertical unobstructed sewage pump:

【 LW type vertical unobstructed sewage pump 】 Fault causes and troubleshooting methods:
Fault phenomenon |
Root Cause Analysis |
Exclusion Method |
|
insufficient traffic
Or no water will come out |
1. Impeller rotation error 2. Is the valve open and intact 3. The pipeline impeller is blocked 4. Head too high 5. The density of the pumping medium is relatively high 6. Damaged sealing ring |
1. Adjust the rotation direction of the impeller 2. Check, repair, and eliminate 3. Clean up debris 4. Change the pump or reduce the head 5. Dilute with water to reduce concentration 6. Replace |
Unstable operation |
1. Unbalanced impeller 2. Bearing damage |
1. Send to the manufacturer for replacement or calibration 2. Replace |
The pump cannot start |
1. Lack of phase 2. Impeller stuck 3. Stator winding burnt out |
1. Check electrical appliances and circuits, and repair them 2. Remove debris 3. Repair and replace the winding |
excessive current |
1. Low working voltage 2. Pipeline and impeller are obstructed 3. The height or viscosity of the liquid being pumped is high 4. Using a low head |
1. Adjust the working voltage 2. Clean up blockages in pipelines and impellers 3. Change density or viscosity 4. Reduce flow and increase head |
Insufficient pressure |
1. Mechanical seal damage or leakage 2. Cable damage |
1. Replace 2. Replace |