Welcome Customer !

Membership

Help

Zhejiang Yongjiu Pump Industry Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Zhejiang Yongjiu Pump Industry Co., Ltd

  • E-mail

    87008636@qq.com

  • Phone

    18968765150

  • Address

    No. 11 Chuangye Road, Longqiao Industrial Zone, Oubei Town, Yongjia County, Zhejiang Province

Contact Now

GW type vertical pipeline sewage pump

NegotiableUpdate on 01/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The GW type vertical pipeline sewage pump is easy to install and has a wide range of applications. It can be used as a general pipeline pump for pressurized water supply in high-rise buildings, as well as for transporting sewage containing granular fibers. In addition to transporting sewage, it is also suitable for use as a drainage pump, filtration flushing condensation circulation pump, etc. This series of pumps adopts an impeller structure and a new mechanical seal, which can effectively transport solids and long fibers. Compared with traditional impellers, the impeller of this pump adopts a single channel or double channel form, which is similar to a curved pipe with the same cross-sectional size and has very good flow characteristics. Coupled with a reasonable volute chamber, the pump has high efficiency. The impeller has undergone dynamic and static balance tests, which enables the pump to operate smoothly

Product Details

[GW type vertical pipeline sewage pump] Product introduction:

The GW type vertical pipeline sewage pump is easy to install and has a wide range of applications. It can be used as a general pipeline pump for pressurized water supply in high-rise buildings, as well as for transporting sewage containing granular fibers. In addition to transporting sewage, it is also suitable for use as a drainage pump, filtration flushing condensation circulation pump, etc. This series of pumps adopts an impeller structure and a new mechanical seal, which can effectively transport solids and long fibers. Compared with traditional impellers, the impeller of this pump adopts a single channel or double channel form, which is similar to a curved pipe with the same cross-sectional size and has very good flow characteristics. Coupled with a reasonable volute chamber, the pump has high efficiency and the impeller has undergone dynamic and static balance tests, making the pump operate without vibration.

Model meaning of GW type vertical pipeline sewage pump:

[GW type vertical pipeline sewage pump] Product features:

1. The pump and motor are directly connected and coaxial, belonging to the electromechanical integration product, with a compact structure and stable performance.
2. The design of anti clogging hydraulic components for large flow channels greatly improves the ability of pollutants to pass through, effectively passing through 5 times the fiber material of the pump diameter and solid particles with a diameter of about 50% of the pump diameter.
3. Reasonable design, reasonable matching motor, high efficiency, low noise, energy-saving *.
4. The mechanical seal adopts hard and wear-resistant tungsten carbide, which has the characteristics of durability and wear resistance, and can ensure the safe and continuous operation of the pump for more than 8000 hours.
5. The pump is a vertical structure, with the inlet and outlet centerlines on the same horizontal line, and the inlet and outlet flange specifications are the same, making installation and disassembly very convenient.
6. Small footprint, no need to build a computer room, can save a lot of infrastructure costs; By adding protective covers to the fan blades of the motor, the entire machine can be operated outdoors.

【 GW type vertical pipeline sewage pump 】 Usage conditions:

A. The operating environment temperature of GW type pipeline sewage pump is ≤ 40 ℃, and the humidity is ≤ 95%; Altitude ≤ 1000 meters.
B、 The medium temperature shall not exceed 60 ℃, and the medium density shall be 1-1.3kg/dm3.
C、 The range of use for cast iron material is from pH 5 to 9.
D、 Stainless steel material can be used with general corrosive media.
E、 The altitude of the usage environment should not exceed 1000 meters. If it exceeds the above conditions, it should be mentioned when placing an order to provide you with more reliable products.
Note: If the user has special requirements for temperature, medium, etc., please specify the detailed information of the conveying medium when ordering, so that our unit can provide more reliable products.

[GW type vertical pipeline sewage pump] Product use:

1. The discharge of severely polluted wastewater from factories and commercial units.
2. Urban sewage treatment plant discharge system.
3. Sewage drainage system in residential areas.
4. Wastewater discharge from hospitals, hotels, and high-rise buildings.
5. Subway, basement, civil air defense system drainage station.
6. Discharge of slurry in municipal engineering and construction sites.
7. The water supply system of water companies and factories.
8. Wastewater discharge from breeding farms or rural biogas digesters, irrigation of farmland.
9. Exploration of mines and supporting equipment for water treatment.
10. Suitable for water supply and drainage in hydraulic engineering.

Structural diagram of GW type vertical pipeline sewage pump:

Performance parameters of GW type vertical pipeline sewage pump:

model

caliber

traffic

head

speed

Motor power

efficiency

mm

m3/h

M

r/min

kw

%

25-8-22-1.1

25

8

22

2900

1.1

45

32-12-15-1.1

32

12

15

2900

1.1

40-15-15-1.5

40

15

15

2900

1.5

54

40-15-30-2.2

40

15

30

2900

2.2

54

50-20-7-0.75

50

20

7

2900

0.75

51

50-10-10-0.75

50

10

10

2900

0.75

52

50-20-15-1.5

50

20

15

290

1.5

53

50-15-25-2.2

50

15

25

2900

2.2

54

50-18-30-3

50

18

30

2900

3

55

50-40-15-4

50

40

15

2900

4

55

50-25-32-5.5

50

25

32

2900

5.5

55

50-20-40-7.5

50

50

20

2900

7.5

58

65-25-15-2.2

65

25

15

2900

2.2

50

65-37-13-3

65

37

13

2900

3

57

65-25-30-4

65

25

30

2900

4

61

65-30-40-7.5

65

30

40

2900

7.5

56

65-35-50-11

65

35

50

2900

11

45

65-35-60-15

65

35

60

2900

15

65

80-60-13-5.5

80

60

13

2900

5.5

67

80-40-7-2.2

80

40

7

1450

2.2

59

80-43-13-3

80

43

13

2900

3

70

80-40-15-4

80

40

15

2900

4

61

80-65-25-7.5

80

65

25

2900

7.5

63

100-80-10-4

100

100

10

1450

4

65

model

caliber

traffic

head

speed

Motor power

efficiency

mm

m3/h

M

r/min

kw

%

100-110-10-5.5

100

110

10

1450

5.5

65

100-100-15-7.5

100

100

15

1450

7.5

68

100-80-20-7.5

100

80

20

1450

7.5

65

100-100-25-11

100

100

25

1450

11

70

100-100-30-15

100

100

30

1450

15

65

100-100-35-18.5

100

100

35

1450

18.5

68

125-130-15-11

125

130

15

1450

11

72

125-130-20-15

125

130

20

1450

15

75

150-145-9-7.5

150

145

9

1450

7.5

76

150-180-15-15

150

180

15

1450

15

69

150-180-20-18.5

150

180

20

1450

18.5

72

150-180-25-22

150

180

25

1450

22

78

150-130-30-22

150

130

30

1450

22

78

150-180-30-30

150

180

30

1450

30

78

150-200-30-37

150

200

30

1450

37

73

200-300-7-11

200

300

7

980

11

66

200-250-11-15

200

250

11

1450

15

64

200-250-15-18.5

200

250

15

1450

18.5

73

200-400-10-22

200

400

10

1450

22

75

200-400-13-30

200

400

13

14501

30

76

200-300-15-22

200

300

15

1450

22

76

200-250-22-30

200

250

22

1450

30

71

200-350-25-37

200

350

25

1450

37

71

200-400-30-45

200

400

30

1450

45

74

model

caliber

traffic

head

speed

Motor power

efficiency

mm

m3/h

M

r/min

kw

%

250-600-9-30

250

600

9

980

30

78

250-600-12-37

250

600

12

1450

37

76

250-600-15-45

250

600

15

1450

45

73

250-600-20-55

250

600

20

1450

55

73

250-600-25-75

250

600

25

1450

75

71

300-800-12-45

300

800

12

980

45

74

300-480-15-45

300

480

15

1450

45

66

300-800-15-55

300

800

15

1450

55

73

300-600-20-55

300

600

20

1450

55

73

300-800-20-75

300

800

20

1450

75

75

300-950-20-90

300

950

20

1450

90

76

300-1000-25-110

300

1000

25

1450

110

76

300-1100-10-55

300

1100

10

1450

55

73

350-1500-15-90

350

1500

15

740

90

87

350-1200-18-90

350

1200

18

980

90

85

350-1100-28-132

350

1100

28

980

132

84

350-1000-36-160

350

1000

36

980

160

84

400-1760-7.5-55

400

1760

7.5

980

55

83

400-1500-10-75

400

1500

10

980

75

86

400-2000-13-110

400

2000

13

980

110

84

400-2000-15-132

400

2000

15

980

132

83

400-1700-22-160

400

1700

22

980

160

83

400-1500-26-160

400

1500

26

980

160

84

model

caliber

traffic

head

speed

Motor power

efficiency

mm

m3/h

M

r/min

kw

%

400-1700-30-200

400

1700

30

980

200

86

400-1800-32-250

400

1800

32

980

250

82

500-2500-10-110

500

2500

10

740

110

85

500-2600-15-160

500

2600

15

740

160

84

500-2400-22-220

500

2400

22

740

220

85

500-2650-24-250

500

2650

24

740

250

85

Performance spectrum of GW type vertical pipeline sewage pump:

Installation dimension diagram of GW type vertical pipeline sewage pump:

Installation and use of GW type vertical pipeline sewage pump:

Firstly, check if the external fasteners have become loose during transportation.
2. Check if the power supply voltage meets the requirements of the motor nameplate.
3. Connect the power and try to turn it on to see if the impeller rotates in the direction indicated on the pump. If the direction is reversed, simply swap any two-phase wires in the cable. During the test run, the time should not be too long to avoid burning out the seal.
4. Install the pump and start it up for operation. Can install the pump foot screws.

Inspection and maintenance of GW type vertical pipeline sewage pump:

1. Before using the pump, the insulation resistance of the motor winding to the casing should be checked. If it is lower than 0.5 megaohms, the stator must be dried and the insulation resistance should be increased before use.
If the gap between the impeller and the oil seal at the inlet of the pump body exceeds 2mm, the wear-resistant oil seal should be replaced.
When there is water leakage in the pump seal, the seal should be replaced in a timely manner. When replacing, the static seal should be installed flat and solid first, and then the dynamic seal should be sealed on the shaft.
4. When replacing the impeller, use a puller to pull it out, and do not use a hammer to strike forcefully to avoid damaging the shaft alignment.

Common causes of faults in GW type vertical pipeline sewage pump

1. No water output, heavy and high particle size of the liquid being pumped; Blockage of liquid flow channel; Wrong impeller direction; The rod material is sucked into the impeller and gets stuck; The height of the pipeline outlet exceeds the rated head height.
2. Insufficient flow and low head. Low voltage, wrong impeller direction, or worn wear-resistant seal; The heavy particle size of the liquid is too high.
3. Low insulation resistance, humid surrounding environment, and severe mechanical seal leakage.

GW type vertical pipeline sewage pumpRelated products:
CQ series stainless steel magnetic pump (flange interface) CQ series stainless steel magnetic pump (threaded connection) CQ-F series engineering plastic magnetic pump (flange interface) CQ-F series engineering plastic magnetic pump (threaded or inserted tube)
CQB series stainless steel magnetic pump (304 316 316L) CQB-G series high-temperature magnetic pump (air-cooled/water-cooled) CQB-G series high-temperature insulation magnetic pump (air-cooled/water-cooled insulation jacket) CQB-F series fluorine lined plastic magnetic pump
IMF series alloy lined fluorine corrosion-resistant magnetic pump (fully lined with PTFE alloy) CQB-L series vertical pipeline magnetic pump ZCQ series self-priming magnetic pump CWB series vortex magnetic pump
MP series plastic miniature magnetic circulation pump QBY series pneumatic diaphragm pump (cast iron thread) QBY series pneumatic diaphragm pump (stainless steel flange interface) QBY series pneumatic diaphragm pump (aluminum alloy threaded interface)
QBY series pneumatic diaphragm pump (engineering plastic thread interface) QBY-F series pneumatic diaphragm pump (fully lined PTFE flange interface) QBK series pneumatic diaphragm pump (stainless steel/aluminum alloy) QBK series pneumatic diaphragm pump (cast iron)
DBY series electric diaphragm pump (cast iron/stainless steel) DBY series electric diaphragm pump (lined with PTFE) DBY series electric diaphragm pump (speed regulating motor) IH series stainless steel chemical centrifugal pump
IHF type fluoroplastic centrifugal pump FSB type fluoroplastic alloy centrifugal pump UHB-ZK corrosion-resistant and wear-resistant mortar pump FS type fiberglass centrifugal pump
S-type fiberglass centrifugal pump SL type vertical fiberglass pipeline pump GBF ZCQ type self-priming magnetic pump
ZW type self-priming non clogging sewage pump ZX series horizontal self-priming centrifugal pump JMZ stainless steel self-priming pump (wine pump) FPZ type reinforced polypropylene self-priming pump
CYZ-A self-priming centrifugal oil pump G-type single screw pump I-1B thick slurry pump LQ3G Three Screw Pump (Insulated Asphalt Pump)